Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: diampestcontrol_com---termidorsc_l0402.asp
DIRECTIONS FOR USE: CARPENTER ANTS AND NUISANCE ANT CONTROL (Argentine ants, big-headed ants, Odorous House ants and Pave-
ment ants): For control of ants around houses and other sturctures, apply 0.06% Termidor SC Termiticide/Insecticide to the structure exterior
as a low pressure coarse spray where ants enter the structure, trail around the structure or where they crawl and hide. Also spray 0.06% Termi-
dor SC Termiticide/Insecticide around doors, windows, vents, pipes or any other exterior openings (including foundation cracks or drilled holes)
where ants could enter the structure. Be especially careful to treat the joint where exterior siding (wood, vinyl, aluminum or any similar mate-
rial) meets the cement, block or brick foundation. Treat all areas where any wires (electrical, telephone or cable) enter the house. This treat-
ment should be made as a general surface spray, crack and crevice spray or wall void application. Apply 2 quarts of 0.06% Termidor SC Termiticide/
Insecticide finished spray per 160 linear feet. (This rate is approximately 1.5 gallons finished spray per 1000 square feet). Application is made
one foot out and one foot up the foundation wall with a maximum number of 2 applications per year.
It is also necessary to remove or prune away all shrubbery, bushes, tree branches (dead or alive) touching the structure. This vegetation touch-
ing the structure offers a route of entry for ants into the structure and a method for the ants to continue to inhabit the structure without
coming in contact with the treatment. If nests are found, direct treatment of Termidor SC Termiticide/Insecticide can be made to these nests.
Do not allow residents and pets in the immediate area during application and do not contact treated areas until sprays have dried.



LIMITED WARRANTY AND DISCLAIMER
The manufacturer warrants (a) that this product conforms to the chemical description on the label; (b) that this prod-
uct is reasonably fit for the purposes set forth in the directions for use when it is used in accordance with such direc-
tions; and (c) that the directions, warnings, and other statements on this label are based upon responsible experts�
evaluation of reasonable tests of effectiveness, of toxicity to laboratory animals and to plants, and residues on food
crops, and upon reports of field experience. Tests have not been made on all varieties or in all states or under all
conditions. THE MANUFACTURER NEITHER MAKES NOR INTENDS, NOR DOES IT AUTHORIZE ANY AGENT OR REPRESEN-
TATIVE TO MAKE, ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND IT EXPRESSLY EXCLUDES AND DISCLAIMS ALL
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
THIS WARRANTY DOES NOT EXTEND TO, AND THE BUYER SHALL BE SOLELY RESPONSIBLE FOR, ANY AND ALL LOSS OR
DAMAGE WHICH RESULTS FROM THE USE OF THIS PRODUCT IN ANY MANNER WHICH IS INCONSISTENT WITH THE LABEL
DIRECTIONS, WARNINGS, OR CAUTIONS.
BUYER’S EXCLUSIVE REMEDY AND MANUFACTURER’S OR SELLER’S EXCLUSIVE LIABILITY FOR ANY AND ALL CLAIMS, LOSSES,
DAMAGES, OR INJURIES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT, WHETHER OR NOT BASED IN CON-
TRACT, NEGLIGENCE, STRICT LIABILITY IN TORT OR OTHERWISE, SHALL BE LIMITED, AT THE MANUFACTURER’S OPTION,
TO REPLACEMENT OF, OR THE REPAYMENT OF THE PURCHASE PRICE FOR, THE QUANTITY OF PRODUCT WITH RESPECT
TO WHICH DAMAGES ARE CLAIMED. IN NO EVENT SHALL MANUFACTURER OR SELLER BE LIABLE FOR SPECIAL, INDIRECT
OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT WHEN USE OR HANDLING
IS NOT IN ACCORDANCE WITH LABEL DIRECTIONS.
NOTICE TO BUYER
Purchase of this material does not confer any rights under patents governing this product or the use thereof in coun-
tries outside the United States.


LABEL LICENSE FOR TERMIDOR
Termidor is specially formulated and sold by Aventis Environmental Science USA LP for the control of termites accord-
ing to the directions on this label. Aventis is the owner of United States patent rights to the active ingredient, fipronil,
formulations containing the active ingredient and methods of use, particularly U.S. Patent Nos. 5,232,940; 5,614,182;
and 5,700,460. The purchase price of Termidor includes a royalty whereby the purchaser acquires a prepaid license
under which purchaser agrees to employ the purchased quantity of Termidor only for the above-specified uses under
Aventis� United States patent rights and to provide notice of the terms and conditions of this license to any subse-
quent purchaser. Uses of Termidor other than those specified on this label are not licensed through the purchase of
this product and the use of this product for other purposes may violate this license and patent rights of Aventis.



Termidor is a registered trademark of the Aventis Group.
Fipronil is protected by U.S. Patent No. 5,232,940.




TERM-SL-20M--4/02

7
TERMIDOR® SC Termiticide/Insecticide as liquid to assure proper treat-
3. When appropriate (e.g., on the water side of the structure), the
treated backfill technique (described above) can also be used to ment volume and concentration in the treated area.
minimize off-site movement of TERMIDOR® SC. MIXING TABLE FOR TERMIDOR® SC TERMITICIDE/INSECTICIDE FOAM
PLENUM CONSTRUCTION TERMIDOR® SC Gallons of Foam Finished
BEFORE TREATMENT: Turn off the air circulation system of the struc- Use Dilution Finished Expansion Foam
ture until application has been completed and all TERMIDOR® SC Ter- Solution Ratio* (gallons)
miticide/Insecticide has been absorbed by the soil. 1 25:1
Application of TERMIDOR® SC Termiticide/Insecticide to the exterior 0.06% a.i. 2.5 10:1 25
perimeter of foundation walls should follow the instructions listed 5 5:1
above in “Accessible Crawl Space Construction�, including instructions
1 25:1
for sloping (tiered) soils.
