===================== Product Identification =====================
MSDS NAME:STAMFORD A-1 ALUMINUM PASTE
NIIN:00N071325
MSDS Number: CDZPV
=== Responsible Party ===
Company:SILBERLINE MFG CO INC
Box:B
City:TAMAQUA
State:PA
ZIP:18252
Country:US
Info Phone Num:717-668-6050
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:0U0T3
=== Contractor Identification ===
Company:SILBERLINE MFG CO INC
Address:LINCOLN DR
Box:B
City:TAMAQUA
State:PA
ZIP:18252
Country:US
Phone:570-668-6050
CAGE:0U0T3
============= Composition/Information on Ingredients =============
Name:ALUMINUM; (ALUMINUM FLAKE) (SARA 313)
CAS:7429-90-5
RTECS #:BD0330000
Fraction by Wt: 60-80%
OSHA PEL:15 MG/M3 DUST
ACGIH TLV:10 MG/M3 DUST
Name:STODDARD SOLVENT. VP:<10 @ 77F. VAP DENS:4.8. EVAP
RATE:<0.1 (N-BUTYL ACETATE=1). LEL:0.9%. UEL:7%. (ING 3)
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 20-40%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM
Name:ING 2:LD50:(ORAL,RAT) >5000 MG/KG.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPP DATA:AGENTS LIKE HALON OR CARBON TETRACHLORIDE.
RTECS #:9999999ZZ
Name:FIRE FIGHT PROC:IN RUPTURE OF CNTNR. USE WATER FOG TO KEEP
FIRE-EXPOS CNTNRS COOL. DENSE SMOKE MAY BE GENERATED (ING 6)
RTECS #:9999999ZZ
Name:ING 5:WHILE BURNING. MIN BRTHG GASES, VAPS, FUMES/DECOMP
PRODS DURING FIRE. ALUMINUM FIRE MAY REACT W/WATER TO (ING 7)
RTECS #:9999999ZZ
Name:ING 6:FORM HYDROGEN GAS. HYDROGEN GAS IS FLAMMABLE &
EXPLOSIVE.
RTECS #:9999999ZZ
Name:EXPLO HAZ:STREAMS/GAS PROPELLED FIRE EXTINGS INTO BURNING
MATL. DIRECT CLASS B EXTING AGENT ABOVE FIRE TO RAIN (ING 9)
RTECS #:9999999ZZ
Name:ING 8:DOWN ON BURNING MATL. CARE SHOULD BE USED WHEN
APPLYING CLASS B EXTING AGENT BECAUSE SOME AGENTS CAN ACCEL(ING 10)
RTECS #:9999999ZZ
Name:ING 9:FIRE WHERE MOST OF SOLV IN PASTE HAS BEEN CONSUMED &
ALUMINUM FLAKE HAS STARTED TO BURN. IF EXTING AGENT (ING 11)
RTECS #:9999999ZZ
Name:ING 10:IS CAREFULLY APPLIED, IT WILL BE VERY EVID IF IT
ACCELS FIRE. IF IT DOES/IF FIRE AT SOME POINT HAS APPEAR(ING 12)
RTECS #:9999999ZZ
Name:ING 11:OF METAL BURNING W/BRIGHT, WHITISH GLOW, DO NOT
ATTEMPT TO EXTING IT. ISOLATE FIRE BY RINGING IT W/DRY, (ING 13)
RTECS #:9999999ZZ
Name:ING 12:INERT GRANULAR MATL/CLASS D EXTING AGENT, THEN LET
IT ALONE. ALLOW MATL TO BECOME COLD PRIOR TO DISP, (ING 14)
RTECS #:9999999ZZ
Name:ING 13:BECAUSE IF METAL HAS IGNITED, IT MAY CONTINUE TO
BURN UNDER CRUST W/OUT FLAMES. FOR FURTHER INFO, SEE (ING 15)
RTECS #:9999999ZZ
Name:ING 14:NFPA-651, STANDARD FOR THE MANUFACTURE OF ALUMINUM &
MAGNESIUM POWDER.
