PACIFIC CHEMICAL -- IEC 600 DEFLOCCULANT
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXGPZ
MSDS NAME: IEC 600 DEFLOCCULANT
Responsible Party
Name: PACIFIC CHEMICAL
Address: 500 7TH AVE SOUTH
Box: 558
City: KIRKLAND WA 98083
Info Phone: 206-827-8711
Emergency Phone Number: 800-424-9300 (CHEMREC)
Preparer's Name: E H BRANDLI
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: PACIFIC CHEMICAL COMPANY
Address: UNKNOWN
City: UNKNOWN NK 00000
Phone: UNKNOWN
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: NO
Effects of Exposure: INHAL: DUST GENERATED DURING DISPENSING MAY CAUSE
SNEEZING. EYE: IRRIT & ABRASION POSSIBLE ON PROLONGED CONTACT. SKIN:
MINOR SKIN IRRIT POSSIBLE ON PROLONGED CONTACT. INGEST: SMALL AMOUNTS ARE
HARMLES S; SIZABLE INGESTION MAY CAUSE NAUSEA.
Explanation Of Carcinogenicity: CRYSTALLINE, SILICA-QUARTZ: IARC MONOGRAPHS,
SUPP. VOL 7, PG 341, 1987: GROUP 2A. NTP 7TH ANNUAL RPT ON CARCINS(SUPDAT)
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYE: IMMED FLUSH EYES W/WATER FOR AT LEAST 15 MINUTES & GET MED
ATTN. SKIN: WATER RINSE. INHAL: BLOW NOSE TO EJECT DUST WHICH GENERALLY
ENTRAPPED AS A PASTY MASS. INGEST: CONSULT MD IF NAUSEA OCCURS.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SWEEP UP & RECLAIM OR PACKAGE FOR DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN APPROVED WASTE DISPOSAL FACILITY
ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
Handling And Storage Precautions: DISPENSE CAREFULLY TO MINIMIZE DUST
GENERATION.
Other Precautions: IEC 600 PROVIDES INSIGNIFICANT HAZARDS OR TOXICITY UNDER
USAGE CONDITIONS. PROLONGED INHAL OF ITS DUST, READILY AVOIDED, MAY BE TOXIC
DUE TO ITS SMALL SILICA CONTENT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: NONFLAMMABLE
Extinguishing Media: USE MEDIA SUITABLE FOR SURROUNDING FIRE(FP N).
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT(FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE A NIOSH/MSHA APPROVED DUST RESPIRATOR.
Ventilation: LOCAL EXHAUST/MECHANICAL: NORMAL.
Protective Gloves: IMPERVIOUS GLOVES(FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS(FP N).
Other Protective Equipment: NOT NEEDED.
Work Hygienic Practices: NORMAL.
Supplemental Safety and Health: EXPLAN OF CARCIN: 1994: ANTICIPATED TO BE
CARCINOGENS.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: 0
Vapor Density: 0
Spec Gravity: 1 (H*2O=1)
Evaporation Rate & Reference: 0(BUAC=1)
Appearance and Odor: GRAY/TAN POWDER W/NO ODOR.
Percent Volatiles by Volume: 0
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: SLOW CORROSIVE ACTION ON ALUMINUM.
Hazardous Decomposition Products: NONE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: IEC 600 DEFLOCCULANT
Company: PACIFIC CHEMICAL COMPANY
Street: UNKNOWN
City: UNKNOWN NK
Zipcode: 00000
Health Emergency Phone: 800-424-9300 (CHEMREC)
Label Required IND: Y
Date Of Label Review: 04/26/1995
Status Code: C
Label Date: 04/26/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: INHAL: DUST GENERATED DURING DISPENSING MAY
CAUSE SNEEZING. EYE: IRRIT & ABRASION POSSIBLE ON PROLONGED CONTACT.
SKIN: MINOR SKIN IRRIT POSSIBLE ON PROLONGED CONTACT. INGEST: SMALL AMOUNTS
ARE HARMLESS; SIZABLE INGESTION MAY CAUSE NAUSEA. CHRONIC: CANCER HAZARD.
CONTAINS CRYSTALLINE-SILICA QUARTZ WHICH IS LISTED AS A CARCINOGEN(FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.