0.125% a.i. 2.5 10:1 25
Interior treatment of plenum structures that use a sealed underfloor
5 5:1
space to circulate heat and/or cooled air throughout the structure need
* Add the manufacturer’s recommended quantity of foam agent to
to follow the instructions below:
the TERMIDOR® SC Termiticide/Insecticide solution.
1. Remove the sealing fabric and anything on the sealingfabric to
POSTS, POLES, WOOD LANDSCAPE ORNAMENTATION
expose no more than 18 inches adjacent to all foundation struc-
Do not contaminate wells or cisterns.
tures, including foundation walls, interior piers, pipes, and any
other structures with soil contact. Follow the instructions listed Preventative Treatment: Create a continuous chemical barrier in the
above for exterior and interior treatment of “Accessible Crawl Space soil around wooden posts, poles, fence posts, signs or landscape or-
Construction�. namentation. Apply a 0.06% or 0.125% solution of TERMIDOR® SC Ter-
2. After the finished solution of TERMIDOR® SC Termiticide/Insecti- miticide/Insecticide at the rate of 4 gallons per 10 linear feet per foot
cide has beenabsorbed by the soil, replace the sealing fabric and of depth. For treatments made during installation, the finished solu-
anything to be placed on the sealing fabric to its original, pre- tion may be applied to soil as it is replaced around the post or pole.
treatment position. The finished application should place termiticide to a depth of six inch-
es below the bottom of the posts, poles, or other wooden items in
FOAM APPLICATIONS
contact with the soil.
Construction practices, soil subsidence, and other factors may create
situations where a continuous chemical barrier cannot be achieved Curative Treatment: Previously installed poles, posts, landscape or-
using conventional liquid treatment alone. In such situations, con- namentation, or signs may be treated with a 0.06% or 0.125% finished
ventional liquid application methods can be supplemented through solution of TERMIDOR® SC Termiticide/Insecticide by sub-surface in-
the use of foam generating equipment. Treatment of filled stoops and jection or treated by gravity flow through holes made from the bot-
porches, chimney bases, piers, soil under concrete slabs, into block tom of a trench around the pole or post. When trenching, the trench
voids, behind masonry, other veneers, and stud walls are examples need not be wider than 6 inches wide and 6 inches deep. When sub-
where foam applications may be useful. Foam applications to wall surface injecting, treat all sides to create a continuous barrier. Apply
voids in stud walls must utilize dry foam only (25:1 to 50:1 expansion to a depth of six inches below the bottom of the wood.
ratio). Only apply foam to wall voids where termites or termite dam- Termites Above Ground: For control of termites, aerial colonies, or
age are present. drywood termites in localized areas of infested wood structures, ap-
In general, “foam only� treatment is appropriate when attempting to ply at a 0.06% or 0.125% solution of Termidor SC Termiticide/Insecti-
maximize horizontal coverage in areas where there is no deep foun- cide to infested areas of wooden members/voids. Application may be
dation or footing [e.g. around plumbing entries, settling under slabs, made to inaccessible areas by drilling, and then injecting the finished
and near cracks in concrete]. In areas where both lateral spread and solution with a crack and crevice injector into the damaged wood or
deeper vertical penetration of the termiticide is needed both foam void spaces.
and conventional liquid should be used [e.g. adjacent to foundation Termite carton nests in trees or building voids may be injected with
walls]. Foam and liquid applications must be consistent with volume 0.06% or 0.125% solution using pointed injection tool. Multiple injec-
and active ingredient instructions in order to ensure proper applica- tion points to varying depths may be necessary. It is desirable to physi-
tion has been made. The volume and amount of active ingredient cally remove carton nest material from building voids when such nests
are essential to an effective treatment. At least 75% of the gallons of are found.
the 0.06% or 0.125% TERMIDOR® SC Termiticide/Insecticide finished so-
DO NOT TREAT FRUIT OR NUT-BEARING TREES.
lution must be applied as a typical liquid treatment. The remaining
25% or less gallons is delivered to appropriate locations using a foam RETREATMENT INSTRUCTIONS
application. The total amount of product applied with the combina- Retreatment for subterranean termites can only be performed if there
tion of foam and liquid finished solution should be equivalent to that is clear evidence of reinfestation or disruption of the barrier due to
of an application of liquid finished solution only. Foam applications construction, excavation, or landscaping and/or evidence of the break-
are generally a good supplement to liquid treatments in difficult ar- down of the termiticide barrier in the soil. These vulnerable or rein-
eas, but may be used in difficult to access spot treatments. fested areas may be retreated in accordance with application
techniques described on this label. The timing and type of these re-
Foam Mixing Instructions and Application
treatments will vary depending on factors such as termite pressure,
Prepare the finished solution of TERMIDOR® SC Termiticide/Insecticide
soil types, soil conditions and other factors which may reduce the ef-
and mix it with manufacturer’s recommended volume of foaming
fectiveness of the barrier. Annual re-treatment of the structure is pro-
agent in approved foaming equipment. Apply a sufficient volume of
hibited unless there is clear evidence that reinfestation, barrier
TERMIDOR® SC foam formulation to provide a continuous barrier at
disruption and/or evidence of breakdown has occurred.
the recommended rate for specific applications [these various rates
TERMIDOR SC Termiticide/Insecticide can be used to control ants,
are provided in the text of this label]. If sufficient foam volume can-
Carpenter ants and nuisance ants (including Argentine ants, Big-
not be applied to achieve the recommended rate of TERMIDOR® SC
Headed ants, Odorous house ants and Pavement Ants).
