===================== Product Identification =====================
MSDS NAME:RHODORSIL FLUID 47V20
NIIN:00-487-4219
MSDS Number: CFKRD
=== Responsible Party ===
Company:NORTH AMERICAN CHEMICALS ZONE, RHONE-POULENC
Address:CN7500
City:CRANBURY
State:NJ
ZIP:08512-7500
Country:US
Info Phone Num:609-860-4000
Emergency Phone Num:800-424-9300(CHEMTREC)/800-334-7577
CAGE:41629
=== Contractor Identification ===
Company:NORTH AMERICAN CARBON INC.
Address:ELK RUN AVE
Box:436
City:PUNXSUTAWNEY
State:PA
ZIP:15767
Country:US
Phone:814-938-7450
CAGE:41629
Company:RHONE-POULENC INC
Box:125
City:MONMOUTH JUNCTION
State:NJ
ZIP:08852-0125
Country:US
Phone:800-334-7577
CAGE:7B998
Company:THE SMITH GROUP INC.
Address:811 E. CAYUGA STREET
Box:City:PHILADELPHIA
State:PA
ZIP:19124-3893
Country:US
Phone:215-743-8200
CAGE:2B613
============= Composition/Information on Ingredients =============
Name:POLY (DIMETHYLSILOXANE)
CAS:63148-62-9
RTECS #:JJ6484500
Fraction by Wt: NP
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 RATS,ORAL >5004MGKG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:SLIGHTLY IRRIT,MAY CAUSE
REDNESS,IRRIT.SKIN:NON-RIRIT.INHAL:NOT LIKELY.INGEST:PRACTICALLY
NON-TOXIC.CHRONIC:DOESNT CONTAN ANY INGRED DESIGNATED BY
IARC/NTP/ACGIH/OSHA AS PROBABLE/SUSPECTED HUMAN C ARCINOGENS.
Explanation of Carcinogenicity:PER MSDS:DOESNT CONTAIN ANY INGRED
DESIGNATED BY IARC/NTP/ACGIH/OSHA AS PROBABLE/SUSPECTED HUMAN
CARCINOGENS.
Effects of Overexposure:IRRIT EYE, REDNESS.
Medical Cond Aggravated by Exposure:NO SPECIFIC INFORMATION FOUND.
======================= First Aid Measures =======================
First Aid:EYE:IMMED ABSORB EXCESS W/CLEAN ABSORBENT CLOTH/COTTON.OPEN
EYELIDS,FLUSH W/STEADY GENTLY H2O STREAM FOR @LEAST 15MINS.IRRIT
DVLP/PERSIST/VISUAL CHANGES OCCUR SEEK MED ATTN.SKIN:IMMED WIPE
EXCESS W/DR Y CLOTH.WASH W/PLENTY OF SOAP/H2O.IRRITDVLP/PERSIST
SEEK MED ATTN.INHAL:NOT EXPECTED ROUTE OF EXPO.RESP IRRIT/DISTRESS
OCCUR REMOVE TO FRESH AIR;CONTS SEEK MED ATTN.INGEST:CONS/ALERT
GIVE 1-2(SUPPLE)
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>446F,>230C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NO DATA
Upper Limits:NO DATA
Extinguishing Media:RECOMMENDED:DRY CHEMICAL, FOAM, CARBON DIOXIDE.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING APPARATUS & FULL PROTECTIVE CLOTHING.COOL
CNTNR EXPO TO FIRE W/WATER.
Unusual Fire/Explosion Hazard:PRODUCT WILL BURN UNDER FIRE CONDITIONS.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR APPROPR PROT GEAR FOR SITUATION.SEE PPE
SECTION.CAUTION:SPILLED MATL MAY MAKE FLOOR SLIPPERY.DONT LEAVE
TRACES OF PRODUCT ON FLOORS/LADDERS/ETC AS THIS MAY PRESENT
SLIPPING HAZ.ABSORB W/INERT ABS ORBENT.SCRAPEUP/PLACE IN CLSD
CNTNR.CLEANUP(NEUTR)
Neutralizing Agent:SPILL:W/APPROPR SOLVT(PAINT THINNER/MINERAL
SPIRITS)-GOOD VENTI/NO IGN SOURCES.
