LANIER WORLDWIDE -- 6450, 6550 BLACK TONER
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BTNYM
MSDS NAME: 6450, 6550 BLACK TONER
Responsible Party
Name: LANIER WORLDWIDE
Address: 2300 PARKLAKE DR NE
City: ATLANTA GA 30345-2979
Info Phone: 404-621-1395/800-654-3370
Emergency Phone Number: 800-333-2679/404-621-1395
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: LANIER WORLDWIDE INC
Address: 2300 PARKLAKE DR NE
City: ATLANTA GA 30345-2979
=======================================================
Contractor Summary
=======================================================
Name: LANIER WORLDWIDE INC
Address: 2300 PARKLAKE DR NE
City: ATLANTA GA 30345-2979
Phone: 770-723-4208
Name: OFFICE COMMUNICATION SYSTEMS
Address: UNKNOWN
City: UNKNOWN NK 00000
Phone: UNKNOWN
=======================================================
Ingredients
=======================================================
Name: ORGANIC PIGMENTS
% Wt: 1.5
-----------------------------
Cas: 25085-53-4
Name: POLYPROPYLENE *93-4*
% Wt: 3.5
------------------------------
Cas: 27136-15-8
Name: METHACRYLIC ACID METHYL ESTER, POLYMER W/BUTYL ACRYLATE & STYRENE
*93-4*
% Wt: 88.5
------------------------------
Cas: 1333-86-4
RTECS #: FF5800000
Name: COLUMBIA CARBON, CARBON BLACK, LAMPBLACK, BLACK PEARLS
% Wt: 6.5
Other REC Limits: 3.5 MG/CUM (NIOSH)
OSHA PEL: 3.5 MG/CUM
ACGIH TLV: 3.5 MG/CUM
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHALATION: MINIMUM IRRITATION TO RESPIRATORY TRACT MAY
OCCUR AS W/EXPOSURE TO ANY NON-TOXIC DUST. EYES: MECHANICAL IRRITATION.
INGESTION: POSSIBLE, BUT VERY UNUSUAL.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: INHALATION: MINIMUM IRRITATION TO
RESPIRATORY TRACT MAY OCCUR AS W/EXPOSURE TO ANY NON-TOXIC DUST. EYES:
MECHANICAL IRRITATION. INGESTION: POSSIBLE, BUT VERY UNUSUAL.
Medical Cond Aggravated By Exposure: ACCUMULATION OF DUST IN RESPIRTORY SYSTEM.
First Aid: EYES: FLUSH W/PLENTY OF WATER FOR 5 MINS. SKIN: WASH W/SOAP &
WATER. INHALATION: REMOVE TO FRESH AIR. IF NECESSARY, AID IN BREATHING.
INGESTION: RINSE MOUTH W/WATER. OBTAIN MEDICAL ATTENTION IN ALL CA SES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SWEEP/CLEAN UP W/LANIER APPROVED VACUUM CLEANER.
REMOVE ALL RESIDUE FROM FLOOR AS IT MAY BE SLIPPERY.
Waste Disposal Methods: MAY BE DUMPED/INCINERATED UNDER CONDITIONS WHICH MEET
LOCAL, STATE, & FEDERAL REGULATIONS.
Other Precautions: MINIMIZE BREATHING DUST.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: IN/MACHINE: CO2, DRY CHEMICAL, FOAM. OUTSIDE MACHINE: CO2,
DRY CHEMICAL, FOAM, WATER.
Fire Fighting Procedures: WILL BURN IN CASE OF FIRE.
Unusual Fire/Explosion Hazard: THIS MATERIAL HAS NO UNUSUAL FIRE/EXPLOSION
HAZARDS. AVOID CREATING DUST CLOUD. DON'T DISPERSE IN FIRE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE
Protective Gloves: NONE
Eye Protection: NONE
Other Protective Equipment: NONE
Work Hygienic Practices: WASH W/SOAP & WATER AFTER HANDLING.
=======================================================
Physical/Chemical Properties
=======================================================
M.P/F.P Text: 302F
Spec Gravity: 1.1-1.5
Solubility in Water: NEGLIGIBLE
Appearance and Odor: BLACK FINE POWDER & PRACTICALLY ODORLESS.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE
Materials To Avoid: NONE
Hazardous Decomposition Products: CO, CO2 & NITROGEN OXIDES.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NONE
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 6450, 6550 BLACK TONER
Company: LANIER WORLDWIDE INC
Street: 2300 PARKLAKE DR NE
City: ATLANTA GA
Zipcode: 30345-2979
Health Emergency Phone: 800-333-2679/404-621-1395
Label Required IND: Y
Date Of Label Review: 06/02/1994
Status Code: C
Label Date: 06/02/1994
Origination Code: F
Signal Word: CAUTION
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: INHALATION: MINIMUM IRRITATION TO RESPIRATORY TRACT MAY
OCCUR AS W/EXPOSURE TO ANY NON-TOXIC DUST. EYES:MECHANICAL IRRITATION.
INGESTION: POSSIBLE, BUT VERY UNUSUAL. POSSIBLE LUNG I
RRITAITON FROM SILICA. LONG TERM EXPOSURE TO CRYSTALLINE SILICA CAN CAUSE
PNEUMOCOSIOSIS. CARCINOGEN: QUARTZ.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|