===================== Product Identification =====================
MSDS NAME:SPEED ENAMEL, 17875
NIIN:00N066410
MSDS Number: CBDPD
=== Responsible Party ===
Company:MAJOR PAINT CO
Address:4300 WEST 190TH STREET
City:TORRANCE
State:CA
ZIP:90509-2868
Country:US
Info Phone Num:213-542-7701
Emergency Phone Num:213-542-7701
CAGE:0V1C9
=== Contractor Identification ===
Company:MAJOR PAINT CO
Address:4300 W 190TH ST
Box:City:TORRANCE
State:CA
ZIP:90509-2868
Country:US
Phone:310-542-7701
CAGE:0V1C9
============= Composition/Information on Ingredients =============
Name:VM & P NAPHTHA;(ALIPHATIC PETROLEUM DISTILLATE). BP:
240-285F. VP: 15 @ 100F.
CAS:64742-89-8
OSHA PEL:100 PPM(MFR)
ACGIH TLV:300 PPM(MFR)
Name:TOLUENE (SARA 313) (CERCLA). VP: 22.0 @ 68F.
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 6%
OSHA PEL:200 PPM; Z-2
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:SOLVENT NAPHTHA;(AROMATIC PETROLEUM DISTILLATE). BP: >350F.
VP: 5.2 @ 100F.
CAS:64742-94-5
RTECS #:WF3100000
OSHA PEL:N/K
ACGIH TLV:N/K
Name:METHANE,DICHLORO-; (METHYLENE CHLORIDE). VP: 420 @ 77F.
(SARA 313) (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 48%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:500 PPM; Z-2
ACGIH TLV:50 PPM, A2; 9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:PROPANE. VP: 200.0 @ 100F.
CAS:74-98-6
RTECS #:TX2275000
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT
Name:PROPANE, 2-METHYL-; (ISOBUTANE). VP: 72.0 @ 100F.
CAS:75-28-5
RTECS #:TZ4300000
OSHA PEL:1000 PPM(MFR)
ACGIH TLV:1000 PPM(MFR)
Name:OTHER PRECS: PROD MAY BE HARMFUL/FATAL. DO NOT SAND, FLAME
CUT, BRAZE/WELD DRY COATING W/OUT NIOSH/MSHA APPRVD (ING 8)
RTECS #:9999999ZZ
Name:ING 7: RESP OR SUFFICIENT VENTILATION. NO SMOKING IN AREA
OF USE. DO NOT USE IN THE GENL VICINITY OF ARC(ING 9)
RTECS #:9999999ZZ
Name:ING 8: WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/UV
RADIATION MAY CAUSE FORMATION OF HCL &/PHOSGENE .
RTECS #:9999999ZZ
Name:OTHER PROT EQUIP: SPILL, SPLASH OR EXCESS OVERSPRAY. DO NOT
USE CLTHG/SHOES WHILE SOLV ODOR IS RETAINED IN THEM.
RTECS #:9999999ZZ
Name:EFTS OF OVEREXP: ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN (ING 12)
RTECS #:9999999ZZ
Name:ING 11: HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS.
RTECS #:9999999ZZ
Name:FIRST AID PROC:NORMAL REQUIRED. IF BREATHING DFCLTYS
DEVELOP SEEK MED HELP. INGEST: CALL MD IMMEDIATELY.
RTECS #:9999999ZZ
Name:EXPLAN OF CARCIN: ANTICIPATED TO BE CARCINOGEN. ANIMAL:
LUNG, LIVER, SALIVARY, MAMMARY GLAND(TUMORS).
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE:MATL MAY CAUSE EYE IRRIT.
DIRECT CONT W/LIQ/EXPOS TO AEROSOLS MAY CAUSE BURN, TEAR & REDNESS.
