===================== Product Identification =====================
MSDS NAME:STA-CLEAN RCP
NIIN:00-139-5319
MSDS Number: CFKQF
=== Responsible Party ===
Company:STA-CLEAN PRODUCTS INC
Address:2229 COY AVE
City:BAKERSFIELD (FORMALLY IN DOWNEY, CA)
State:CA
ZIP:93307
Country:US
Info Phone Num:805-835-8652
Emergency Phone Num:661-836-8652
Resp. Party Other MSDS Num.:#STA330R VERSION 002
Preparer's Name:NOT PROVIDED
Chemtrec Ind/Phone:(800)424-9300
CAGE:21172
=== Contractor Identification ===
Company:STA-CLEAN PRODUCTS INC
Address:2229 COY AVENUE
Box:City:BAKERSFIELD
State:CA
ZIP:93307
Phone:(805) 836-8652
Contract Num:SP0450-00-M-SG54
CAGE:21172
Company:STA-CLEAN PRODUCTS INC
Address:2229 COY AVENUE
Box:City:BAKERSFIELD
State:CA
ZIP:93307
Phone:(805) 836-8652
Contract Num:SP0450-99-M-NH60
CAGE:21172
============= Composition/Information on Ingredients =============
Name:ALIPHATIC PETROLEUM DISTILLATE
CAS:64742-52-5
= Wt:80.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NOT PROVIDED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: OF MIST CAN CAUSE
IRRITATION OF NASAL AND RESPIRATORY PASSAGES. EYE CONTACT: MAY
CAUSE MINOR EYE IRRITATION. SKIN: MAY CAUSE MINOR IRRITATION.
INGESTION: CAN CAUSE GASTROINTESTINAL IRRITAT ION, NAUSEA,
VOMITING, AND DIARRHEA. ASPIRATION OF MATERIAL INTO THE LUNGS CAN
CAUSE CHEMICAL PNEUMONITIS WHICH MAY BE FATAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: OF MIST CAN CAUSE IRRITATION OF
NASAL AND RESPIRATORY PASSAGES. EYE CONTACT: MAY CAUSE MINOR EYE
IRRITATION. SKIN: MAY CAUSE MINOR IRRITATION. INGESTION: CAN CAUSE
GASTROINTESTINAL IRRITAT ION, NAUSEA, VOMITING, AND DIARRHEA.
Medical Cond Aggravated by Exposure:NOT PROVIDED
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. CONSULT A PHYSICIAN. EYE
CONTACT: IMMEDIATELY RINSE WITH CLEAN WATER FOR 15 MINUTES. SEEK
MEDICAL ATTENTION IF PAIN, BLINKING, TEARS OR REDNESS PERSISTS.
SKIN CONTACT: WASH WITH SOAP AND WATER. INGESTION: DO NOT INDUCE
VOMITING. KEEP PERSON WARM AND QUIET, AND GET MEDICAL ATTENTION.
ASPIRATION OF MATERIAL INTO THE LUNGS DUE TO VOMITING CAN CAUSE
CHEMICAL PNEUMONITI S WHICH CAN BE FATAL.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:=168.3C, 335.F
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NOT AVAILABL
Upper Limits:NOT AVAILABL
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WATER OR FOAM MAY CAUSE FROTHING WHICH CAN BE
VIOLENT ESPECIALLY IF SPRAYED INTO CONTAINERS OF HOT, BURNING
LIQUID. WATER MAY BE USED TO KEEP FIRE-EXPOSED CONTAINERS COOL
UNTIL FIRE IS OUT. WEAR SELF- CONTAINED BREATHING APPARATUS WITH A
FULL FACE PIECE OPERATED IN THE POSITIVE PRESSURE DEMAND MODE WHEN
FIGHTING FIRES.
Unusual Fire/Explosion Hazard:NEVER USE WELDING OR CUTTING TORCH ON OR
NEAR DRUM (EVEN EMPTY). PRODUCT, EVEN RESIDUE CAN IGNITE
EXPLOSIVELY.
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL SPILL: ABSORB ON VERMICULITE, FLOOR
ABSORBENT OR OTHER ABSORBENT MATERIAL. LARGE SPILL: STOP SPILL AT
SOURCE, DIKE, AND PUMP INTO SUITABLE CONTAINERS. REMAINING LIQUID
MAY BE TAKEN UP ON SAND, CLAY, EARTH, FLOOR ABSORBENT/OTHER
ABSORBENT MATERIAL AND SHOVELED INTO CONTAINERS. PREVENT RUN-OFF TO
SEWERS, STREAMS/ OTHER BODIES OF WATER. IF RUN-OFF OCCURS, NOTIFY
PROPER AUTHORITIES AS REQUIRED.
Neutralizing Agent:NOT RELEVANT
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT WITH EYES, SKIN AND
CLOTHING. WASH THOROUGHLY AFTER HANDLING. NEVER USE WELDING OR
CUTTING TORCH ON OR NEAR DRUM
Other Precautions:NOT PROVIDED
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE UNDER NORMAL USE.
Ventilation:GENERAL ROOM VENTILATION.
Protective Gloves:WEAR RESISTANT GLOVES, SUCH AS NITRILE RUBBER,
POLYETHYLENE.
Eye Protection:GOGGLES AND/OR FACE SHIELD MUST BE WORN IF SPLASHING OR
SPRAYING LIQUID.
Other Protective Equipment:WEAR LONG SLEEVED SHIRT,TROUSERS, SAFETY
SHOES.
Work Hygienic Practices:PRACTICE GOOD PERSONAL HYGIENE. WASH HANDS AND
OTHER EXPOSED AREAS WITH MILD SOAP AND WATER.
Supplemental Safety and Health
NONE
================== Physical/Chemical Properties ==================
HCC:V5
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:>100.C, 212.F
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Density:>10.0
Spec Gravity:0.924
pH:NOT RELEVANT
Viscosity:NOT PROVIDED
Evaporation Rate & Reference:<1, ETHER=1
Solubility in Water:FORMS EMULSION
Appearance and Odor:RED LIQUID, MILD DETERGENT ODOR
Corrosion Rate:NOT PROVIDED
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NOT PROVIDED
Hazardous Decomposition Products:BURNING CAN PRODUCE CARBON MONOIXDE
AND/OR CARBON DIOXIDE, VARIOUS HYDROCARBONS, ETC.
=================== Toxicological Information ===================
Toxicological Information:NOT PROVIDED
===================== Ecological Information =====================
Ecological:NOT PROVIDED
==================== Disposal Considerations ====================
Waste Disposal Methods:SMALL SPILL: DISPOSE OF IN ACCORDANCE WITH ALL
LOCAL, STATE AND FEDERAL REGULATIONS. LARGE SPILL: DISPOSE OF IN
ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS.
=================== MSDS Transport Information ===================
Transport Information:DOT HAZARDOUS MATERIAL: PROPER SHIPPING NAME: NOT
APPLICABLE. DOT HAZARD CLASS: NOT APPLICABLE.
===================== Regulatory Information =====================
SARA Title III Information:NOT PROVIDED
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:NOT PROVIDED
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|