LOCTITE CORPORATION -- SUPER BONDER(R) 495 GENERAL PURPOSE INST ADH
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 00-142-9193
MSDS Num: CDKPH
MSDS NAME: SUPER BONDER(R) 495 GENERAL PURPOSE INST ADH 49550
Responsible Party
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL (FORMALLY IN NEWINGTON) CT 06067
Info Phone: 860-571-5100/FAX 860-571-5465
Emergency Phone Number: 860-571-5100/FAX 860-571-5465
Preparer's Name: STEPHEN REPETTO
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
Phone: 860-571-5100
=======================================================
Item Description Information
=======================================================
Item Manager: GSA
Item Name: ADHESIVE
Specification Number: A-A-6097
Type/Grade/Class: 2 TYPE, 2 CLASS
Unit of Issue: BX
Quantitative Expression: 00000000010EA
UI Container Qty: B
Type of Container: PLASTIC BTL
=======================================================
Ingredients
=======================================================
Cas: 7085-85-0
Name: ETHYL CYANOACRYLATE
% Wt: 95-100
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
------------------------------
Cas: 9011-14-7
RTECS #: TR0400000
Name: POLYMETHYLMETHACRYLATE
% Wt: 3-5
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
------------------------------
Cas: 123-31-9
RTECS #: MX3500000
Name: HYDROQUINONE (SARA 302/313) (CERCLA)
% Wt: 0.1-1
Other REC Limits: NONE RECOMMENDED
OSHA PEL: 2 MG/M3
ACGIH TLV: 2 MG/M3; 9596
EPA Rpt Qty: 1 LB
DOT Rpt Qty: 1 LB
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50 ORAL >5000MG/KG, ESTIMATED
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: SKIN CONTACT MAY CAUSE BURNS.BONDS SKIN RAPIDLY &
STRONGLY.SKIN/EYE IRRIT.
Explanation Of Carcinogenicity: PER MSDS:CARCINOGEN NTP/IARC/
OSHA:NO.
Signs And Symptions Of Overexposure: VAPOR IRRIT EYE & MUCOUS MEMBRANES
ABOVE TLV.PROLONGED & REPEATED OVEREXPO TO VAP MAY PRODUCE SYMPTOMS OF
NON-ALLERGIC ASTHMA IN SENSITIVE INDIVIDUALS.
Medical Cond Aggravated By Exposure: NONE KNOWN. TARGET ORGANS:RESPIRATORY,
BLOOD, BONE MARROW, CNS, EYE, IMMUNE SYSTEM, SKIN.
First Aid: INGEST:NOT LIKELY.INHAL:REMOVE TO FRESH AIR.SYMPT PERSIST GET MED
ATTN.SKIN:REMOVE EXCESS.SOAK IN WARM/SOAPY H2O.ADH COMES LOOSE IN SEVERAL
HRS.CURED ADH NOT HEALTH HAZ WHEN BOND TO SKIN.PEEL/ROLL SUR F APART W/BLUNT
EDGE.DONT PULL SURF APART.EYE:CYANOACRYLATE ATTACH TO PROTEIN.DISASSOCIATE
OVER INTERMITTENT PERS-SEVERAL HRS.WEEPING TO CLEAR ADH.DOUBLE
VISION/LACHRYMATORY EFFECTS.MOUTH(SUPPLEMENTA)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: FLOOD W/WATER TO POLYMERIZE.SOAK UP W/INERT
ABSORBENT.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: POLYMERIZE W/WATER.INCINERATE FOLLOWING EPA & LOC
REGS.NOT A RCRA HAZ WASTE MATL.
Handling And Storage Precautions: STORE @/BELOW 75F.CONTACT LOCTITE CUSTOMER
SERV 1-800-243-4874 FOR SHELF LIFE INFO.AOVID CONTACT W/SKIN/EYES.AVOID
BREATHING VAPOR.