Termiticide/Insecticide required, apply additional finished solution of
6
structure be treated below the footing. application wand, use one or more extension rods to make the
application to the soil. Do not broadcast or power spray with high
INSIDE PERIMETER
pressures.
To treat under the basement floor slab, drill vertically through the slab
2. To establish a horizontal barrier, drill through the foundation
along the interior perimeter of the foundation. Drill holes along all
wall or through the floor above and treat the soil perimeter at a
concrete expansion joints, cracks, plumbing, and utility services pen-
rate of 1 gallon of 0.06% or 0.125% TERMIDOR® SC Termiticide/
etrating the slab. Drill holes along both sides of partition foundation
Insecticide per 10 square feet. Drill spacing must be at intervals
walls, and around piers. It may be necessary to drill holes along one
not to exceed 16 inches. Many states have smaller intervals so check
side of the slab adjacent to a non-foundation interior partition wall if
state regulations which may apply.
there is clear evidence of termite activity in the wall. All drill holes
through the slab should be spaced so as to achieve a continuous chem- Hollow Block Foundations/Voids
ical barrier but in no case be more than 12 inches apart. Inject a 0.06% Drill and treat voids in multiple masonry elements of the structure
or 0.125% solution of TERMIDOR® SC Termiticide/Insecticide into the extending from the structure to the soil in order to create a continu-
drilled holes at the rate of 4 gallons per 10 linear feet per foot of depth. ous treatment barrier in the area to be treated. Apply at the rate of 2
For best results, application should be made with a lateral dispersal gallons of finished solution per 10 linear feet of footing using a noz-
nozzle. All holes in commonly occupied areas into which material has zle pressure of 25 p.s.i. or less. When using this treatment, access holes
been applied must be plugged. Plugs must be of a non-cellulose ma- must be drilled below the sill plate and should be as close as possible
terial or covered by an impervious, non-cellulose material. to the footing as is practical. Treatment of voids in block or rubble
foundation walls must be closely examined: Applicators must inspect
ACCESSIBLE CRAWL SPACE CONSTRUCTION
areas of possible runoff as a precaution against application leakage
BEFORE TREATMENT: Turn off the air circulation system of the struc-
in the treated areas. Some areas may not be treatable or may require
ture until application has been completed and all TERMIDOR® SC Ter-
mechanical alteration prior to treatment.
miticide/Insecticide has been absorbed by the soil.
All leaks resulting in the deposition of TERMIDOR® SC Termiticide/In-
For crawl spaces, apply vertical termiticide barriers at the rate of 4
secticide in locations other than those prescribed on this label must
gallons of 0.06% or 0.125% TERMIDOR® SC Termiticide/Insecticide per
be cleaned up prior to leaving the application site. Do not allow peo-
10 linear feet per foot of depth from grade to the top of the footing,
ple or pets to contact contaminated areas or to reoccupy the contam-
or if the footing is more than 4 feet below grade, to a minimum depth
inated areas of the structure until the clean up is completed.
of 4 feet. Apply by trenching and rodding into the trench, or trench-
Not for use in voids insulated with rigid foam.
ing. Treat both sides of the foundation and around all piers and
pipes. Where physical obstructions, such as concrete walkways adja- TREATMENT OF STRUCTURES WITH WELLS OR CISTERNS
cent to foundation elements, prevent trenching, treatment may be Do not contaminate wells or cisterns
made by rodding alone. When soil type and/or conditions make
Do not apply TERMIDOR® SC Termiticide/Insecticide within 5 feet of
trenching prohibitive, rodding may be used. When the top of the foot-
any well or cistern by rodding and/or trenching or by the backfill meth-
ing is exposed, the applicator must treat the soil adjacent to the foot-
od. Treat soil between 5 and 10 feet from the well or cistern by the
ing to a depth not to exceed the bottom of the footing. Read and follow
backfill method only. Treatment of soil adjacent to water pipes with-
mixing and use directions on this label if situations are encountered
in 3 feet of grade should only be done by the backfill method.
where the soil will not accept the full application volume.
1. Trench and remove soil to be treated onto heavy plastic
* Rod holes and trenches must not extend below the
sheeting or similar material or into a wheelbarrow.
bottom of the footing.
2. Treat soil at the rate of 4 gallons of 0.06% or 0.125% TERMIDOR®
* Rod holes must be spaced so as to achieve a continu-
SC Termiticide/Insecticide per 10 linear feet per foot of depth of
ous chemical barrier but in no case more than 12 the trench, or 1 gallon of 0.06% or 0.125% TERMIDOR® SC Termiti-
inches apart. cide/Insecticide per 1.0 cubic foot of soil. Mix thoroughly into the
* Trenches must be a minimum of 6 inches deep or to the soil taking care to contain the liquid and prevent runoff or
bottom of the footing, whichever is less, and need not e spillage.
wider than 6 inches. When trenching in sloping (tiered) soil, 3. After the treated soil has absorbed the TERMIDOR® SC Termiticide/
the trench must be stepped to ensure adequate distribution Insecticide finished solution, return the soil into the trench.
and to prevent termiticide from running off. The 0.06% or
Structures with Adjacent Wells/Cisterns and/or Other Water
0.125% TERMIDOR® SC Termiticide/Insecticide solution must be
Bodies
mixed with the soil as it is replaced in the trench.
