INTERNATIONAL PAINT -- INTERTUF LTC EPOXY REACTOR, KLA053
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXGSW
MSDS NAME: INTERTUF LTC EPOXY REACTOR, KLA053
Responsible Party
Name: INTERNATIONAL PAINT
Address: 2270 MORRIS AVE
City: UNION NJ 07083-0386
Info Phone: 800-223-0154
Emergency Phone Number: 713-682-1711
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: INTERNATIONAL PAINT INC
Address: 6001 ANTOINE DR
City: HOUSTON TX 77091
Phone: 800-589-1267/800-854-6813
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
=======================================================
Handling and Disposal
=======================================================
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: 98.0F,36.7C
Lower Limits: 1.4%
Extinguishing Media: FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). SMOTHER FLAMES W/ONE OF THE EXTING MEDIA. WATER MAY BE USED TO COOL
UNOPENED CONTRS, BUT MUST (SUP DAT)
Unusual Fire/Explosion Hazard: CONTAINS FLAMMABLE SOLVENT. DO NOT USE IN AREAS
WHERE SPARKS OR OPEN FLAME ARE PRESENT. FLAMMABLE OSHA CLASS IC.
=======================================================
Control Measures
=======================================================
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 244F,118C
Vapor Pres: (SEE INGS)
Vapor Density: HVR/AIR
Spec Gravity: 0.946 (FP N)
Evaporation Rate & Reference: SLOWER THAN ETHER
Appearance and Odor: NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume: 30
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: STORE AWAY FROM DIRECT HEAT, FLAME OR SPARK.
Materials To Avoid: OXIDIZING AGENTS.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: INTERTUF LTC EPOXY REACTOR, KLA053
Company: INTERNATIONAL PAINT INC
Street: 6001 ANTOINE DR
City: HOUSTON TX
Zipcode: 77091
Health Emergency Phone: 713-682-1711
Label Required IND: Y
Date Of Label Review: 05/02/1995
Status Code: C
Label Date: 05/02/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Severe
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: FLAMMABLE OSHA CLASS IC. ACUTE: EYES: SEVERE IRRITATION
WITH REDNESS, TEARING AND BLURRED VISION. SKIN: SEVERE IRRITATION. MAY CAUSE
BURNS. INHALATION: IRRITATION OF RESPIRATORY TRACT. HEADACHE, DIZZI NESS
& UNCONSCIOUSNESS. INGESTION: GASTROINTESTINAL IRRITATION, NAUSEA,
VOMITING, DIARRHEA. CHRONIC: SOLVENTS HAVE BEEN LINKED TO PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.