====================== Handling and Storage ======================
Handling and Storage Precautions:>25C(77F) STORAGE TEMPS.AVOID VAP/MIST
BREATH.AVOID DIRECT/PROL CONTACT W/SKIN/EYES.USE NONSPARK
TOOLS/GROUND/BOND EQPMT/CNTNR WHEN TRANSFERRING.
Other Precautions:CONTAINS DIMETHYLPOLYSILOXANE CAN GENERATE
FORMALDEHYDE AS BYPRODUCT OF OXIDATIVE THERM DECOMPO BEGINNING
@APPROX 150C(300F).FORMALDEHYDE EXPO-CAUSE ADVERSE
EFFECTS-SKIN/RESP SENS,EYE/THROAT IRRIT,POT CANC
HAZ.EVALUATE/CNTRL EXPO(SUP)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN RESP REQUIRED SELECT NIOSH/MSHA APPROV
EQPMT BASED ON ACTUAL/POT AIRBORNE CONC & IAW APPROP REG STD &/OR
INDUSTRIAL RECOMMENDATIONS.FOR REASONABLY FORESEEABLE INDUSTRIAL
END USEDS OF MATL RESP PR OT SHOULDNT BE NECESSARY.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:ANSI Z87
Eye Protection:ANSI Z87,MIN SAF GLASSES W/SIDESHIELD
Other Protective Equipment:GLOVES,SUITABLE LONG-SLEEVED
CLOTH(SHIRTS,PANTS).CONSIDER DURABILITY/PERMEATION RESISTANCE.
Work Hygienic Practices:GOOD INDUSTRIAL HYG PRAC SHOULD BE USED IN
HNDLG MATL.STORE IN TIGHT CLSD CNTNR-EPOXY-COAT
STEEL,PLAS,POLYETHYLENE.
Supplemental Safety and Health
OTHER PRECA:TO FORMALDEHYDE WHEN WARRANTED BY USE CONDITIONS.
1STAID:GLASSES OF H2O TO DRINK.DONT GIVE ANYTHING BY MOUTH IF
UNCONSC.GET MED ATTN.DONT LEAVE UNATTN.DR:ALL TREAT SHOULD BE BAESD
ON OBSER VE SIGNS/SYMPT OF DISTRSS IN PATIENT.CONSIDERATION SHOULD
BE GIVEN TO POSSIBLITY MATL OVEREXPO OTHER THAN PROD MAY OCCUR
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:B.P. Text:N/AVAI
Melt/Freeze Pt:M.P/F.P Text:N/AVAI
Decomp Temp:Decomp Text:NP
Vapor Pres:<0.01@200C
Vapor Density:N/AVAI
Spec Gravity:0.95 @25C
pH:N/APPL
Viscosity:20CS @25C
Evaporation Rate & Reference:NP
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR VISCOUS LIQUID, ODORLESS
Percent Volatiles by Volume:NP
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG BASES,STRONG ACIDS,STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT,OPEN FLAME,SPARK,STATIC ELECTRICITY
Hazardous Decomposition Products:FORMALDEHYDE,OXIDES OF
CARBON,SILICA(CRYSTALLINE).THERM-DIMETHYLCYCLOSILOXANES,METHYLPHENY
LCYCLOSILOXANES;OXI/THER-FORMA
==================== Disposal Considerations ====================
Waste Disposal Methods:DONT FLUSH SPILL TO DRAIN.CHEM
ADDN/PROCESS/OTHERWISE ALTER MATL MAY MAKE WSTE MNGMT INFO IN MSDS
INCOMPL/INACCU/INAPPRO.BE ADVISED STATE/LOC REQMTS FOR WSTE DISPO
MAY BE MORE RESTRICTIVE/DIFF FROM FE D LAW/REG.CONSULT STATE/LOC
REGS.EMPTY-DECONTAM
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|