Applicators must inspect all structures with nearby water sources such
INACCESSIBLE CRAWL SPACE CONSTRUCTION
as wells, cisterns, surface ponds, streams, and other bodies of water
BEFORE TREATMENT: Turn off the air circulation system of the struc-
and evaluate, at a minimum, the treatment recommendations listed
ture until application has been completed and all TERMIDOR® SC Ter-
below prior to making an application.
miticide/Insecticide has been absorbed by the soil
1. Prior to treatment, if feasible, expose the water pipe(s) coming from
For inaccessible interior areas, such as areas where there is insuffi- the well to the structure, if the pipe(s) enter the structure within
cient clearance between floor joists and ground surfaces to allow op- 3 feet of grade. Treatment of soil adjacent to the water pipe(s)
erator access, excavate, if possible, and treat according to the should be done according to the backfill technique described
instructions for accessible crawl spaces. Otherwise, apply one, or a above.
combination of the following two methods.
2. Prior to treatment applicators are advised to take precautions to
1. To establish a horizontal barrier, apply to the soil surface, 1 limit the risk of applying the termiticide into subsurface drains that
gallon of 0.06% or 0.125% TERMIDOR® SC Termiticide/Insecticide could empty into any bodies of water. These precautions include
per 10 square feet overall using a nozzle pressure of less than 25 evaluating whether application of TERMIDOR® SC Termiticide/
p.s.i and a coarse application nozzle (e.g., Delvan Type RD Rain Insecticide to the top of the footer may result in contamination of
drop, RD-7 or larger, or Spraying Systems Co. 80110LP Teejet or the subsurface and degree of compaction should be taken into
comparable nozzle). For an area that cannot be reached with the account in determining the depth of treatment.
5
CONCRETE SLAB OVER SOIL [INCLUDING MONOLITHIC, FLOATING inspection vent should be cut and installed, if not already present.
AND SUPPORTED CONCRETE SLABS] After inspection and removal of all wood/cellulose debris, the soil
can be treated by rodding or drenching the soil with a 0.06% or
EXTERIOR PERIMETER
0.125% solution of TERMIDOR® SC Termiticide/Insecticide.
Apply by trenching and rodding into the trench or trenching
around the foundation at the rate of 4 gallons finished solution Structures with French Drains and Sump Pumps
(0.06% or 0.125% TERMIDOR® SC Termiticide/Insecticide) per 10 lin- French drains eliminate water at the footer along a foundation
ear feet per foot of depth, or if the footing is more than 4 feet be- perimeter. They are common in hollow block foundation struc-
low grade, to a depth of 4 feet. Trenches must be a minimum of tures to drain water seeping from the exterior perimeter or un-
6 inches deep or to the bottom of the footing and need not be derneath the foundation. Soil must be dry before applying to sites
wider than 6 inches. The finished solution (0.06% or 0.125% TER- with French drains. Do not treat soil that is saturated or frozen.
MIDOR® SC Termiticide/Insecticide) should be mixed with the soil Do not apply when precipitation is likely to occur. Do not rod thru
as it is replaced in the trench. Rod holes must be spaced so as to the slab any closer than 24 inches to the french Drain to prevent
achieve a continuous chemical barrier but in no case more than finished solution seepage and/or damage to the drain or the tiles.
12 inches. However, in no case should the structure be treated Do not apply inspection vent should be cut and installed, if not
below the footing. already present. After inspection and removal of all wood/cellu-
lose debris, the soil can be treated by rodding or drenching the
SUB-SLAB INJECTION
soil with a 0.06% or 0.125% solution of TERMIDOR® SC Termiti-
Sub-slab injection treatments can be made from inside the struc-
cide/Insecticide within 5 feet of the sump pit and pump. Do not
ture or in cases where by drilling through the foundation from the
drill through hollow block foundations that border the French
outside as directed below. Prior to making any treatments, locate
Drain in order to prevent drainage/seepage from the block into
all heating/air conditioning ducts, vents, water/sewer lines, and
the drain.
electrical lines/conduits.
Once French drains have been identified and located, apply TER-
Vertical Drilling/Injection: To treat under the slab, drill vertically
MIDOR® SC Termiticide/Insecticide as follows: 1) unplug the sump
through the slab along the interior perimeter of the foundation
pump. Inspect sump pit for water. If no water is present, the treat-
including the garage. Drill holes along all concrete expansion
ment can be made provided the sump pump remains un-
joints, cracks, plumbing, and utility services penetrating the slab.
plugged.; or 2) if water is in the sump pit, unplug the sump pump
It may be necessary to drill holes along one side of the slab adja-
and remove four cups of water from the pit. Mark the water lev-
cent to an interior partition wall if there is clear evidence of ter-
el. Wait 10 minutes and check the water level in the pit again. If
mite activity or damage in the wall. All drill holes through the slab
the water level has risen, there is too much seepage to perform
should be spaced so as to achieve a continuous chemical barrier
the treatment at this time. If the water level does not rise, make
but in no case be more than 12 inches apart. Inject a 0.06% or
the treatment provide the sump pump remains unplugged.
