===================== Product Identification =====================
MSDS NAME:ARCOJET FUEL A.
NIIN:00-359-2026
MSDS Number: BGXCV
=== Responsible Party ===
Company:ARCO PETROLEUM PRODUCTS DIV OF ATANTIC RICHFIELD
Address:515 S. FLOWER ST
City:LOS ANGLES
State:CA
ZIP:90071-2201
Info Phone Num:213-486-8258
Emergency Phone Num:312-210-3000
CAGE:3T432
=== Contractor Identification ===
Company:ARCO PETROLEUM PRODUCTS COMPANY
Address:515 SOUTH FLOWER STREET
Box:City:LOS ANGELES
State:CA
ZIP:90071
Country:US
Phone:312-210-3000(CHEMTREC 800-424-9300)
CAGE:3T432
Company:ARCO PRODUCTS CO DIV OF ATLANTIC RICHFIELD CO
Address:333 S HOPE ST
Box:512570
City:LOS ANGELES
State:CA
ZIP:90071-0570
Country:US
Phone:213-486-0773/800-322-2726 INFO
CAGE:9V333
============= Composition/Information on Ingredients =============
Name:JET FUEL A (CAS NO ASSIGNED BY MFR,RTECS BY HMIS)
CAS:8008-20-6
RTECS #:SE7548500
Fraction by Wt: 100%
Other REC Limits:HMIS:100 PPM/5 MG/M3
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS A MILD IRRITANT. MOST
HAZARDOUS EXPOSURE IS TO AIRBORN MIST OR OTHER ASPIRATION OF LIQUID
INTO LUNGS.PROLONGED/REPEATED OVEREXPOSURE MAY CAUSE LIVER OR
KIDNEY DAMAGE.
Explanation of Carcinogenicity:API HAS DONE STUDIES INDICATING THAT
REPEATED OVER EXPOSURES MAY CAUSE CANCER IN MICE.
Effects of Overexposure:EYE:MILD IRRITATING. SKIN:DRYING,DEFATTING WITH
PROLONGED/REPEATED CONTACT.
INHALED:HEADACHE,NAUSEA,CONFUSION,DROWINESS. ASPIRATION OF LIQUID
MAY CAUSE CHEMICAL PNEUMONITIS.INGESTED:G/I IRRITATION,NAU
SEA,POSSIBLE VOMITING.
Medical Cond Aggravated by Exposure:NONE EXPECTED
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:REMOVE CONTAMINATED
CLOTHING (LAUNDER BEFORE REUSE) AND THOROUGHLY WASH AREA OF CONTACT
WITH SOAP AND WATER. INHALED:REMOVE FROM EXPOSURE. RESUSCITATE OR
GIVE OXYGEN IF NEEDED THEN GET MEDICAL ATTENTION. INGESTED:DO NOT
INDUCE VOMITING. GET MEDICAL ATTENTION IF ANY IRRITATION PERSISTS
OR IS SEVERE,GET MEDICAL CARE.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:130F/54C
Autoignition Temp:Autoignition Temp Text:410F
Lower Limits:0.7
Upper Limits:5.0
Extinguishing Media:FOAM,CARBON DIOXIDE,DRY CHEMICAL,WATER FOG.WATER
MAY BE INEFFECTIVE AND MAY SPREAD FIRE IF IMPROPERLY USED.
Fire Fighting Procedures:USE SELF CONTAINED BREATHING
APPARATUS,ESPECIALLY IN ENCLOSED AREAS. WATER SPRAY MAY BE USED TO
COOL FIRE EXPOSED CONTAINERS AND EQUIPMENT.
Unusual Fire/Explosion Hazard:WHEN HEATED SUFFICIENTLY,VAPORS MAY FORM
EXPLOSIVE MIXTURES WITH AIR. SATURATED NEWSPAPERS RAGS,ETC MAY
UNDERGO SPONTANEOUS COMBUSTION.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE IGNITION SOURCES. USE APPROPRIATE
PROTECTIVE EQUIPMENT. CONTAIN KEAK. PREVENT LEAK FROM ENTERING
SEWER,WATER WAY,ETC. RECOVER AS LIQUID.REPORT SPILL IF APPROPRIATE.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL AREA AWAY FROM OXIDIZERS
AND IGNITION SOURCES. DETACHED STORAGE PREFERRED. GROUND CONTAINERS
DURING TRANSFER.
Other Precautions:"EMPTY" CONTAINERS MAY CONTAIN RESIDUE AND/OR FUMES
WHICH ARE EXPLOSIVE.DO NO CUT,WELD,ETC.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT EXPECTED TO BE NECESSARY. USE NIOSH/MSHA
RESPIRATOR IF PRODUCT IS MISTED OR IF TLV/PEL IS EXCEEDED.
Ventilation:USE LOCAL EXHAUST TO MAINTAIN EXPOSURE BELOW TLV/PEL IF
NORMAL ROOM VENTILATION IS IN SUFFICIENT.
Protective Gloves:RUBBER,PLASTIC,OR OTHER IMPERVIOUS
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES.
Other Protective Equipment:USE IMPERVIOUS CLOTHING TO PROTECT FROM
PROLONGED/REPEATED CONTACT.
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT.
Supplemental Safety and Health
MSDS NO APPC 463 CO I.D. 1024910249.
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:325-572A
Melt/Freeze Pt:M.P/F.P Text:-40F/-40C
Vapor Pres:0.1 PSIA
Vapor Density:6
Spec Gravity:0.81
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR,COLORLESS TO AMBER LIQUID, KEROSENE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT,IGNITION SOURCES
Hazardous Decomposition Products:CARBON DIOXIDE,CARBON MONOXIDE
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
INCINERATION IS RECOMMENDED FOR DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|