SKIN(ABSORP):MATL IS NOT KNOWN TO BE SKIN IRRIT, HOWEVER, IF
ALLOWED TO REMAIN ON SKIN W/OUT BEIN G RINSED OFF W/WATER, A THIN
FILM MAY FORM. REMOVAL OF FILM MAY RSLT IN SLIGHT IRRIT DEPENDENT
ON METH(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONO, SUPP, VOL
7, PG 194, 1987: GROUP 2B. NTP 7TH ANNUAL REPORT ON CARCINS, 1994:
ANTIC(ING 14)
Effects of Overexposure:HLTH HAZ:OF REMOVAL. TOLUENE APPEARS ON NAVY
LIST OF OCCUP CHEM REPRO HAZS. SEEK CONSULT FROM APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
INFO. CHLOROCARBON MA TLS HAVE PRDCED SENSIT OF MYOCARDIUM
TOEPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS.
(ING 11)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE: IF IRRIT/REDNESS FROM EXPOS TO VAPS DEVELS, MOVE VICTIM
AWAY FROM EXPOS & INTO FRESH AIR. IF IRRIT/REDNESS PERSISTS, SEEK
MED HELP. HOLD EYELIDS APART & FLUSH AFFECTED EYE W/CLEAN WATER FOR
AT LE AST 15 MIN. SEEK MED HELP. SKIN: REMOVECONTAMD CLTHG. CLEANSE
AFFECTED AREA THORO BY WASHING W/MILD SOAP & WATER. IF
IRRIT/REDNESS DEVELS & PERSISTS, SEEK MED HELP. INHAL: FIRST AID IS
NOT(ING 13)
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:<20F,<-7C
Lower Limits:1.0%
Upper Limits:25.0%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP. AVOID CONFINED SPACES. WATER MAY BE UNSUITABLE AS
AN EXTINGUISHING MEDIA.
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY ACCUM IN LOW AREAS
OF POOR VENT/TRAVEL ALONG GROUND TO REMOTE IGNIT SITES. CONTENTS
ARE UNDER PRESS. KEEP COOL, EXPOS TO HEAT(SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:EVAC AREA. REMOVE SOURCES OF IGNIT, INCLG HOT
METAL SURFS. WEAR APPROP CLTHG & GEAR. PVNT CONT & AVOID BRTHG OF
VAPOR. CONFINE IMMED & REMOVE W/INERT ABSORBANT SUCH AS CLAY OR
SAND.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:OBSERVE LABEL PRECS. KEEP AWAY FROM
HEAT, SPARKS & OPEN FLAME (I.E., ALL IGNIT SOURCES). CAP CNTNR FOR
EACH USE. DO NOT STORE >120F.
Other Precautions:STORE IN DRY, WELL VENTED PLACE. DO NOT EXPOSE TO
DIRECT SUNLIGHT TO AVOID BURSTING. DO NOT SPRAY NEAR FIRE/FLAME.
AVOID UNNEC CONT. DO NOT TAKE INTERNALLY. DO NOT PUNCTURE CNTNRS.
INTENTIONAL MISUSE BY DELIB CONC & INHALING VAPS OF(ING 7)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DO NOT BRTHG VAPS/MISTS. IF TLV,PEL/OTHER LIMS
ARE EXCEEDED THEN WEAR PROPERLY FITTED VAP & PARTICULATE/POS PRESS
AIR SUPPPLIED RESP APPRVD BY NIOSH/MSHA FOR USE W/PAINTS DURING
APPLIC UNTIL ALL VAPS & SPRAY MISTS EXHST. FOLLOW(SUPDAT)
Ventilation:PROVIDE SUFF VENT IN VOL & PATTERN TO KEEP CONTAM -43F,>-42C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:0.9(H*20=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:AEROSOL CAN.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NO HAZARDOUS REACTIONS ARE EXPECTED TO OCCUR UNDER NORMAL INDUSTRIAL
CONDITIONS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:COMBUSTION MAY YIELD CARBON MONOXIDE
&/CARBON DIOXIDE. HCL, PHOSGENE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ALLOW TO CONTAM GROUND WATER SYSTEMS.
PLACE IN NON-LEAKING CNTNRS. DISPOSE OF ABSORBED MATL IN ACCORDANCE
W/LOCAL, STATE & FEDERAL REGULATIONS. DO NOT INCINERATE IN CLOSED
CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|