===================== Product Identification =====================
MSDS NAME:EA 9313 EPOXY RESIN, PART B
NIIN:01-107-4000
Kit Part:Y
MSDS Number: BHGFK
=== Responsible Party ===
Company:DEXTER ADHESIVES AND STRUCTURAL MATERIALS DIVISION
Address:2850 WILLOW PASS ROAD
Box:312
City:PITTSBURG
State:CA
ZIP:94565-3237
Country:US
Info Phone Num:415-687-4201
Emergency Phone Num:415-687-4201
Preparer's Name:SUZANNE FRANZ
CAGE:33564
=== Contractor Identification ===
Company:DEXTER CORPORATION ADHESIVE & COATING SYSTEMS
Address:2850 WILLOW PASS ROAD
Box:312
City:BAY POINT
State:CA
ZIP:94565-3299
Country:US
Phone:202-483-7616
CAGE:33564
============= Composition/Information on Ingredients =============
Name:EPOXY RESIN SYSTEM
Fraction by Wt: 100%?
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS CORROSIVE TO BODY TISSUES
CAUSING BURNS ON CONTACT OR VERY SOON THEREAFTER. VAPORS ARE
SEVERELY IRRITATING AND MAY SENSITIZE ALLERGIC REACTIONS
Explanation of Carcinogenicity:MFR CLAIMS THAT NONE OF THE COMPOUNDS IN
THIS PRODUCT IS LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYE:SEVERE IRRITATION, BURNS.
SKIN:IRRITATION, BURNS, MAY SENSITIZE ALLERGIC REACTIONS.
INHALED:RESPIRATORY IRRITATION. INGESTED:SEVERE G/I IRRITATION,
BURNS TO THE MUCOUS MEMBRANES.
Medical Cond Aggravated by Exposure:ANY RESPIRATORY OR SKIN CONDITION,
ESPECIALLY IN CASES OF SENSITIZATION
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/WATER 15 MIN HOLD LIDS OPEN. SEE DOCTOR.
SKIN:REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. WASH
WITH SOAP & WATER, ALCOHOL, OR HAND CLEANER.(DO NOT USE SOLVENTS.)
INHALATION:PR ODUCT IS NOT VOLATILE AND THUS NO PROBLEM AT NORMAL
TEMPERATURE. INGESTED:UNLIKELY, BUT IF OCCURS, DO NOT INDUCE
VOMITING, GET IMMEDIATE MEDICAL CARE. IF IRRITATION PERSISTS,OR IS
SEVERE,SEE A DOCTOR.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:261F,127C
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF DENSE SMOKE OR TOXIC GASSES.
================== Accidental Release Measures ==================
Spill Release Procedures:WIPE UP OR ABSORB ON SUITABLE MATERIAL AND
SHOVEL UP. AVOID ALL PERSONAL CONTACT. CLEAN AREA WITH SOLVENTS
OBSERVING ANY PRECAUTIONS DUE TO FLAMMABILITY
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS AND OPEN
FLAMES. KEEP CONTAINER CLOSED WHEN NOT IN USE. STORE AT ROOM
TEMPERATURE 12 MONTHS.
Other Precautions:FOLLOW RECOMMENDED CURING SCHEDULE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NORMALLY REQUIRED. USE PROPERLY FITTED
RESPIRATOR (NIOSH/MSHA APPROVED FOR ORGANIC VAPORS/MISTS) DURING
AND AFTER APPLICATION UNLESS AIR MONITORING VAPOR/MIST LEVELS ARE
BELOW PEL/TLV.
Ventilation:MFR RECOMMENDS USE OF LOCAL EXHAUST TO KEEP EXPOSURES BELOW
PEL/TLV.
Protective Gloves:BUTYL, PVA OR VITON RUBBER GLOVES
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES
Other Protective Equipment:AS NEEDED TO AVOID PROLONGED AND/OR REPEATED
CONTACT.
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID ANY
UNNECESSARY CONTACT.
Supplemental Safety and Health
THIS IS PART B OF A TWO PART PRODUCT.
================== Physical/Chemical Properties ==================
HCC:B2
Vapor Density:8.45
Spec Gravity:1.02
Evaporation Rate & Reference:NIL
Solubility in Water:NIL
Appearance and Odor:REDDISH ORANGE LIQUID WITH AN AMMONIACAL ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
NITROGEN OXIDES, ALDEHYDES, ACIDS AND UNIDENTIFIED ORGANIC
COMPOUNDS.
Conditions to Avoid Polymerization:AVOID MIXING BATCHES LARGER THAN 1
POUND. DO NOT HEAT MIXED ADHESIVE UNLESS IN THIN SECTIONS AS WITH
BONDING SURFACES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.DO
NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|