HACH CO -- BUFFER SOLUTION PHOSPHATE TYPE, 431
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BZRFP
MSDS NAME: BUFFER SOLUTION PHOSPHATE TYPE, 431
Responsible Party
Name: HACH CO
Box: 907
City: AMES IA 50010
Info Phone: 800-227-4224
Emergency Phone Number: 303-623-5716
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: HACH COMPANY
Address: 100 DAYTON RD.
Box: 907
City: AMES IA 50010
Phone: 800-227-4224
=======================================================
Ingredients
=======================================================
Cas: 7558-79-4
RTECS #: WC4500000
Name: SODIUM MONOHYDROGEN PHOSPHATE(2:1:1); (SODIUM PHOSPHATE, DIBASIC
(ANHYDROUS)) (CERCLA)
% Wt: <5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 7758-11-4
Name: POTASSIUM PHOSPHATE, DIBASIC (ANHYDROUS)
% Wt: <5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Name: OTHER COMPONENTS
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 7732-18-5
RTECS #: ZC0110000
Name: WATER;(DEMINERALIZED WATER)
% Wt: <100
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: SLIGHTLY TOXIC. CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE REPORTED.
First Aid: EYES/SKIN: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.
INGESTION: GIVE LARGE QUANTITIES OF WATER. CALL MD IMMEDIATELY. INHALATION:
REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN OR ARTIFI CIAL
RESPIRATION) (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DILUTE WITH WATER. POUR DOWN THE DRAIN WITH EXCESS
WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL
REGULATIONS.
Handling And Storage Precautions: STORE TIGHTLY CLOSED IN A COOL, DRY PLACE.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: USE MEDIA SUITABLE FOR SURROUNDING FIRE (FP N).
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NOT DETERMINED.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: NONE SPECIFIED BY MANUFACTURER.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >212F,>100C
Spec Gravity: 1.043
PH: 7.2
Evaporation Rate & Reference: 0.67
Solubility in Water: MISCIBLE
Appearance and Odor: CLEAR AND COLORLESS, NO ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: BACTERIAL CONTAMINATION, EVAPORATION.
Materials To Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: NOT DETERMINED.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: BUFFER SOLUTION PHOSPHATE TYPE, 431
Company: HACH COMPANY
Street: 100 DAYTON RD.
PO Box: 907
City: AMES IA
Zipcode: 50010
Health Emergency Phone: 303-623-5716
Label Required IND: Y
Date Of Label Review: 10/11/1995
Status Code: C
Label Date: 10/11/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: SLIGHTLY TOXIC. CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.