0.125% solution of TERMIDOR® SC Termiticide/Insecticide into the
drilled holes at the rate of 4 gallons per 10 linear feet per foot of During application, check the sump pump pit every few minutes
depth. For best results, application should be made with a lateral for the presence of termiticide solution. If solution is detected,
dispersal nozzle. All holes in commonly occupied areas into which stop treatment immediately and remove solution from the pump
material has been applied must be plugged. Plugs must be of a pit. All solution must be removed from the sump pump pit be-
non-cellulose material or covered by an impervious, non-cellulose fore plugging in the sump pump again. Dispose of solution from
material. the sump pump as directed by this label in the “Pesticides Dis-
Horizontal Drilling/Rodding/Sub-slab Injection from the Exterior posal� section.
of the Foundation: This technique should be used to treat under- BASEMENT STRUCTURES
neath the slab only when floors or interior design do not allow for
EXTERIOR PERIMETER
vertical drilling. Care must be exercised not to rod into heating
Apply by trenching and rodding into the trench or trenching
ducts, water/sewer lines, and electrical lines/conduits. Horizon-
around the foundation at the rate of 4 gallons finished solution
tal short-rodding practices can be used to establish a continuous
(0.06% or 0.125% inspection vent should be cut and installed, if
chemical barrier along the inside perimeter of the foundation.
not already present. After inspection and removal of all wood/
Holes should be drilled from outside the foundation at an angle
cellulose debris, the soil can be treated by rodding or drenching
which allows a finished solution (0.06% or 0.125%) of TERMIDOR®
the soil with a 0.06% or 0.125% solution of TERMIDOR® SC Ter-
SC Termiticide/Insecticide to be deposited below heating ducts, wa-
miticide/Insecticide) per 10 linear feet per foot of depth, or if the
ter/sewer lines, and electrical conduits if present. Horizontal long
footing is more than 4 feet below grade, to a depth of 4 feet.
rodding practices may only be employed to treat areas underneath
Trenches must be a minimum of 6 inches deep or to the bottom
the slab that are not accessible by vertical rodding or horizontal
of the footing and need not be wider than 6 inches. When trench-
short rodding. Long rods exceeding 20 feet should not be used.
ing in sloping tiered soil, the trench must be stepped to ensure
For all horizontal rodding applications, all drill holes through the
adequate distribution and to prevent inspection vent should be
foundation should be spaced so as to achieve a continuous chem-
cut and installed, if not already present. After inspection and re-
ical barrier but in no case be more than 12 inches apart. Inject a
moval of all wood/cellulose debris, the soil can be treated by rod-
0.06% or 0.125% solution of TERMIDOR® SC Termiticide/Insecticide
ding or drenching the soil with a 0.06% or 0.125% solution of
into the drilled holes at the rate of 4 gallons per 10 linear feet per
TERMIDOR® SC Termiticide/Insecticide from running out of the
foot of depth. For best results, make applications with a lateral
trench. The finished solution (0.06% or 0.125% inspection vent
dispersal nozzle. All holes must be plugged. Plugs must be of a
should be cut and installed, if not already present. After inspec-
non-cellulose material or covered by an impervious, non-cellulose
tion and removal of all wood/cellulose debris, the soil can be
material.
treated by rodding or drenching the soil with a 0.06% or 0.125%
BATH TRAPS: Exposed soil or soil covered with tar or similar seal- solution of TERMIDOR® SC Termiticide/Insecticide) should be
ant beneath or around plumbing and/or drain pipe entry areas mixed with the soil as it is replaced in the trench. Rod holes must
should be treated with a minimum of 1 gallon but no more than be spaced so as to achieve a continuous chemical barrier but in
4 gallons of finished solution* per square foot. An access door or no case more than 12 inches. However, in no case should the
4
to check for leaks. All leaks resulting in the deposition of termiti- To Mix 0.06% Desire Finished Start With Add [ounces of
Solution of TERMIDOR® SC TERMIDOR® SC
cide in locations other than those prescribed on this label must be [gallons of water]
cleaned up prior to leaving the application site. Do not allow peo- Termiticide/Insecticide Termiticide/Insecticide]
ple or pets to contact contaminated areas or to reoccupy contam- 100 gallons finished solution 99.25 78 oz. [or 2 qt. + 14 oz.]
inated areas of the structure until the clean up is completed. 50 gallons finished solution 49.75 39 oz. [or 1 qt. + 7 oz.]
* Do not apply TERMIDOR® SC Termiticide/Insecticide in a way that 25 gallons finished solution 24.75 19 oz. [or 1 pt. + 3 oz.]
will contact any other person. Only protected applicators wearing
1 gallon of finished solution 1 0.8 oz
personal protective equipment as required by this product label may
To Mix 0.125% Desired Finished Start With Add [ounces of
be in the area during application.
Solution of TERMIDOR® SC [gallons of TERMIDOR® SC
* All holes in commonly occupied areas into which TERMIDOR® SC
Termiticide/Insecticide water] Termiticide/Insecticide]
Termiticide/Insecticide has been applied must be plugged. Plugs
must be of a non-cellulose material or covered by an impervious, 100 gallons finished solution 98 gal. 156 oz. [or 1 gal. + 28 oz.]
non-cellulose material. 50 gallons finished solution 49.75 gal. 78 oz. [or 2 qt. + 14 oz.]
* Do not apply finished solution of TERMIDOR® SC Termiticide/
25 gallons finished solution 24.75 gal. 39 oz. [or 1 qt. + 7 oz.]
Insecticide until all heating/air conditioning ducts, air vents, plumb-
1 gallon of finished solution 1 gal. 1.6 oz.
ing pipes, sewer lines, floor drains, heating pipes and electrical lines/
conduits are known and identified. Do not puncture or contami- APPLICATION VOLUME
nate any of these. To provide maximum control and protection against termite infesta-
* Do not treat around any edible plants with TERMIDOR® SC tion, apply the volumes of TERMIDOR® SC Termiticide/Insecticide fin-
Termiticide/Insecticide used for termite control. ished solution specified in the “Directions For Use� throughout this
label. However, if the soil will not accept these labeled volumes of
* Do not contaminate public and private water supplies.