Other Precautions: CYANOACRYLATE ADH VERY FAST SETTING/STRONG ADH.BOND HUMAN
TISSUE INCLUDE SKIN IN SECS.ACCIDENTS HNDLD BEST BY PASSIVE NONSURFICAL
1STAID.CYANOACRYLATES GIVE OFF HEAT ON SOLIDIFICATION-RARE CASE CAUSE
BURN.TREAT NORMALLY AFT ADH REMOVE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 150F,66C
Lower Limits: N/AVAI
Upper Limits: N/AVAI
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures: NONE
Unusual Fire/Explosion Hazard: IRRITATING ORGANIC FRAGMENTS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE SPECIFIED BY MANUFACTURER.
Ventilation: POSITIVE DOWN-DRAFT EXHAUT VENTI SHOULD BE PROVIDE TO MAINTAIN VAP
CONCEN BELOW TLV.
Protective Gloves: NITRILE OR POLYETHYLENE GLOVE;NOT COTTON
Eye Protection: SAF GLASSES OR GOGGLES
Other Protective Equipment: NITRILE OR POLYETHYLENE APRON.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: 1STAID:APPLY LOTS OF WARM H2O W/PRESSURE FRM
SALIVA INSIDE.DONT PULL LIPS APART.ALMOST IMPOSSIBLE TO SWALLOW
CYANOACRYLATE-ADH SOLIDIFIES/ADHERES IN MOUTH.SALIVA LIFTS ADH IN
1/2-2DAYS.LUMP FORMS IN M OUTH POSITION PATIENT TO PREVENT INGESTO LUMP WHEN
DETACHES.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: V4
B.P. Text: >300F,>149C
Vapor Pres: <0.2 @75F
Vapor Density: 3
Spec Gravity: 1.05
PH: NA
Evaporation Rate & Reference: N/AVAI
Solubility in Water: POLYMERIZED BY H2O
Appearance and Odor: CLEAR LIQUID, SHARP, IRRITATING ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: POLYMERIZED BY CONTACT W/WATER,ALCOHOLS,AMINES,ALKALIES.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
Transportation Information
=======================================================
Trans ID NO: 50194
MSDS NAME: SUPER BONDER(R) 495 GENERAL PURPOSE INST ADH 49550
MSDS Prepared Date: 04/15/1997
Review Date: 04/23/1998
Net Unit Weight: 10 X 1 OZ
Multiple KIT Number: 0
Review IND: Y
Unit Of Issue: BX
Container QTY: B
Type Of Container: PLASTIC BTL
Additional Data: PER MSDS:DOT GROUND:UNRESTRICTED(<450L);COMBUSTILE LIQ
NOS(CYANOACRYLATE ESTER)(>450L)NA1993;IATA UN RESTRICTED(<1PT);OTHER
REGULATED SUBSTANCES,CLASS 9, ID8027(>1PT).
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SUPER BONDER(R) 495 GENERAL PURPOSE INST ADH 49550
Company: LOCTITE CORPORATION
Street: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT
Zipcode: 06067-3910
Health Emergency Phone: 860-571-5100\FAX 860-571-5465
Label Required IND: Y
Date Of Label Review: 04/23/1998
Status Code: C
Label Date: 04/23/1998
Origination Code: F
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: SKIN CONTACT CAUSE BURNS.BONDS SKIN
RAPIDLY/STRONGLY.SKIN/EYE IRRIT.1STAID:INGEST:NOT LIKELY.INHAL:REMOVE TO
FRESH AIR.SYMPT PERSIST GET MED ATTN.SKIN:REMOVE EXCESS.SOAK IN WARM/SOAPY
H2O.ADH COMES LO OSE IN SEVERAL HRS.CURED ADH NOT HEALTHHAZ WHEN BOND TO
SKIN.PEEL/ROLL SURF APART W/BLUNT EDGE.DONT PULL SURF APART.EYE:CYANOACRYLATE
ATTACH TO PROTEIN.DISASSOCIATE OVER INTERMITTENT PERS-SEVERAL HRS. WEEPING TO
CLEAR ADH.DOUBLE VISION/LACHRYMATORY EFFECTS.MOUTH-APPLY LOTS OF WARM
H2O/PRESSURE FRM SALIVA INSIDE MOUTH.PEEL/ROL APART-DONT PULL
APART.BURNS:CYANOACRYLATES GIVE OFF HEAT ON SOLIDIFICATIO N.RARE CASES CAUSES
BURN-TREAT NORMALLY.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.