===================== Product Identification =====================
MSDS NAME:021931-000 NICKEL CADMIUM AIRCRAFT BATTERY
NIIN:01-020-7288
MSDS Number: BXYDT
=== Responsible Party ===
Company:SAFT AMERICA INC, POWER SOURCES DIV
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31603
Country:US
Info Phone Num:912-247-2331/FAX 912-245-2880
Emergency Phone Num:912-247-2331/800-424-9300(CHEMTREC)
CAGE:09052
=== Contractor Identification ===
Company:SAFT AMERICA INC.
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31602
Country:US
Phone:912-247-2331
CAGE:09052
============= Composition/Information on Ingredients =============
Name:NICKEL OXIDE
CAS:1313-99-1
RTECS #:QR8400000
Fraction by Wt: 18%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3 AS NI
ACGIH TLV:1 MG/M3 AS NI
Name:POTASSIUM HYDROXIDE (CERCLA)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 19%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:CADMIUM OXIDE (SARA 302/313) (CERCLA)
CAS:1306-19-0
RTECS #:EV1925000
Fraction by Wt: 13%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG (CD)/M3 DUST
ACGIH TLV:0.01 MG(CD)/M3; 9495
Name:COPPER (SARA 313) (CERCLA)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: 9%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.1MG/M3 FUME/1 DUST
ACGIH TLV:0.2 MG/M3 FUME; 9495
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:NYLON 11
CAS:25587-80-8
Fraction by Wt: 15%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: CONTACT WITH ELECTROLYTE MAY
CAUSE BURNS/SEVERE IRRITATION TO SKIN & EYES. SKIN CONTACT WITH
NICKEL MAY CAUSE IRRITATION. INGESTION OF ELECTROLYTE MAY CAUSE
TISSUE DAMAGE TO THROAT, MOUTH, GI T RACT. INHALATION OF
ELECTROLYTE MIST/VAPOR MAY CAUSE RESPIRATORY IRRITATION. CHRONIC:
SEE SUPPLEMENTAL DATA.............
Explanation of Carcinogenicity:CONTAINS CADMIUM [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN AND
NICKEL.
Effects of Overexposure:INHALED-DRY THROAT, COUGH, HEADACHE, VOMITING,
CHEST PAIN, CHILLS, BREATHING DIFFICULTY, PROSTRATION.
INGESTED-NAUSEA, VOMITING, DIARRHEA, BURNING/PAIN IN
MOUTH/THROAT/STOMACH. SKIN-IRRITATION, REDNES S, BURNS.
EYES-IRRITATION, BURNS, PAIN,TEARING, REDNESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYES-FLUSH WITH LOTS OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. SKIN-REMOVE CONTAMINATED CLOTHES & FLUSH
AFFECTED AREAS FOR AT LEAST 15 MINUTES. INGESTED-DO NOT INDUCE
VOMITING! IF CONSC IOUS, DILUTE WITH WATER OR MILK. GET IMMEDIATE
MEDICAL ATTENTION. INHALED-REMOVE TO FRESH AIR. GIVE OXYGEN OR
ARTIFICIAL RESPIRATION AS NEEDED. GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:CARBON DIOXIDE, SAND.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE GEAR. DISCOMNNECT OR CUT ALL CABLES TO AND FROM
BATTERY.
Unusual Fire/Explosion Hazard:ELECTROLYTE SOLUTION REACTS WITH ZINC,
ALUMINUM, TIN & OTHER REACTIVE METALS TO FORM FLAMMABLE HYDROGEN
GAS. CADMIUM FUMES MAY BE RELEASED IN FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:ELECTROLYTE-FLUSH WITH WATER AND NEUTRALIZE
WITH DILUTE CITRIC ACID. CONTAIN SPILLED MATERIAL. DO NOT ALLOW
INTO STREAMS, SEWERS OR STORM CONDUITS. RECOVER MATERIAL AND
DISPOSE OF PROPERLY. REPORTABL E QUANTITY (CERCLA)=1000 LBS-40 CFR
117.13.
Neutralizing Agent:DILUTE CITRIC ACID.
====================== Handling and Storage ======================
Handling and Storage Precautions:CELLS/BATTERIES MAY BE HIGHLY CHARGED
& CAPABLE OF HIGH ENERGY DISCHARGE. CARE SHOULD BE TAKEN TO HANDLE
CELLS PROPERLY TO AVOID SHORT.