TERMIDOR® SC, twice the concentration of TERMIDOR® SC Termiticide/
* Do not treat while precipitation is occurring.
Insecticide may be applied in half the volume of finished solution.
* Do not treat soil that is water saturated or frozen.
For example, if 0.06% TERMIDOR® SC Termiticide/Insecticide cannot
* Use anti-backflow equipment on all filling hoses. be applied to achieve 4 gallons finished solution per 10 linear feet
* Do not use in tanks with borate contaminants. per foot of depth, then 0.125% TERMIDOR® SC Termiticide/Insecticide
applied in 2 gallons finished solution per 10 linear feet per foot of
GENERAL INFORMATION
depth may be substituted. These “application volume� instructions do
In order to maximize the termiticide potency of TERMIDOR® SC Ter-
not ever apply to ground that is water saturated or frozen. Do not treat
miticide/Insecticide, it should be applied in a manner to provide a con-
while precipitation is occuring. Do not treat soil that is water saturat-
tinuous chemical barrier to prevent termites from attacking the wood
ed or frozen or in any conditions where run-off or movement from
to be protected. TERMIDOR® SC Termiticide/Insecticide should only
the treatment area (site) is likely to occur.
be applied by licensed technicians familiar with trenching, rodding,
short rodding, subslab injection, low pressure banded surface appli- NOTE: Large reductions of application volume reduce the ability to
cations, and foam delivery techniques. TERMIDOR® SC Termiticide/ obtain a continuous barrier. Variance is allowed when volume and
Insecticide is highly effective against a variety of subterranean termites concentration are consistent with label directed rates and a continu-
including species of Reticulitermes, Zootermopsis, Heterotermes, and ous chemical barrier is still achieved. At reduced application volume;
Coptotermes. While TERMIDOR® SC is labeled for use at 0.06% - 0.125% it may be necessary for the applicator to drill holes closer than 12 inch-
finished solution, the 0.06% finished solution should be used for typ- es apart to create a continuous barrier.
ical control situations. Where severe termite infestations occur, where
POST-CONSTRUCTION TREATMENT
problem soils occur or where difficult or problem construction types
General
are encountered, it may be necessary to use 0.125% TERMIDOR® SC
For applications made after the final grade is installed, the applicator
Termiticide/Insecticide.
must trench and rod into the trench or trench along the foundation
TERMIDOR® SC Termiticide/Insecticide is formulated as a water solu- walls and around pillars and other foundation elements, at either
ble concentrate liquid containing 9.1% active ingredient. 0.06% or 0.125% TERMIDOR® SC Termiticide/Insecticide from grade to
the top of the footing. When the footing is more than four (4) feet
MIXING INSTRUCTIONS
below grade, the applicator must trench and rod into the trench or
Mix TERMIDOR® SC Termiticide/Insecticide in the following manner:
trench along the foundation walls, at either 0.06% or 0.125% TERMI-
1. Fill tank 1/4 to 1/3 full with water. Filling hose must be equipped DOR® SC Termiticide/Insecticide, to a minimum depth of four feet. The
with an anti-backflow device. actual depth of treatment will vary depending on soil type, degree of
2. Start pump to begin by-pass agitation and place end of treating compaction, and location of termite activity. When the top of the foot-
tool in tank to allow circulation through hose. ing is exposed, the applicator must treat the soil adjacent to the foot-
3. Add appropriate amount of TERMIDOR® SC Termiticide/Insecticide. ing to a depth not to exceed the bottom of the footing. However, in
Refer to the table in the box below to determine the proper amount no case should a structure be treated below the footing.
to add to desired gallons of water. Do not apply finished solution (0.06% or 0.125% TERMIDOR® SC Ter-
4. Add remaining amount of water. miticide/Insecticide) until the location and type of (1) construction of
5. Let pump run and allow recirculation through the hose for 2 to 3 heat or air-conditioning ducts and vents, (2) water and sewer (or
minutes or longer, until TERMIDOR® SC Termiticide/Insecticide in plumbing) lines and (3) electrical lines/conduits are known and iden-
the tank has dissolved completely. tified. Caution must be taken to avoid contamination of and damage
to these structural elements and airways.




3
FIRST AID must be taken to avoid runoff. Do not contaminate water by cleaning
equipment or disposal of wastes. Do not contaminate water when dis-
IF SWALLOWED: If swallowed:
posing of equipment washwaters.
-Call a poison control center or doctor immediately for
treatment advice. DIRECTIONS FOR USE
-Have a person sip a glass of water if able to swallow.
It is a violation of Federal Law to use this product in a manner inconsis-
-Do not induce vomiting unless told to by a poison control tent with its labeling.
center or doctor.
Read entire label before using this product.
-Do not give anything by mouth to unconscious person.
For use by individuals/firms licensed or registered by the state to apply
IF ON SKIN If on skin or clothing:
termiticide products. States may have more restrictive requirements
OR CLOTHING: -Take off contaminated clothing.
regarding qualifications of persons using this product. Consult the struc-
-Rinse skin immediately with plenty of water for 15-20
tural pest control regulatory agency of your state prior to use of this prod-
minutes.
uct.
-Call a poison control center or doctor for treatment advice.
