EXXON CO -- SPARTAN SYNTHETIC EP 220, 415443
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXGMM
MSDS NAME: SPARTAN SYNTHETIC EP 220, 415443
Responsible Party
Name: EXXON CO
Box: 2180
City: HOUSTON TX 77252-2180
Info Phone: 713-656-3424
Emergency Phone Number: 713-656-3424
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: EXXON CO
Box: 2180
City: HOUSTON TX 77252-2180
Phone: 713-656-3424
Name: EXXON COMPANY U.S.A.
Box: 2180
City: HOUSTON TX 77252-2180
Phone: 713-656-5949 / 713-656-3424
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50:(ORAL,RAT) >5 G/KG OF BODY WT.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: HLTH STUDIES HAVE SHOWN THAT MANY PETRO HYDROCARBONS &
SYNTHETIC LUBRICANTS POSE POTNTL HUMAN HLTH RISKS WHICH MAY VARY FROM PERS TO
PERS. AS PREC, EXPOS TO LIQS, VAPS, MISTS/FUMES SHOULD BE MINIMIZED .
PRLNG/RPTD SKIN CONT MAY CAUSE IRRIT.PRLNG/RPTD SKIN CONT W/THIS PROD TENDS
TO REMOVE SKIN OIL, POSS(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:LEADING TO IRRIT & DERM;
HOWEVER, BASED ON HUMAN EXPER & AVAIL TOX DATA, THIS PROD IS JUDGED TO BE
NEITHER "CORR" NOR "IRRIT" BY OSHA CRITERIA. PROD CONTACTING EYES MAY CAUSE
IRRIT. PROD HAS LOW ORDER OF ACUTE ORAL & DERMAL TOX, BUT MIN AMTS
ASPIRATED INTO LUNGS DURING INGEST/VOMIT MAY CAUSE MILD TO
Medical Cond Aggravated By Exposure: NONE RECOGNIZED.
First Aid: EYE:FLUSH W/CLEAR WATER FOR AT LST 15 MINS/UNTIL IRRIT SUBSIDES. IF
IRRIT PERSISTS, CALL MD. SKIN:REMOVE ANY CONTAM CLTHG & WASH SKIN W/SOAP
& WATER. LAUNDER/DRY-CLEAN CLTHG BEFORE REUSE. IF PROD IS I NJECTED
INTO/UNDER SKIN/INTO ANY PART OF BODY, REGARDLESS OF APPEAR OF WOUND/ITS
SIZE, INDIVIDUAL SHOULD BE EVALUATED IMMED BY MD AS SURGICAL EMER. EVEN
THOUGH INITIAL SYMPS FROM HIGH PRESS
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: RECOVER FREE PROD. ADD SAND, EARTH/OTHER SUITABLE
ABSORB TO SPILL AREA. MIN BRTHG VAPS. MIN SKIN CONT. OPEN ALL WINDOWS &
DOORS. KEEP PROD OUT OF SEWERS & WATERCOURSES BY DIKING/IMPOUNDING.
ADVISE AUT HS IF PROD HAS ENTERED/MAY ENTER SEWERS,
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N).
Handling And Storage Precautions: KEEP CNTNRS CLSD WHEN NOT IN USE. DO NOT
STORE NEAR HEAT, SPKS, FLAME/STRONG OXIDANTS. IN ORDER TO PVNT FIRE/EXPLO
HAZS, USE APPROP EQUIP.
Other Precautions: INFO ON ELEC EQUIP APPROP FOR USE W/THIS PROD MAY BE FOUND
IN LATEST EDITION OF NEC (NFPA-70). THIS DOCUMENT IS AVAIL FROM NFPA,
BATTERYMARCH PARK, QUINCY, MA 02269. MIN BRTHG VAP, MIST/FUMES. AVOID P
RLNG/RPTD CONT W/SKIN. THIS PROD
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: >475F,>246C
Extinguishing Media: FOAM, WATER SPRAY (FOG), DRY CHEM, CARBON DIOXIDE &
VAPORIZING LIQ TYPE EXTING AGENTS MAY ALL BE SUITABLE FOR (SUPDAT)
Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP(FP
N). USE WATER TO KEEP FIRE-EXPOS CNTNRS COOL. IF LEAK/SPILL HAS NOT IGNITED,
USE WATER SPRAY TO DISPERSE
Unusual Fire/Explosion Hazard: USE PRODUCT W/CAUTION AROUND HEAT, SPARKS, PILOT
LIGHTS, STATIC ELECTRICITY & OPEN FLAME.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED SUPPLIED-AIR RESPIRATORY
PROTECTION IN CONFINED OR ENCLOSED SPACES, IF NEEDED.
Ventilation: USE LOC EXHST TO CAPTURE VAP, MISTS/FUMES, IF NEC. PROVIDE VENT
SUFFICIENT TO PVNT EXCEEDING REC EXPOS LIMIT/
Protective Gloves: CHEMICAL-RESISTANT GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). USE CHEM-RESIST APRON/OTHER IMPERVIOUS
Work Hygienic Practices: REMOVE CONTAM CLTHG; LAUNDER/DRY-CLEAN BEFORE RE-USE.
REMOVE CONTAM SHOES & THORO CLEAN BEFORE RE-USE; DISCARD
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EXTING MEDIA:EXTING FIRES INVOLVING THIS TYPE
OF PROD, DEPENDING ON SIZE/POTNTL SIZE OF FIRE & CIRCUMSTANCES RELATED TO
SIT UATION. PLAN FIRE PROT & RESPONSE STRATEGY THRU CONSULTATION W/LOC
FIRE PROT AUTHS/APPROP SPECIALISTS.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 700F,371C
M.P/F.P Text: -65F,-54C
Vapor Pres: <0.01@ 20C
Vapor Density: >5
Spec Gravity: 0.83
PH: NEUT
Solubility in Water: NEGLIGIBLE;
Appearance and Odor: CLEAR LIQUID, AMBER COLOR; MILD PUNGENT ODOR.
Percent Volatiles by Volume: NEGLIG
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: USE PRODUCT W/CAUTION AROUND HEAT, SPARKS, PILOT
LIGHTS, STATIC ELECTRICITY & OPEN FLAME.
Materials To Avoid: AVOID CONT W/STRONG OXIDANTS SUCH AS LIQ CHLORINE,
CONCENTRATED OXYGEN, SODIUM HYPOCHLORITE, CALCIUM HYPOCHLORITE, ETC.
Hazardous Decomposition Products: FUMES, SMOKE, CARBON MONOXIDE, SULFUR OXIDES,
ALDEHYDES & OTHER DECOMP PRODS, IN THE CASE OF INCOMPLETE COMBUSTION.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SPARTAN SYNTHETIC EP 220, 415443
Company: EXXON CO
PO Box: 2180
City: HOUSTON TX
Zipcode: 77252-2180
Health Emergency Phone: 713-656-3424
Label Required IND: Y
Date Of Label Review: 04/25/1995
Status Code: C
Label Date: 04/25/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE:SKIN/EYES:IRRITATION.
CHRONIC:SKIN:IRRITATION, DERMATITIS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|