===================== Product Identification =====================
MSDS NAME:SOLUTION S0801 FIXING SLN (10% NITRIC ACID SOLUTION)
NIIN:00-237-2918
MSDS Number: CFKQQ
=== Responsible Party ===
Company:NALCO CHEMICAL COMANY
Address:ONE NALCO CENTER
City:NAPERVILLE
State:IL
ZIP:60563-1198
Country:US
Info Phone Num:630-305-1000
Emergency Phone Num:630-920-1510/800-I-M-ALERT/462-5372
Preparer's Name:WILLIAM S. UTLEY,PHD
CAGE:89524
=== Contractor Identification ===
Company:NALCO CHEMICAL CO
Box:UNKNOW
CAGE:004N2
Company:NALFLEET INC
Address:195 MOUNTAIN AVE
Box:City:SPRINGFIELD
State:NJ
ZIP:07081-1755
Country:US
Phone:973-379 -1340
CAGE:95719
Company:ONDEO NALCO COMPANY
Address:ONDEO NALCO CENTER
Box:City:NAPERVILLE
State:IL
ZIP:60563-1198
Country:US
Phone:(630) 305-1000
CAGE:89524
============= Composition/Information on Ingredients =============
Name:NITRIC ACID (SARA 302/313) (CERCLA)
CAS:7697-37-2
RTECS #:QU5775000
Fraction by Wt: 10%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:2 PPM
ACGIH TLV:2 PPM/4 STEL; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DANGER!CAUSES BURNS TO
SKIN/EYES.EYE:CORRO TO EYE W/POSSIBLE PERM DMG DEPENDING ON LENGTH
OF EXPO & 1STAID ACTION GIVEN.SKIN:CORRO TO SKIN POSSIBLY RESULTING
IN 3RD DEGREE BURNS DEPENDING ON LENGTH OF EXPO & 1STAID ACTION
GIVEN.CAN BE HARMFUL IF ABSORBED.CAN CAUSE ALLERGIC CONTACT DERM IN
SUSCEPTIBLE PEOPLE.(SUPPLEMEN)
Effects of Overexposure:A REVIEW OF AVAILABLE DATA DOES NOT IDENTIFY
ANY SYMPTOMS FROM EXPOSURE NOT PREVIOUSLY MENTIONED.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIY ANY WORSENING OF EXISTING CONDITIONS.
======================= First Aid Measures =======================
First Aid:EYE:IMMED FLUSH FOR @LEAST 15MINS WHILE HOLDING EYELIDS
OPEN.CALL DR @ONCE.SKIN:IMMED FLUSH W/WATWER FOR @LEAST 15MIONS.FOR
LG SPLASH FLOOD BODY UNDER SHOWER.CALL DR @ONCE.INGEST:DONT INDUCE
VOMIT.GIV E WATER.CALL DR.INHAL:REMOVE TO FRESH AIR.TREAT
SYMPTOMS.CALL DR.DR:BASED ON INDIVIDUAL REACTIONS OF PATIENT DR'S
JUDGMENT SHOULD BE USED TO CONTROL SYMPT/CLINC
CONDITION.UNFONC/TROUBLE BREATH (SUPPL)
===================== Fire Fighting Measures =====================
Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:CONTACT W/REACTIVE
METALS(E.G.ALUMINUM)MAY RESULT IN GENERATION OF FLAMMABLE HYDROGEN
GAS.
================== Accidental Release Measures ==================
Spill Release Procedures:TRANSPO ACCIDENTS CALL 800-462-5378.SM:COVER
SURF W/SODIUM BICARBONATE OR SODA ASH-SLAKE LIME MIX.MIX/ADD H2O IF
NECESSARY FOR SLURRY.SCOOP UP SLURRY.WASH DOWN DRAIN W/EXCESS H2O.
Neutralizing Agent:SODIUM BICARBONATE OR SODA ASH-SLAKE LIME MIXTURE.
====================== Handling and Storage ======================
Handling and Storage Precautions:EMPTY CNTNR SHOULD BE PUNCTURE IF
PLASTIC,PLACE IN GARBAGE COLLECTION CNTNR.HNO3 RQ-10000LBS RELEASE
REQUIRES NAT RES CNTR NOTIFICA 800-424-8802.SARA.
Other Precautions:KEEP CNTNR CLSD WHEN NOT IN USE.DONT GET IN
EYE/SKIN/CLOTH.AVOID BREATH VAP.USE W/ADEQU VENTI.DONT TAKE
INTERNALLY.EMTPY CNTNR MAY CONTAIN RESIDUEL PROD.DONT REUSE CNTNR
UNLESS PROPERLY RECONDITION.TP Q=1000LBS SEC 302.NOT CLEAN AIR ACT
MATL
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF ITS POSSIBLE TO GENERATE SIGNIFICANT LEVELS
OR VAPORS OR MISTS NIOSH APPROVED OR ACID RESPIRATOR IS
RECOMMENDED.
Ventilation:GENERAL VENTI IS RECOMMENDED.ADDN LOCAL EXHAUST VENTI
RECOMMENDED WHERE VAPORS MAY BE RELEASED.
Protective Gloves:WEAR GLOVES
Eye Protection:GOGGLES,FACE SHIELD,CHEM SPLASH GOGG
Other Protective Equipment:WEAR APRON.AVAILABILITY OF EYE WASH FOUNTAIN
& SAF SHOWER RECOMMENDED.
Work Hygienic Practices:CLOTH CONTAM REMOVE & THOROUGHLY WASH AFFECTED
AREA.LAUNDER CONTAM CLOTH BEF REUSE.
Supplemental Safety and Health
HEALTH:INGEST:CAN BE HARMFUL.INHAL:CAN BE CORRO TO MUCOUS MEMB & LUNGS.
1STAID:&CONVULSIONS DONT INDUCE VOMIT OR GIVE H2O.PROBABLE MUC DMG
MAY CONTRAINDICATE USE OF GASTRIC LAVAGE.MEASURES AGAINST CIR
CULATORY SHOCK,RESP DEPRESS,CONVUL MAY BE NEEDED. INCOMPAT:GENERATE
HEAT W/SPLATTER/BOIL/RELEASE OF TOXIC FUMES.
================== Physical/Chemical Properties ==================
HCC:C1
Boiling Pt:B.P. Text:NP
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:NP
Vapor Density:NP
Spec Gravity:NP
pH:<1
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:COMPLETELY
Appearance and Odor:COLORLESS, LIQUID, ACRID ODOR
Percent Volatiles by Volume:NP
Corrosion Rate:NP
================= Stability and Reactivity Data =================
ALKALINE
MATLS(AMMONIA/SOLNS,CARBONATES,NAOH(CAAUSTIC),KOH,CA(OH)2(LIME),CYA
NIDES,SULFIDES,HYPOCHLORITES,CHLORITES)(SUP)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EVENT OF COMBUSTION CO2,NOX MAY BE
FORMED.DONT BREATH SMOKE.FUMES.WEAR SUITABLE PROTECTIVE EQPMT.
==================== Disposal Considerations ====================
Waste Disposal Methods:RELEASED INTO ENVIRO SEE CERCLA.PRODUCT BECOJES
WASTE MEETS CRITERIA OF HAZ WASTE PER RCRA-D002.ACID SOLNS SHOULD
BE NEUTRALI BEF DISCHARGE TO SANITARY SEWER.ALTERN MAY BE DISPO
INTO WASTE TREAT PLANT WHICH HAS PH CNTRL SYS IN
OPERATION.(HNDL/STORAG)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|