Search   
MSDS  : TOLUENE
CAS  : 108-88-3
NAME  : toluene (sara iii)
===================== Product Identification =====================

MSDS NAME:TOLUENE
NIIN:00-223-9073
MSDS Number: BQKNF
=== Responsible Party ===
Company:MATHESON GAS PRODUCTS
Address:30 SEAFIEW DRIVE
City:SEACAUCUS
State:NJ
ZIP:07096
Country:US
Info Phone Num:201-867-4100
Emergency Phone Num:201-867-4100, CHEMTREC 800-424-9300
CAGE:0FB11
=== Contractor Identification ===
Company:MATHESON GAS PRODUCTS
Address:30 SEAFIEW DRIVE
Box:City:SEACAUCUS
State:NJ
ZIP:07096
Country:US
Phone:201-867-4100, CHEMTREC 800-424-9300
CAGE:0FB11

============= Composition/Information on Ingredients =============

Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 100.0%
Other REC Limits:NONE SPECIFIED BY M.
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

===================== Hazards Identification =====================

LD50 LC50 Mixture:LD50 (ORAL RAT) IS 5 GM/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION MAY CAUSE IRRITATION OF THE
RESPIRATORY TRACT. SWALLOWING MAY CAUSE ABDOMINAL SPASMS.
ASPIRATION INTO THE LUNGS CAN CAUSE CHEMICAL PNEUMONITIS, WHICH MAY
BE FATAL. SKIN CONTACT MAY CAUSE IR RITATION. EYE CONTACT MAY CAUSE
IRRITATION, REDNESS, & TEARING. CHRONIC: KIDNEYS & LIVER DAMAGE.
Explanation of Carcinogenicity:THIS PRODUCT IS NOT LISTED BY IARC, NTP
OR OSHA AS A CARCINOGEN, MUTAGEN, TERATOGEN OR NEUROTOXIN.
Effects of Overexposure:SYMPTOMS INCLUDE FATIGUE, CONFUSION, HEADACHE,
DIZZINESS AND DROWSINESS. PECULIAR SKIN SENSATIONS (PINS AND
NEEDLES) OR NUMBNESS MAY BE PRODUCED. VERY HIGH CONCENTRATIONS MAY
CAUSE UNCONSCIOUSNESS AND DEATH.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
DISORDERS OR IMPAIRED LIVER OR KIDNEY FUNCTION MAY BE MORE
SUSCEPTIBLE TO THE EFFECTS OF THIS SUBSTANCE. ALCOHOLIC BEVERAGE
CONSUMPTION CAN ENHANCE ITS TOXIC EFFECTS.

======================= First Aid Measures =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE MOUTH- TO-MOUTH
RESUSCITATION IF NOT BREATHING. GIVE OXYGEN IF BREATHING IS
DIFFICULT. GET MEDICAL ATTENTION. EYES: FLUSH WITH RUNNING WATER
FOR 15 MINUTES WHILE HOLDING EYELID. GET MEDICAL ATTENTION. SKIN:
WASH WITH PLENTY OF SOAP & WATER. REMOVE CONTAMINATED CLOTHING. GET
MEDICAL ATTENTION. INGESTED: DO NOT INDUCE VOMITING. GET MEDICAL
ATTENTION IMMEDIATELY.

===================== Fire Fighting Measures =====================

Flash Point Method:CC
Flash Point:40.0F,4.4C
Autoignition Temp:Autoignition Temp Text:896F
Lower Limits:1.1
Upper Limits:7.1
Extinguishing Media:DRY CHEMICAL, FOAM OR CARBON DIOXIDE. WATER MAY BE
USED TO FLUSH SPILLS AWAY FROM EXPOSURES AND TO DILUTE SPILLS.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:ABOVE FLASH POINT, VAPOR AIR MIXTURES ARE
EXPLOSIVE WITHIN FLAMMABLE LIMITS . CONTACT WITH STRONG OXIDIZERS
MAY CAUSE FIRE AND EXPLOSIONS.

================== Accidental Release Measures ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. USE NON-
SPARKING TOOLS AND EQUIPMENT. WEAR PROTECTIVE CLOTHING AND SCBA.
CONTAIN AND RECOVER LIQUID FOR RECLAMATION WHEN POSSIBLE. DO NOT
FLUSH TO SEWER. SMALL SPILLS MAY BE ABSORPED WITH INERT MATERIAL
OR PAPER TOWEL
Neutralizing Agent:NOT APPLICABLE.

