LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF OVEREXPOSURE
SECTION .
Explanation of Carcinogenicity:METHYLENE CHLORIDE:ACGIH:SUSPECTED HUMAN
CARCINOGEN,NOTICE OF INTENDED CHANGES .
Effects of Overexposure:DIZZINESS AND LOSS OF CONSCIOUSNESS.
Medical Cond Aggravated by Exposure:N/K
======================= First Aid Measures =======================
Eyes:FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MIN AND GET MEDICAL ATTENTION. INHALATION:REMOVE FROM
CONTAMINATED AREA.SUPPORT BREATHING (GIVE O*2/ARTIFICIAL
RESPIRATION). INGES TION:CALL MD IMMEDIATELY . SKIN:FLUSH SKIN WITH
SOAP AND WATER,FOLLOWED BY ICED ALCOHOL AND GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:CO*2, FOAM, DRY CHEM
Fire Fighting Procedures:WEAR PRESSURE DEMAND SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE EQUIPMENT.KEEP DRUMS COOL.
Unusual Fire/Explosion Hazard:HCL AND PHOSGENE FORMED FROM CHLORINATED
SOLVENT AT EXTREMELY HIGH TEMPERATURES.
Spill Release Procedures:ABSORB ON FLOOR DRY MATL & ALLOW SOLVENT TO
EVAPORATE. DISPOSE RESIDUE TO SOLID WASTE.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE BELOW 100F. OPEN BUNGS SLOWLY TO
DISSIPATE ANY SOLVENT PRESSURE.
Other Precautions:NO SMK IN AREA OF USE.DO NOT USE IN GEN VICINITY OF
ARC WELD,OPEN FLAME/HOT SURFACE.HEAT &/UV RADIATION MAY CAUSE FORM
OF HCL &/PHOSGENE.CAUTION-MAY DISPLACE OXYGEN IN ENCLOSED/CONFINED
SPACES.G AS VAPORS MAY ACCUMULATE IN LOW AREA-FPN
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST AT WORK SITE.
Protective Gloves:SOLVENT RESISTANT
Eye Protection:CHEM WORK GOGGLES,FACE SHIELD OPTION-FPN
Other Protective Equipment:BOOTS/APRON WHEN WORKING W/SPIRIT
Work Hygienic Practices:N/K
Supplemental Safety and Health
PH:N.RT OF ENTRY:ACCORDING TO MFG:TLV FOR PRODUCT IS 300 TO 350 PPM.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.