IF INHALED: If inhaled:
TERMIDOR® SC TERMITICIDE/INSECTICIDE
-Move person to fresh air.
FIND IT FAST GUIDE
-If person is not breathing, call 911 or ambulance, then give
Topic Page
artificial respiration, preferably mouth to mouth if possible.
Application Volume 3
-Call a poison control center or doctor for treatment advice.
Post Construction Bath Traps 4
IF IN EYES: If in eyes:
Emergency Phone Numbers Cover
-Hold eye open and rinse slowly and gently with water for 15-
Post Construction Concrete Slab 4
20 minutes. Remove contact lenses, if present, after the first
Emergency Treatment Cover
5 minutes, then continue rinsing eye.
Post Construction General 3
-Call a poison control center or doctor for treatment advice.
Foam Applications 6
Have the product container or label with you when calling a poison con-
Post Construction Inaccessible Crawl Space 5
trol center or doctor, or going for treatment.
General Information 3
NOTE TO PHYSICIAN: There is no specific antidote. All treatment should
Post Construction Hollow Block 5
be based on observed signs and symptoms of distress in the patient.
Limited Warranty and Disclaimer 7
Overexposure to materials other than this product may have occurred.
Post, Poles and Wood Landscape Ornamentation 6
In severe cases of overexposure by oral ingestion, lethargy, muscle trem-
Mixing Directions 3
ors, and in extreme cases, possibly convulsions may occur.
Retreatment 6-7
Plenums 5
PRECAUTIONARY STATEMENTS Storage and Disposal 2
HAZARDS TO HUMANS AND DOMESTIC ANIMALS Post Construction Accessible Crawl Space 5
Structures with Wells and Cisterns 5
CAUTION
Post Construction Basement 4
Harmful if swallowed, absorbed through skin or inhaled. Causes eye
irritation. Do not get in eyes, on skin or on clothing. Do not breathe
spray mist. STORAGE AND DISPOSAL
Do not contaminate water, food, or feed by storage or disposal.
PERSONAL PROTECTIVE EQUIPMENT (PPE)
All pesticide handlers (mixers, loaders, and applicators) must wear long- STORAGE
sleeved shirt and long pants, socks, shoes, and chemical-resistant gloves. Store unused product in original container only, out of reach of children and
All pesticide handlers must wear a dust/mist filtering respirator (MSHA/ animals.
NIOSH approval number prefix TC-21C) when working in a non-ventilat-
PESTICIDE DISPOSAL
ed space, including but not limited to crawl-spaces and basements. All
Pesticide wastes are acutely hazardous. Improper disposal of excess pesti-
pesticide handlers must wear protective eyewear (goggles, a faceshield,
cide is a violation of Federal Law. If these wastes cannot be disposed of by
or safety glasses with front, brow, and temple protection) when work-
use according to label instructions, contact your State Pesticide or Environ-
ing in a non-ventilated space, including but not limited to crawl-spaces
mental Control Agency, or the Hazardous Waste representative at the near-
and basements or when applying termiticide by rodding or sub-slab in-
est EPA Regional Office for guidance.
jection.
In case of minor spills or leaks, soak up with sand, earth or other suitable
User Safety Recommendations
material and dispose of wastes and broken or empty containers in a landfill
Users should wash hands thoroughly with soap and water before eating, approved for pesticide use.
drinking, chewing gum, using tobacco or using the toilet.
CONTAINER DISPOSAL
Remove contaminated clothing. Then wash body thoroughly with soap and Triple rinse (or equivalent). Then offer for recycling or reconditioning, or
water and put on clean clothing. Wash clothing with detergent and puncture and dispose of in a sanitary landfill, or incineration, or, if allowed
hot water before reusing. by state or local authorities, by burning. If burned, stay out of smoke.
Remove PPE immediately after handling this product. Wash outside
GENERAL PRECAUTIONS
of gloves before removing. Wash PPE before reusing.
* When treating adjacent to an existing structure, the applicator must
ENVIRONMENTAL HAZARDS check the area to be treated, and immediate adjacent areas of the
structure, for visible and accessible cracks and holes to prevent any
This pesticide is toxic to birds, fish, and aquatic invertebrates. Do not
leaks or significant exposures to persons occupying the structure. Peo-
apply directly to water, or to areas where surface water is present or to
ple present or residing in the structure during application must be
intertidal areas below the mean high water mark. Runoff from treated
advised to remove their pets and themselves from the structure if they
areas may be hazardous to aquatic organisms in neighboring areas. Care
see any signs of leakage. After application, the applicator is required
2
TERMIDOR® SC
Specimen Label
TERMITICIDE/
INSECTICIDE
For use by individuals/firms licensed or registered
by the state to apply termiticide products.

ACTIVE INGREDIENTS:
Fipronil: 5-amino-1-(2,6-dichloro-4-(trifluoromethyl)
phenyl)-4-((1,R,S)-(trifluoromethyl)sulfinyl)
-1-H-pyrazole-3-carbonitrile ............................. 9.1%
INERT INGREDIENTS: ....................................... 90.9%

EPA Reg. No. 432-901 EPA Est. No.

KEEP OUT OF REACH OF CHILDREN
CAUTION
Si usted no entiende la etiqueta, busque a alguien para que se la
explique a usted en detalle. (If you do not understand the label, find
someone to explain it to you in detail.)