====================== Handling and Storage ======================

Handling and Storage Precautions:PROTECT AGAINST PHYSICAL DAMAGE. STORE
IN A COOL, DRY WELL-VENTILATED LOCATION, AWAY FROM ANY AREA WHERE
THE FIRE HAZARD MAY BE ACUTE.
Other Precautions:OUTSIDE OR DETACHED STORAGE IS PERFERRED. SEPARATE
FROM OXIDIZING MATERIALS. CONTAINERS SHOULD BE BONDED AND GROUNDED
FOR TRANSFERS TO AVOID STATIC SPARKS. STORAGE AND USE AREAS SHOULD
BE NO SMOKING A REAS. USE NON-SPARKING TYPE EQUIPMENT.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:IF THE TLV IS EXCEEDED, A HALF MASK CHEMICAL
CARTRIDGE RESPIRATOR MAY BE WORN UP TO TEN TIMES THE TLV OR THE
MAXIMUM USE CONCENTRATION SPECIFIED BY THE RESPIRATOR SUPPLIER,
WHICHEVER IS LESS.
Ventilation:A SYSTEM OF LOCAL AND/OR GENERAL EXHAUST IS RECOMMENDED TO
KEEP EMPLOYEE EXPOSURES BELOW THE AIRBORNE EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS
Eye Protection:CHEMICAL SAFETY GOGGLES W/FACE SHIELD
Other Protective Equipment:IMPERVIOUS PROTECTIVE CLOTHING, INCLUDING
BOOTS, LAB COAT, APRON OR COVERALLS TO PREVENT SKIN CONTACT.
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE WHILE WORKING WITH
THIS PRODUCT.
Supplemental Safety and Health
LOCAL EXHAUST VENTILATION IS GENERALLY PREFERRED BECAUSE IT CAN CONTROL
THE EMISSIONS OF THE CONTAMINANT AT ITS SOURCE. CONTACT LENSES
SHOULD NOT BE WORN WHEN WORKING WITH THIS MATERIAL. MAINTAIN EYE
WASH FOUNTAIN AND QUICK-DRENCH FACILITIES IN WORK AREA. REPORTABLE
QUANTITY (RQ) IS 1000 LBS.

================== Physical/Chemical Properties ==================

HCC:F2
Boiling Pt:B.P. Text:231F,111C
Melt/Freeze Pt:M.P/F.P Text:-139F,-95C
Vapor Pres:22
Vapor Density:3.14
Spec Gravity:0.87
Evaporation Rate & Reference:2.24 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH AN AROMATIC ODOR.
Percent Volatiles by Volume:100

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG MINERAL ACIDS, MITROGEN TETRAOXIDE.
WILL ATTACK SOME FORMS OF PLASTIC AND RUBBER.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:TOXIC GASES AND VAPORS (E.G. CARBON
MONOXIDE AND CARBON DIOXIDE) MAY BE RELEASED IN A FIRE INVOLVING
TOLUENE.

==================== Disposal Considerations ====================

Waste Disposal Methods:MAY BE ATOMIZED IN A SUITABLE RCRA APPROVED
COMBUSTION CHAMBER. ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
FORMA-SCENT 50-00-0
67-56-1
10049-21-5
7558-79-4
119-36-8
7732-18-5
NITROBID CAPSULES 9 MG 55-63-0
62-42-3
URINAL SCREENS
ETHYLENEDIAMINETETRAACETIC ACID TETRASODIUM 10378-23-1
B-NAPHTHYLAMINE ISOPAC 91-59-8
12704 DEPROTEINIZING SOLUTION 7681-52-9
KODAK FLEXICOLOR RA BLEACH REPLENISHER NR (WORKING SOLUTION) 7732-18-5
11687-36-6
12124-97-9
6484-52-2
64-19-7
ILLUMINATING MANTLE
ETHYLENE GLYCOL 107-21-1
340, 340BIL (MIL-P-24377A) 12001-29-5
LEAK DETECTOR MIL-L-25567D
00958 MARFAX MULTI PURPOSE 2 64742-65-0
7620-77-1
64741-95-3
BENZALDEHYDE 100-52-7
872-N, DESICCANT CARTRIDGE
BISMUTH, B-319 7440-69-9
ETHYLENEDIAMINE 107-15-3
ETHYL ALCOHOL, 95% 64-17-5
7732-18-5
AMMONIUM OXALATE MONOHYDRATE 6009-70-7
SHELL SOL 142HT 64742-88-7
CUPRIC SULFATE,ACS OR USP GRADE 7758-99-8
METHYLENE CHLORIDE 75-09-2
DICHLOROMETHANE 75-09-2
ARGON 7440-37-1
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
METHYL PURPLE CAPSULES 4210 28631-66-5
493-52-7
1H6810-00-145-0279X2 BUFFER, PH10 533-96-0
STANNOUS CHLORIDE 7772-99-8
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
SULFURIC ACID 7664-93-9
7732-18-5
HYDROGEN PEROXIDE TOPICAL SOLUTION, (USP) 3 7722-84-1
NITROGEN, COMPRESSED GAS 7727-37-9
1,4-DIOXANE 123-91-1
LIQUID CAUSTIC SODA 50% 1310-73-2
7732-18-5
ACETONE 67-64-1
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
BRAYCOTE 610 (MIL-G-10924)
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
AQUA AMMONIA 7664-41-7
7732-18-5
TOLUENE 108-88-3
ISOPROPYL ALCOHOL (ISOPROPANOL) 67-63-0
ISOPROPYL ALCOHOL (ISOPROPANOL) 67-63-0
TECTYL 802 A (DORD) 64742-52-5
DUCT BOARD 65997-17-3
25104-55-6
HYDROGEN PEROXIDE (30-50%),11189,H 323 500 7722-84-1
7732-18-5
CAF 9,ASBESTOS SHEET,COMPRESSED 12001-29-5
POTASSIUM HYDROXIDE 1310-58-3
SODIUM SULFIDE, 9-HYDRATE 1313-82-2
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
SODIUM BICARBONATE 144-55-8
MERCURIC CHLORIDE, M155 7487-94-7

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net