RTECS #:9999999ZZ
Name:FIRST AID PROC:RESUSCITATION, ADMIN OXYG IF AVAIL. GET MED
HELP AS SITUATION DICTATES. INGEST:DO NOT INDUCE (ING 17)
RTECS #:9999999ZZ
Name:ING 16:VOMITING. CALL MD OR GET TO PROFESSIONAL MEDICAL
HELP IMMEDIATELY.
RTECS #:9999999ZZ
Name:WASTE DISP METH:NOT USE CUTTING TORCH ON, & DO NOT WELD ON,
EMPTY METAL CNTNRS. EMPTY DRUMS SHOULD BE CRUSHED (ING 19)
RTECS #:9999999ZZ
Name:ING 18:&/OR RECYCLED/BE DISPOSED OF BY PERMITTED WASTE
DISPOSAL COMPANY I/A/W ALL APPLIC FEDERAL, STATE & LOCAL LAWS.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENT 2.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MAY CAUSE IRRIT.
SKIN:PRLNG/RPTD CONT TENDS TO REMOVE OILS POSS CAUSING IRRIT &
DERM. HUMAN SKIN PATCH TEST SHOWED IRRIT & PHOTOSENSIT EFT.
INHAL:HIGH SOLV VAP CONCS ARE IRRIT TO RESP TRACT. MAY CAUSE DIZZ
& HDCHS, ARE ANESTH & MAY HAVE OTHER CNS EFTS. INGEST:DO NOT
INGEST. SLIGHTLY TOX. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HOWEVER, MIN AMTS OF SOLV ASPIR INTO
LUNGS IF INGESTED MAY CAUSE SEV PULM INJURY/DEATH. CHRONIC:PRLNG &
RPTD INHAL EXPOS CAN PRDCE ADVERSE KIDNEY EFTS IN MALE RATS. IT IS
HIGHLY UNLIKELY THAT KIDNEY EFTS HAVE SIGNIFICANT IMPLICATIONS FOR
HUMANS EXPOS AT/BELOW REC VAP LIMS IN WORKPLACE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:FLUSH W/PLENTY OF LOW PRESS WATER FOR AT LST 15 MINS,
OCCAS LIFTING LIDS. IF IRRIT PERSISTS, CONSULT MD. SKIN:REMOVE
CONTAM CLTHG & LAUNDER BEFORE REUSING. DO NOT REUSE LEATHER &
ABSORB SHOES. WA SH W/MILD SOAP & WATER & APPLY GOOD QUALITY HAND
CREAM. IF IRRIT PERSISTS, CONSULT MD. INHAL:REMOVE TO FRESH AIR. IF
UNCON, KEEP BRTHG PASSAGE OPEN. IF BRTHG IS IRREG/HAS STOPPED,
START (ING 16)
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:>100F,>38C
Lower Limits:SEE ING 2
Upper Limits:SEE ING 2
Extinguishing Media:USE CLASS B EXTING, INERT GRANULAR MATL LIKE DRY
SAND, CLASS D EXT W/LOW VELOCITY NOZZ, CLASS D EXTING AGENT,(SUPP
DATA)
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . WHEN
CLSD CNTNRS ARE EXPOS TO EXCESS HEAT, THERE IS POSS OF PRESS
BUILDUP INSIDE CNTNR. THIS COULD RSLT (ING 5)
Unusual Fire/Explosion Hazard:COMBUST LIQ-CLASS II. ALUMINUM PARTICLES
SUSPENDED IN AIR MAY FORM EXPLO MIXT; AVOID ANY DISTURB WHICH COULD
CAUSE DUST CLOUD, SUCH AS DIRECTING WATER (ING 8)
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID EXPOS TO VAPS. WEAR PROPER PPE. REMOVE
ALL SPKS, FLAMES & OTHER SOURCES OF IGNIT FROM AREA & ALLOW ANY HOT
SURFS IN AREA TO COOL. USE NONSPARKING METAL TOOLS & NATRL BRISTLE
BROOM. REPACK UNCONT AM PASTE IN DRY CNTNR. SEAL CNTNR
TIGHTLY.(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE/USE IN AREAS OF EXCESS
WATER VAP, CONTAM VAPS/GASES. DO NOT STORE NEAR OXIDIZERS/COMBUST
MATLS. KEEP CNTNRS CLSD WHEN NOT IN USE.