Other Precautions:DO NOT TRANSPORT BATTERIES WITHOUT VENT CAP IN PLACE.
DO NOT ALLOW AN EXPOSED FLAME OR SPARK TO COME NEAR THE CELLS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
APPROVED RESPIRATOR WITH ORGANIC VAPOR CARTRIDGE OR AN AIR-SUPPLIED
RESPIRATOR OR SCB A, AS REQUIRED. USE IAW 29 CFR 1910.134.
Ventilation:WELL VENTILATED AREA WHEN PERFORMING LEVEL CHARGING
PROCEDURES TO REMOVE NORMAL GASES GENERATED.
Protective Gloves:WATER-INSOLUBLE NON-PERMEABLE (RUBBER)
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:URBBER BOOTS, RUBBER APRON OR RAINWEAR OR
EQUIVALENT IF EXPO TO ELECTROLYTE IS POSSIBLE. DO NOT USE LEATHER
OR WOOL.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
CHRONIC HEALTH: PROLONGED OR REPEATED EXPSOURE MAY CAUSE
DERMATITIS/NICKEL ITHCH, PULMONARY EDEMA, KIDNEY DAMAGE, CANCER.
================== Physical/Chemical Properties ==================
HCC:B1
Spec Gravity:1.25-1.30
Evaporation Rate & Reference:NOT DETERMINED
Solubility in Water:COMPLETE
Appearance and Odor:BATTERY, 20 VOLTS/53 AMP-HR, WET CHARGED; 9.8 X
11.56 X 9.1 INCHES.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALUMINUM,ZINC,TIN,OTHER ACTIVE METALS;ACID,CHLORINATED/AROMATIC
HYDROCARBONS,NITROCARBONS,HALOCARBONS,TRICHLOROETHYLENE.
Stability Condition to Avoid:DO NOT ADD SULFURIC ACID.
Hazardous Decomposition Products:NICKEL OXIDE;CADMIUM,CADMIUM
OXIDE,POTASSIUM HYDROXIDE.NOTE:NORMAL REACTIONS IN BATTERY RELEASE
FLAMMABLE HYDROGEN GAS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:STORAGE BATTERY IS HAZ WASTE UNDER RCRA. IT MAY
BE RETURED TO SAFT FOR RECYCLING. BATTERY IS TCLP TOXIC. BATTERY &
ELECTROLYTE SOLUTION ARE CORROSIVE. IF NOT RECYCLED MUST BE
DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
| ALL PAGES On Chemical Property IN THIS GROUP
| | NAME | CAS |
|
NICAD STORAGE BATTERY
| |
PHILLYBOND #6 HARDNER
| 32610-77-8 112-24-3 108-95-2 |
PHILLYBOND #6 RESIN
| 25068-38-6 |
|
OMEGA 2153A SN 313-3
| 75-09-2 67-56-1 108-88-3 |
|
S76 COMPRESSED RUBBER=BONDED ASBESTOS GASKET SHEET
| 12001-29-5 |
|
VARGLAS SILICONE RESIN 500
| |
|
TURCOAT ALUMIGOLD
| 16871-71-9 1333-82-0 10043-35-3 |
|
ELECTRON VACUUM TUBE(S)
| 7440-33-7 |
|
321 DRY FILM LUBRICANT (AEROSOL)
| 7782-42-5 9022-96-2 1317-33-5 8052-41-3 68476-86-8 |
CAMCO QUIK STAIN & QUIK STAIN II
| 67-56-1 |
|
400009-342 PRY PASTE
| 144-62-7 |
PHENOLPHTHALEIN INDICATOR
| 7647-14-5 77-09-8 |
BROMCRESOL GREEN-METHYL RED
| 7447-40-7 |
|
MERCURIC OXIDE CELL
| 1310-58-3 21908-53-2 7439-97-6 7440-66-6 1313-13-9 |
|
BATTERY DRY BA-51/U (BA-3051/U)
| 7439-97-6 7646-85-7 12125-02-9 1313-13-9 1333-86-4 |
|
SPADNS REAGENT FOR FLUORIDE,444-11
| 7647-01-0 7784-46-5 7732-18-5 |
|
930-A LUBRIPLATE
| |
|
11961,FORMALDEHYDE
| 50-00-0 67-56-1 7732-18-5 |
|
021931-000 NICKEL CADMIUM AIRCRAFT BATTERY
| 1313-99-1 1310-58-3 1306-19-0 7440-50-8 25587-80-8 |
|
SUPER QUADROLUBE 75W GEAR LUBRICANT
| 64742-53-6 64741-88-4 68649-42-3 |
|
SMC-772052 NICKEL CADMIUM SEALED CELL BATTERY
| 7440-43-9 21041-95-2 1306-19-0 7440-02-0 12054-48-7 1313-99-1 1310-58-3 7440-48-4 |
|
2018;2018T;LECTRA CLEAN AEROSOL
| 79-01-6 106-88-7 124-38-9 |
|
310 LIME
| 7439-89-6 7440-02-0 7439-96-5 7440-47-3 7782-41-4 471-34-1 7440-21-3 10006-28-7 |
|
P-755715-870 LIQUI-JET 2 DETERGENT
| 7732-18-5 64-02-8 1344-09-8 1310-58-3 |
|
BUFFER SOLUTION PH 7.0 (COLOR-CODED YELLOW),41138,SB-107-500
| 64-02-8 1310-73-2 7732-18-5 7778-77-0 |
|
68702,69702,68745,69704 SHELL DIALA(R) OIL AX
| 64742-46-7 64742-53-6 128-37-0 |
MOBIL SHC 634
| |
|
PRY GEL
| 144-62-7 57-55-6 8006-54-0 |
|
2594 HEMA-CHEK CONTROL
| |
|
2594 HEMA-CHEK SLIDE PAK
| |
|
2594 HEMA-CHEK DEVELOPER
| 67-56-1 7722-84-1 |
|
1596 HEMA-CHEK DEVELOPER
| 67-56-1 7722-84-1 |
|
186 5013 KODAK CINEFLURE FIXER/REPLENISHER, PART A
| 7783-18-8 7732-18-5 127-09-3 10192-30-0 10043-35-3 64-19-7 7631-90-5 |
|
186 5013 KODAK CINEFLURE FIXER/REPLENISHER, PART B
| 7732-18-5 10043-01-3 7664-93-9 |
|
DL2032 LITHIUM MNO2 BATTERY
| 7439-93-2 1313-13-9 7440-44-0 108-32-7 110-71-4 7791-03-9 |
|
E-CR2032 ENERGIZER, LITHIUM-MANGANESE DIOXIDE BATTERY
| 1333-86-4 110-71-4 646-06-0 7439-93-2 7791-03-9 33454-82-9 1313-13-9 108-32-7 |
|
ISOVUE-M 200
| 60166-93-0 7732-18-5 77-86-1 62-33-9 7647-01-0 |
|
GASKET MATERIAL TYPE TBA 510 BLACK
| 12001-29-5 |
MIL-L-81352A COMP.L #36320
| 1330-20-7 13463-67-7 14807-96-6 110-43-0 78-93-3 |
|
BATTERY WET, FILLED WITH ACID, 8, UN2794, PGIII
| 7439-92-1 7664-93-9 7440-36-0 |
|
COMP A, MIL-P-23377, TY II, CL C
| 1330-20-7 100-41-4 64046-64-6 107-87-9 7789-06-2 64742-95-6 |
|
COMP B, MIL-P-2377, TY II, CL 2
| 68410-23-1 140-31-8 71-36-3 64742-95-6 1760-24-3 90-72-2 |
|
CYCLON SEALED LEAD BATTERY
| 7439-92-1 1309-60-0 7664-93-9 |
|
CADNICA NICKEL CADMIUM BATTERY
| 7440-43-9 21041-95-2 7440-02-0 12054-48-7 1310-58-3 |
|
F41-6931-000 CLC-500/550 TONER YELLOW
| 39382-25-7 72869-85-3 |
|
FREEZ-IT 2000, P/N ES1050, ES1250, ES1550
| 811-97-2 |
|
3:1, CAT, MIL-C-85285B, 36081, TYPE I
| 4035-89-6 28182-81-2 64742-95-6 64046-64-6 763-69-9 |
|
3:1, MIL-C-85285, 36081, TY I
| 64046-64-6 763-69-9 1330-20-7 100-41-4 108-88-3 26376-86-3 77-58-7 123-54-6 107-87-9 108-10-1 |
|
HARRIS HEMATOXYLIN (ACIDIFIED)
| 64-19-7 7784-26-1 7681-55-2 |
|
HARRIS HEMATOXYLIN CYTOLOGY/HISTOLOGY STAIN
| 7732-18-5 10043-67-1 64-17-5 64-19-7 21908-53-2 |
|
|