81725, ULTRA BLUE(R) SENSOR-SAFE RTV SILICONE(SUPDAT)
CAS  
:
NAME  
:
*** proprietary ***
LOCTITE CORP -- 81725, ULTRA BLUE(R) SENSOR-SAFE RTV SILICONE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CFSHW
MSDS NAME: 81725, ULTRA BLUE(R) SENSOR-SAFE RTV SILICONE(SUPDAT)
Responsible Party
Name: LOCTITE CORP
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
Info Phone: 860-571-5100
Emergency Phone Number: 860-571-5100
Preparer's Name: STEPHEN REPETTO
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORP
Address: 705 N MT RD
City: NEWINGTON CT 06111
Phone: 312-689-6200
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
Phone: 860-571-5100
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYE AND SKIN IRRITANT. MODERATELY TOXIC BY INGESTION. WHEN
HEATED TO TEMPS >300F (150C) IN PRESENCE OF AIR, THIS PRODUCT CAN FORM
FORMALDEHYDE VAPORS. FORMALDEHYDE IS A POTENTIAL CANCER HAZARD & A KNO WN
SKIN & RESPIRATORY SENSITIZER. VAPORS IRRITATE EYES, NOSE & THROAT.
SAFE HANDLING CONDITIONS MAY BE (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:MAINTAINED BY KEEPING VAP CONCS
BELOW OSHA PEL FOR FORMALDEHYDE. METHYL ETHYL KETOXIME PRDCD DURING CURE IS
TOX & IRRITS EYES, NOSE & THROAT. TARGET ORGS & OTHER HLTH EFTS:
CALCIUM CARBONATE - NUISANCE DUST; POLY(DIMETHYLSILOXANE), DIMETHYL -
IRRITANT. METHYL ETHYL KETOXIME - ALLERGEN, BLOOD, CNS, IRRITANT.
Medical Cond Aggravated By Exposure: DERMATITIS.
First Aid: INGEST:DO NOT INDUCE VOMITING. KEEP INDIVIDUAL CALM. OBTAIN MEDICAL
ATTENTION. INHAL:REMOVE TO FRESH AIR. IF SYMPTOMS PERSIST, OBTAIN MEDICAL
ATTENTION. SKIN:WIPE OFF PASTE W/PAPER TOWEL OR CLOTH. WAS H THOROUGHLY
W/SOAP & WATER. EYES:FLUSHFOR AT LEAST 15 MINUTES W/WATER. OBTAIN MEDICAL
ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: WIPE OR SCRAPE UP SPILLED MATERIAL. MAINTAIN GOOD
VENTILATION FOR LARGE SPILLS. PLACE SCRAP MATERIAL IN A WELL VENTILATED AREA
& ALLOW TO CURE TO RUBBER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). CURED RUBBER CAN BE INCINERATED FOLLOWING EPA & LOCAL
REGULATIONS. NOT AN RCRA HAZARDOUS WASTE MATERIAL.
Handling And Storage Precautions: STORE IN A DRY AREA BELOW 90F. KEEP
CONTAINERS CLOSED WHEN NOT IN USE. AVOID SKIN & EYE CONTACT. AVOID
BREATHING VAPOR.
Other Precautions: (CONTACT LOCTITE CUSTOMER SERVICE 1-800-243-4874 FOR SHELF
LIFE INFORMATION).
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: >200F,>93C
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN (FP N).
Ventilation: PROVIDE LOCAL VENTILATION FOR PROLONGED USE IN A CONFINED AREA.
Protective Gloves: RUBBER OR PLASTIC GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: DO NOT WEAR CONTACT LENSES WHILE APPLYING MATEIRAL.
VAPOR MAY BE TRAPPED UNDER LENS.
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDITIONAL INFORMATION (FP N). MFR'S TRADE NAME/PART NO:GASKET
MAKER.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: <5
Vapor Density: 3
Spec Gravity: 1.3
PH: 7-8
VOC Grams/Liter: 51
Solubility in Water: POLYMERIZED
Appearance and Odor: BLUE PASTE; MILD ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: POLYMERIZED BY CONTACT W/MOISTURE.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: (NON-THERMAL):METHYL ETHYL KETOXIME. HAZ
PRODS FORMED BY FIRE/THERMAL DECOMP:FORMALDEHYDE, SILICA FUMES.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
Other Information: VOLATILE ORGANIC COMPOUNDS (EPA METHOD 24): 3.9%; 50.7 G/L.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 81725, ULTRA BLUE(R) SENSOR-SAFE RTV SILICONE(SUPDAT)
Company: LOCTITE CORP
Street: 705 N MT RD
City: NEWINGTON CT
Zipcode: 06111
Health Emergency Phone: 860-571-5100
Label Required IND: Y
Date Of Label Review: 11/17/1997
Status Code: C
Label Date: 11/17/1997
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE:EYE AND SKIN IRRITANT. MODERATELY
TOXIC BY INGESTION. VAPORS IRRITATE EYES, NOSE AND THROAT. CHRONIC:WHEN
HEATED TO TEMPERATURES ABOVE 300F (150C) IN PRESENCE OF AIR, THIS PRODUCT C
AN FORM FORMALDEHYDE VAPORS. FORMALDEHYDE IS A POTENTIAL CANCER HAZARD AND A
KNOWN SKIN AND RESPIRATORY SENSITIZER. TARGET ORGANS:BLOOD, CENTRAL NERVOUS
SYSTEM.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department