Other Precautions:AVOID SPILLAGE & CREATION OF AIRBORNE ALUMINUM DUST.
USE NONSPARKING METAL TOOLS TO TRANSFER. ALL EQUIP SHOULD BE ELEC
GROUNDED. MIN BRTHG OF VAPS. AVOID PRLNG/RPTD SKIN CONT. VEHICLES
IN AREA SHOULD HAVE NONSPARKING WHEELS. WHERE (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF VAP &/OR DUST CONCS ARE AT/ABOVE ALLOWABLE
EXPOS LIM, WEAR NIOSH APPRVD AIR PURIFYING (CHEM CARTRIDGE) RESP
SUITABLE FOR ORG VAPS &/OR PARTICULATES. IN CONFINED SPACES/WHERE
VAP CONCS COULD EXCEED 1000 PPM, USE NIOSH APPRVD (SUPP DATA)
Ventilation:USE GENERAL DILUTION TYPE, ADEQUATE TO KEEP VAPOR
CONCENTRATIONS BELOW THE TLV'S OR LEL LISTED.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . USE CHEMICAL RESISTANT APRON & PROTECTIVE HAND CREAMS.
Work Hygienic Practices:WASH UP W/SOAP & WATER BEFORE EATING, DRINKING,
SMOKING/USING TOILET FACILITIES. LAUNDER CONTAM CLTHG BEFORE REUSE.
Supplemental Safety and Health
HAZ DECOMP PROD:FORM HYDROGEN GAS & HEAT. SPILL PROC:CHECK FOR QUALITY.
DISP OF CONTAM MATL/WASTE. OTHER PREC:APPROP, INSTALL ELEC EQUIP
SUITABLE FOR USE IN HAZ ATMS I/A/W NEC. RESP PROT:SUPPLIED-AIR
RESP/SCBA W/FULL FACE-PIECE. EXTING MEDIA:REGULAR PROTEIN
FOAM/AFFF. DO NOT USE WATER HOSE STREAM/HALOGENATED (ING 4)
================== Physical/Chemical Properties ==================
Vapor Pres:SEE ING 2
Vapor Density:SEE ING 2
Spec Gravity:1.38-1.81
Evaporation Rate & Reference:SEE INGREDIENT 2
Appearance and Odor:SILVER SEMISOLID; AROMATIC HYDROCARBON ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
SOME ACIDS, SOME CAUSTICS, WATER, HALOGENATED HYDROCARBONS & OXIDIZERS.
Stability Condition to Avoid:SMOKING, OPEN FLAMES, AIR, SPARKS & OTHER
SOURCES OF IGNITION & HEAT.
Hazardous Decomposition Products:SMOKE, CARBON MONOXIDE, CARBON DIOXIDE
& ALUMINUM OXIDE. ALUMINUM FLAKE CAN REACT W/SOME ACID & CAUSTIC
SOLNS TO(SUPDAT)
==================== Disposal Considerations ====================
Waste Disposal Methods:HAZ WASTE AS DEFINED IN 40 CFR 261 W/HAZ WASTE
#D001. SHOULD BE TRANSPORTED & DISP OF BY PERMITTED HAZ WASTE
TRANSPORTATION & DISP COMPANY I/A/W ALL APPLIC FED, STATE & LOC
LAWS. EMPTY CNTNRS CNTN RES IDUE OF PASTE & SHOULD NOT BE REUSED.
DO (ING 18)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|