===================== Product Identification =====================
MSDS NAME:HELIUM
NIIN:00-169-0789
MSDS Number: BHCZP
=== Responsible Party ===
Company:AIR PRODUCTS AND CHEMICALS, INC.
Address:NA
Box:538
City:ALLENTOWN
State:PA
ZIP:18195
Country:US
Info Phone Num:215-481-4911
Emergency Phone Num:1-800-523-9374 IN PA:1-800-322-9092
CAGE:00742
=== Contractor Identification ===
Company:AIR PRODUCTS AND CHEMICALS INC
Address:7201 HAMILTON BLVD
Box:City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Phone:800-345-3148/ 800-752-1597
CAGE:00742
Company:OXYGEN SALES AND SERVICE INC
Address:2043 S 35TH ST
Box:11393
City:TACOMA
State:WA
ZIP:98411-0393
Country:US
CAGE:5H199
============= Composition/Information on Ingredients =============
Name:HELIUM
(FORMULA HE MW:4.003)
CAS:7440-59-7
RTECS #:NH6520000
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PERSONNEL, INCLUDING RESCUE WORKERS,
SHOULD NOT ENTER AREAS WHERE THE OXYGEN CONCENTRATION IS BELOW
19%, UNLESS PROVIDED W/SELFCONTAINED BREATHING APPARATUS OR AIRLINE
RESPIRATOR.
Explanation of Carcinogenicity:HELIUM IS A SIMPLE ASPHYXIANT AND HAS NO
TLV
Effects of Overexposure:EXPOSURE TO OXYGEN DEFICIENT ATMOSPHERES MAY
PRODUCE DIZZINESS,NAUSEA,VOMITING, LOSS OF CONSCIOUSNESS, AND
DEATH. EXTENSIVE TISSUE DAMAGE OR BURNS CAN RESULT FROM EXPOSURE
TO LIQUID HELIUM OR COLD H ELIUM VAPORS.
======================= First Aid Measures =======================
First Aid:PERSONS SUFFERING FROM LACK OF OXYGEN SHOULD BE MOVED TO
AREAS WITH NORMAL ATMOSPHERES. ASSISTED RESPIRATION & SUPPLEMENTAL
OXYGEN SHOULD BE GIVEN IF VICTIM IS NOT BREATHING. IF CRYOGENIC
LIQUID OR CO LD BOIL OFF GAS CONTACTS WORKER'S SKINOR EYES, FROZEN
TISSUES SHOULD BE FLOODED/SOAKED W/TEPID WATER(105-115F;41-46C) DO
NOT USE HOT WATER!! SHOULD SEEK MEDICAL ATTENTION IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NA
Fire Fighting Procedures:NA
Unusual Fire/Explosion Hazard:NA
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID CONTACT OF SKIN W/LIQUID HELIUM OR ITS
COLD BOIL OFF GAS. FLUSH LIQ SPILL W/WTR TO DISPERSE. VENTILATE
ENCLOSED AREAS TO PREVENT FORMATION OF OXYGEN DEFICIENT
ATMOSPHERES CAUSED BY EVAPORATION OF LIQUID HELIUM OR THE RELEASE
OF GASEOUS HELIUM.
====================== Handling and Storage ======================
Handling and Storage Precautions:PREVENT CONTACT OF LIQ HELIUM/COLD
BOILOFF GAS W/ SKIN.USE A SUITABLE HANDTRUCK.STORE LIQ CONTNR &
CYLINDER IN WELL VENTL AREA.KEEP FROM SOURCES HEAT
Other Precautions:STORAGE SHOULD NOT BE A HEAVY TRAFFICKED AREA.
SEGREGATE FULL & EMPTY CYLINDERS.AVOID EXPOSURE TO AREAS WHERE SALT
OR CORROSIVE CHEMICAL ARE PRESENT. STORAGE SHOULD BE FREE OF
COMBUSTIBLE MATERIAL.A VOID ROLLING,DRAGGING,OR SLIDING CYLNDR.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SELFCONTAINED BREATHING APPARATUS IN OXYGEN
DEFICIENT ATMOSPHERES. CAUTION!! RESPIRATORS WILL NOT FUNCTION.
USE MAY RESULT IN ASPHYXIATION.
Ventilation:NATURAL OR MECHANICAL WHERE GAS IS PRESENT. VENTS SHOULD BE
SITUATED TO AVOID HIGHER THAN NORML CONCENTRATION OF HELIUM
Protective Gloves:LOOSE FITTING OF IMPERMEABLE AS LEATHER
Eye Protection:SAFETY GLASSES/CHEMICAL GOGGLES
Other Protective Equipment:NONE
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-452.1F
Vapor Pres:NA
Vapor Density:0.01114
Spec Gravity:1 ATM 0.138
Solubility in Water:1ATM0.861% BY VOLUME
Appearance and Odor:HELIUM IS COLORLESS & ODORLESS IN BOTH GASEOUS &
LIQUID STATES
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE
==================== Disposal Considerations ====================
Waste Disposal Methods:ALLOW LIQUID HELIUM TO EVAPORATE IN A WELL
VENTILATED LOCATION REMOTE FROM WORK AREAS. DO NOTATTEMPT TO
DISPOSE RESIDUAL HELIUM IN COMPRESSED GAS CYLINDERS. VENT HELIUM
GAS SLOWLY TO A WELL VENTL OUTDOORS LOCATION REMOTE FROM WORK
AREAS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|