FOR PRODUCT USE INFORMATION CALL
1-877-TERMIDOR
www.termidoronline.com
FOR MEDICAL AND TRANSPORTATION EMERGENCIES ONLY
CALL 24 HOURS A DAY 1-888-875-9907




NET CONTENTS:


AVENTIS ENVIRONMENTAL SCIENCE USA LP
95 Chestnut Ridge Road � Montvale, NJ 07645

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
diampestcontrol_com---speckozbifen_l0104.asp N/A
diampestcontrol_com---speckozbifen_m1203.asp 82657-04-3 082657-04-3 57-55-6
diampestcontrol_com---talpirid_l0504.asp N/A
diampestcontrol_com---talpirid_m0404.asp 63333-35-7
diampestcontrol_com---talstargranuals_l0303.asp N/A
diampestcontrol_com---talstargranuals_m1105.asp 82657-04-3
diampestcontrol_com---termidorsc_l0402.asp N/A
diampestcontrol_com---vectorbio5_l0500.asp N/A
diampestcontrol_com---vectorbio5_m0901.asp N/A
diampestcontrol_com---waspfreeze_l0304.asp N/A
diampestcontrol_com---weatherblokm0604.asp 56073-10-0
diampestcontrol_com---weatherblok_l0106.asp N/A
diampestcontrol_com---zprodentbait_l1004.asp 1314-84-7
diampestcontrol_com---zprodentbait_m0705.asp 1314-84-7
dura-barms_com---copper-aluminum_alloys.asp 7440-50-8 7429-90-5 7439-89-6 7439-92-1 7440-02-0 7440-31-5 7440-66-6 7439-96-5 7440-21-3
dura-barms_com---copper_alloys.asp 7440-50-8 7440-36-0 7436-89-6 7439-92-1 7440-02-0 7440-31-5 7440-66-6 7440-69-9
eutechinst_com---2008_accessories.asp N/A
eutechinst_com---ecbu4bt.asp 877-24-7 8877-24-7
eutechinst_com---ecbu7bt.asp 7778-77-0 7558-79-4
eutechinst_com---eccon1288bt.asp N/A
eutechinst_com---ecdpcbt.asp N/A
eutechinst_com---ecdpdtotal.asp 7681-11-0 6283-63-2
eutechinst_com---ei-lab-cat2005-r2.asp N/A
eutechinst_com---msds-conductivity-5ms.asp N/A
eutechinst_com---msds_glycine_sachet.asp N/A
eutechinst_com---phenol_red.asp N/A
fc-4500_-_neutral_cleaner_msds_sheet.asp 9016-45-9
fiberfrax_com---fb-97-fire-barrier-msds-m0365.asp N/A
fiberfrax_com---fb-97-heat-shield-msds-m0366.asp N/A
fiberfrax_com---fiberfrax-440-papers-msds-m0060.asp 142844-00-6 21645-51-2 65997-17-3 10043-01-3 9003-35-4 100-97-0 108-95-2
fiberfrax_com---fiberfrax-ab-l-and-ab-x-adhesive-backed-products-msds-m0363.asp 1318-00-9 142844-00-6 8002-74-2
fiberfrax_com---fiberfrax-anchor-loc2-ceramic-fiber-modules-msds-m0176.asp 142844-00-6 9038-95-3
fiberfrax_com---fiberfrax-azs-products-msds-m0114.asp 142844-00-6
fiberfrax_com---fiberfrax-bonded-30-felt-msds-m0104.asp 142844-00-6 1302-93-8 10043-01-3 7631-86-9 100-97-0
fiberfrax_com---fiberfrax-cc-max-2-series-mat-msds-m0354.asp 1302-93-8 142844-00-6 65997-17-3 10043-01-3
fiberfrax_com---fiberfrax-cc-max-4-series-mat-msds-m0356.asp 142844-00-6
fiberfrax_com---fiberfrax-cc-max-6-series-mat-msds-m0374.asp 142844-00-6
fiberfrax_com---fiberfrax-cc-max-8-series-mat-msds-m0393.asp 142844-00-6 7831-86-9
fiberfrax_com---fiberfrax-ceramic-fiber-azs-products-msds-m0033.asp 142844-00-6
fiberfrax_com---fiberfrax-double-heat-treated-woven-textiles-144-msds-m0074.asp 142844-00-6
fiberfrax_com---fiberfrax-duraboard-3000s-msds-m0300.asp 142844-00-6 1302-93-8 7631-86-9 9005-25-8 409-21-2
fiberfrax_com---fiberfrax-duraboard-hd-msds-m0039.asp 142844-00-6 1332-58-7 7631-86-9 9005-25-8
fiberfrax_com---fiberfrax-duraboard-ld-msds-m0042.asp 142844-00-6 112926-00-8 9005-25-8
fiberfrax_com---fiberfrax-durapack-rope-packing-msds-m0088.asp 142844-00-6 65997-17-3
fiberfrax_com---fiberfrax-es-boards-msds-m0165.asp 142844-00-6 7631-86-9 9005-25-8 1332-58-7
fiberfrax_com---fiberfrax-fc-25-tamping-mix-msds-m0050.asp 7732-18-5 7631-86-9 107-21-1 142844-00-6
fiberfrax_com---fiberfrax-felts-msds-m0027.asp 142844-00-6 9005-25-8 9003-35-4 35297-54-2 100-97-0 108-95-2
fiberfrax_com---fiberfrax-felts.asp N/A
fiberfrax_com---fiberfrax-fibersil-cloth-msds-m0081.asp 142844-00-6 65997-17-3 9003-07-0
fiberfrax_com---fiberfrax-heat-treated-woven-textiles-144-msds-m0071.asp 142844-00-6 65997-17-3 9003-07-0 61788-77-0

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC