Search   
MSDS  : CADNICA NICKEL CADMIUM BATTERY
CAS  : 7440-43-9
21041-95-2
7440-02-0
12054-48-7
1310-58-3
NAME  : cadmium (sara 313) (cercla)
cadmium hydroxide
nickel (sara 313) (cercla)
nickel hydroxide (sara 313) (cercla)
potassium hydroxide (cercla)
===================== Product Identification =====================

MSDS NAME:CADNICA NICKEL CADMIUM BATTERY
NIIN:01-315-8599
MSDS Number: BXYGH
=== Responsible Party ===
Company:SANYO ENERGY USA CORP
Address:2001 SANYO AVE
City:SAN DIEGO
State:CA
ZIP:92173
Country:US
Info Phone Num:619-661-6620
Emergency Phone Num:NONE
CAGE:00JU0
=== Contractor Identification ===
Company:SANYO ENERGY(U.S.A.) CORP.
Address:2001 SANYO AVE
Box:City:SAN DIEGO
State:CA
ZIP:92173
Country:US
Phone:619-661-6620
CAGE:00JU0
Company:SKIL CORPORATION
Address:4300 WEST PATTERSON AVENUE
Box:City:CHICAGO
State:IL
ZIP:60646-5999
Country:US
Phone:312-286-7330
CAGE:55111

============= Composition/Information on Ingredients =============

Name:CADMIUM (SARA 313) (CERCLA)
CAS:7440-43-9
RTECS #:EU9800000
Fraction by Wt: 11-26%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG/M3 DUST; Z-2
ACGIH TLV:0.01 MG/M3 DUST;9495
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:CADMIUM HYDROXIDE
CAS:21041-95-2
Fraction by Wt: 11-26%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.05 MG CD/M3
ACGIH TLV:0.05 MG CD/M3

Name:NICKEL (SARA 313) (CERCLA)
CAS:7440-02-0
RTECS #:QR5950000
Fraction by Wt: 8-17%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9495

Name:NICKEL HYDROXIDE (SARA 313) (CERCLA)
CAS:12054-48-7
RTECS #:QR7040000
Fraction by Wt: 5-12%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG(NI)/M3
ACGIH TLV:0.1 MG(NI)/M3; 9495
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:POTASSIUM HYDROXIDE (CERCLA)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: <3%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

===================== Hazards Identification =====================

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: INHALATION OF CADMIUM DUSTS &
FUMES MAY CAUSE TOXIC SYSTEMIC EFFECTS. CONTACT WITH ELECTROLYTE
MAY CAUSE SKIN AND EYE BURNS/IRRITATION. INGESTION OF ELECTROLYTE
MAY CAUSE LOCALIZED BURNS; INGES TION OF CADMIUM CMDS MAY CAUSE
TOXIC SYSTEMIC EFFECTS. CHRONIC: PROLONGED EXPOSURE TO CADMIUM MAY
CAUSE CANCER, SEE SUPP
Explanation of Carcinogenicity:CONTAINS C [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:INHALED CADMIUM FUMES: DRY THROAT, RESPIRATORY
IRRITATION, HEADACHE, NAUSEA, VOMITING, CHEST PAIN, EXTREME
RESTLESSNESS, IRRITABILITY, PNEUMONITIS, BRONCHOPNEUMONIA.
SKIN-BURNS. EYES-SEVERE IRRITATION , BURNS. INGESTED-LOCALIZED
BURNS, INCREASED SALAVATION, CHOKING, NAUSEAA, PERSISTANT VOMITING,
DIARRHEA, ABDOMINAL PAIN
Medical Cond Aggravated by Exposure:A KNOWLEDGE OF AVAILABLE
TOXICOLOGICAL INFORMATION AND OF THE PHYSICAL AND CHEMICAL
PROPERTIES OF THE MATERIAL SUGGESTS THAT THE OVEREXPOSURE IS
UNLIKELY TO AGGRAVATE EXISTING MEDICAL CONDITIONS.

======================= First Aid Measures =======================

First Aid:INGESTED-DO NOT INDUCE VOMITING! SEEK IMMEDIATE MEICAL
ATTENTION. SKIN-IF CONTACT WITH ELECTROLYTE; FLUSH WITH WATER FOR
15 MINUTES. SEEK MEDICAL ATTENTION. INHALED-IF EXPOSED TO CADMIUM
DUST/FUMES; R EMOVE TO FRESH AIR AND SEEK MEDICAL ATTENTION.
EYES-IF ELECTROLYTE CONTACT; IMMEDIATELY FLUSH WITH LOTS OF WATER.
SEEK MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Extinguishing Media:ANY CLASS OF EXTINGUISHING MEDIUM MAY BE USED ON
THE BATTERIES OR THEIR PACKING MATERIAL.
Fire Fighting Procedures:EXPOSURE TO FIRE MAY CASUE RUPTURE OF CELLS;
POTENTIAL FOR EXPOSURE TO CADMIUM FUMES EXISTS.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

================== Accidental Release Measures ==================

Spill Release Procedures:SPILLS & LEAKS UNLIKELY BECAUSE CELLS ARE
CONTAINED IN AN HERMETICALLY SEALED CASE. IF BREACH OCCURS; DON
APPROPRIATE PERSONL PROTECTIVE CLOTHING AND ABSORB OR PACK SPILL
RESIDUES IN INERT MATERIAL.
Neutralizing Agent:DLA-HMIS: 5% ACETIC ACID.

====================== Handling and Storage ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM
INCOMPATIBLE MATERIALS. OPTIMUM STORAGE TEMPERATURES ARE BETWEEN
-31F AND 95F.
Other Precautions:THIS BATTERY IS DESIGNED FOR RECHARGING. A LOSS OF
VOLTAGE & CAPACITY OF BATTERIES DUE TO SELF-DISCHARGE DURING
PROLONGED STORAGE IS UNAVOIDABLE. CHARGE BATTERY BEFORE USE. DO NOT
INCINERATE OR SUBJEC T TO TEMPERATURES ABOVE 212F.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
CHRONIC HEALTH CONTINUED: REPEATED EXPOSURES TO CADMIUM MAY RESULT IN
LUNG, KIDNEY AND LIVER DISFUNCTION; SKELETAL DISEASE AND
REPRODUCTIVE TOXICITY. CHRONIC OVEREXPOSURE TO NICKEL MAY RESULT IN
CANCE R, DERMATITIS.

================== Physical/Chemical Properties ==================

HCC:Z5
Appearance and Odor:BATTERY ASSEMBLY; 12.0 VOLTS.

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
ELECTROLYTE: ACIDS, ALDEHYDES, CARBAMATE COMPOUNDS.
Stability Condition to Avoid:HEAT, OPEN FLAMES, SPARKS, AND MOISTURE.
Hazardous Decomposition Products:OXIDES OF CADMIUM AND NICKEL.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE OF IAW APPLICABLE LOCAL, STATE AND
FEDERAL REGULATIONS. RESULTANT SPILL RESIDUES MAY BE CHARACTERIZED
AS D002 (CASUTIC) AND D006 (CADMIUM) PURSUANT TO RCRA.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
NICAD STORAGE BATTERY
PHILLYBOND #6 HARDNER
32610-77-8
112-24-3
108-95-2
PHILLYBOND #6 RESIN
25068-38-6
OMEGA 2153A SN 313-3 75-09-2
67-56-1
108-88-3
S76 COMPRESSED RUBBER=BONDED ASBESTOS GASKET SHEET 12001-29-5
VARGLAS SILICONE RESIN 500
TURCOAT ALUMIGOLD 16871-71-9
1333-82-0
10043-35-3
ELECTRON VACUUM TUBE(S) 7440-33-7
321 DRY FILM LUBRICANT (AEROSOL) 7782-42-5
9022-96-2
1317-33-5
8052-41-3
68476-86-8
CAMCO QUIK STAIN & QUIK STAIN II
67-56-1
400009-342 PRY PASTE 144-62-7
PHENOLPHTHALEIN INDICATOR
7647-14-5
77-09-8
BROMCRESOL GREEN-METHYL RED
7447-40-7
MERCURIC OXIDE CELL 1310-58-3
21908-53-2
7439-97-6
7440-66-6
1313-13-9
BATTERY DRY BA-51/U (BA-3051/U) 7439-97-6
7646-85-7
12125-02-9
1313-13-9
1333-86-4
SPADNS REAGENT FOR FLUORIDE,444-11 7647-01-0
7784-46-5
7732-18-5
930-A LUBRIPLATE
11961,FORMALDEHYDE 50-00-0
67-56-1
7732-18-5
021931-000 NICKEL CADMIUM AIRCRAFT BATTERY 1313-99-1
1310-58-3
1306-19-0
7440-50-8
25587-80-8
SUPER QUADROLUBE 75W GEAR LUBRICANT 64742-53-6
64741-88-4
68649-42-3
SMC-772052 NICKEL CADMIUM SEALED CELL BATTERY 7440-43-9
21041-95-2
1306-19-0
7440-02-0
12054-48-7
1313-99-1
1310-58-3
7440-48-4
2018;2018T;LECTRA CLEAN AEROSOL 79-01-6
106-88-7
124-38-9
310 LIME 7439-89-6
7440-02-0
7439-96-5
7440-47-3
7782-41-4
471-34-1
7440-21-3
10006-28-7
P-755715-870 LIQUI-JET 2 DETERGENT 7732-18-5
64-02-8
1344-09-8
1310-58-3
BUFFER SOLUTION PH 7.0 (COLOR-CODED YELLOW),41138,SB-107-500 64-02-8
1310-73-2
7732-18-5
7778-77-0
68702,69702,68745,69704 SHELL DIALA(R) OIL AX 64742-46-7
64742-53-6
128-37-0
MOBIL SHC 634
PRY GEL 144-62-7
57-55-6
8006-54-0
2594 HEMA-CHEK CONTROL
2594 HEMA-CHEK SLIDE PAK
2594 HEMA-CHEK DEVELOPER 67-56-1
7722-84-1
1596 HEMA-CHEK DEVELOPER 67-56-1
7722-84-1
186 5013 KODAK CINEFLURE FIXER/REPLENISHER, PART A 7783-18-8
7732-18-5
127-09-3
10192-30-0
10043-35-3
64-19-7
7631-90-5
186 5013 KODAK CINEFLURE FIXER/REPLENISHER, PART B 7732-18-5
10043-01-3
7664-93-9
DL2032 LITHIUM MNO2 BATTERY 7439-93-2
1313-13-9
7440-44-0
108-32-7
110-71-4
7791-03-9
E-CR2032 ENERGIZER, LITHIUM-MANGANESE DIOXIDE BATTERY 1333-86-4
110-71-4
646-06-0
7439-93-2
7791-03-9
33454-82-9
1313-13-9
108-32-7
ISOVUE-M 200 60166-93-0
7732-18-5
77-86-1
62-33-9
7647-01-0
GASKET MATERIAL TYPE TBA 510 BLACK 12001-29-5
MIL-L-81352A COMP.L #36320
1330-20-7
13463-67-7
14807-96-6
110-43-0
78-93-3
BATTERY WET, FILLED WITH ACID, 8, UN2794, PGIII 7439-92-1
7664-93-9
7440-36-0
COMP A, MIL-P-23377, TY II, CL C 1330-20-7
100-41-4
64046-64-6
107-87-9
7789-06-2
64742-95-6
COMP B, MIL-P-2377, TY II, CL 2 68410-23-1
140-31-8
71-36-3
64742-95-6
1760-24-3
90-72-2
CYCLON SEALED LEAD BATTERY 7439-92-1
1309-60-0
7664-93-9
CADNICA NICKEL CADMIUM BATTERY 7440-43-9
21041-95-2
7440-02-0
12054-48-7
1310-58-3
F41-6931-000 CLC-500/550 TONER YELLOW 39382-25-7
72869-85-3
FREEZ-IT 2000, P/N ES1050, ES1250, ES1550 811-97-2
3:1, CAT, MIL-C-85285B, 36081, TYPE I 4035-89-6
28182-81-2
64742-95-6
64046-64-6
763-69-9
3:1, MIL-C-85285, 36081, TY I 64046-64-6
763-69-9
1330-20-7
100-41-4
108-88-3
26376-86-3
77-58-7
123-54-6
107-87-9
108-10-1
HARRIS HEMATOXYLIN (ACIDIFIED) 64-19-7
7784-26-1
7681-55-2
HARRIS HEMATOXYLIN CYTOLOGY/HISTOLOGY STAIN 7732-18-5
10043-67-1
64-17-5
64-19-7
21908-53-2

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net