===================== Product Identification =====================
MSDS NAME:THALLOUS CHLORIDE TI201 INJECTION
NIIN:00F047808
MSDS Number: CGHJQ
=== Responsible Party ===
Company:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Info Phone Num:314-770-7800/314-895-2000
Emergency Phone Num:314-770-7800
CAGE:FO650
=== Contractor Identification ===
Company:MALLINCKRODT DIAGNOSTICS
Address:2703 WAGNER PLACE
Box:City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-344-3800
CAGE:2A916
Company:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-770-7800/314-895-2000
CAGE:FO650
============= Composition/Information on Ingredients =============
Name:THALLOUS CHLORIDE T1 201 *97-4*
CAS:55172-29-7
Fraction by Wt: 0.001%
Name:SODIUM CHLORIDE *97-4*
CAS:7647-14-5
RTECS #:VZ4725000
Fraction by Wt: 0.9%
Name:BENZYL ALCOHOL
CAS:100-51-6
RTECS #:DN3150000
Fraction by Wt: 0.9%
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 99%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE ASYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS/TISSUES. HEALTH
RISKS CAUSED BY RADIATION EXPOSURE ARE: CANCER, LEUKEMIA, GENETIC &
TERATOGENIC EFFECTS WHICH MAY BE CA USED WHEN LEVELS OF RADIATION
EXPOSURE ARE MUCH HIGHER THAN THOSE PERMITTED OCCUPATIONALLY.
Explanation of Carcinogenicity:NONE
======================= First Aid Measures =======================
First Aid:INGESTION: NOTIFY RADIATION SAFETY PERSONNEL IMMEDIATELY. THE
AMOUNT OF MATERIAL INHALED/INGESTED SHOULD BE ASSESSED &
DOCUMENTED. SKIN: WASH THOROUGHLY W/SOAP & WATER UNTIL NO MORE
RADIOACTIVITY CAN BE REMOVED. ALWAYS BLOT DRY. DON'T ABRADE SKIN.
EYES: WASH W/WATER FOR 15 MINS/UNTIL NO MORE RADIOACTIVITY CAN BE
REMOVED. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH-APPROVED
SELF CONTAINED BREATHING APPARATUS W/FULL FACEPIECE OPERATED IN THE
PRESSURE DEMAND/OTHER POSITIVE PRESSURE MODE.
================== Accidental Release Measures ==================
Spill Release Procedures:IF A PRODUCT IS RECEIVED IN A LEAKING
CONDITION/ANY LOSS/RELEASE OF THE RADIOACTIVE CONTENTS OCCURS,
NOTIFY THE RADIATION SAFETY DEPT & MALLINCKRODT. ALL CLEANUP
OPERATIONS SHOULD BE PERFORMED ACCORDI NG TO THE STANDARD OPERATING
PROCEDURES.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AT 59-85F. HANDLING TIME SHOULD
BE KEPT TO A MINIMUM. USE HANDLING DEVICES SUCH AS SYRINGE SHIELDS
& TONGS. READ PACKAGE INSERT PRIOR TO USE.
Other Precautions:BECAUSE THIS PRODUCT IS INTENDED FOR USE BY
HOSPITAL/CLINIC PATIENTS, IT IS EXPECTED TO BE TREATED BY STANDARD
WASTEWATER TREATMENT FACILITIES W/NO ADVERSE ENVIRONMENTAL IMPACTS.
RADIOACTIVE DRUGS MUS T BE HANDLED BY QUALIFIED PERSONNEL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT REQUIRED
Ventilation:NOT REQUIRED
Protective Gloves:DISPOSABLE PLASTIC, LATEX/RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT
Work Hygienic Practices:NO SMOKING, EATING/DRINKING SHOULD BE ALLOWED
IN ANY AREA WHERE RADIOACTIVE MATERIALS ARE HANDLED/STORED.
Supplemental Safety and Health
THE VIAL CONTAINING THE DRUG SHOULD BE KEPT W/IN ITS CONTAINER/W/IN
HEAVIER SHIELDING. AVOID CONTACT W/THE RADIOACTIVE CONTENTS WHICH
WOULD CAUSE UNNECESSARY EXPOSURE TO RADIATION.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F
Melt/Freeze Pt:M.P/F.P Text:32F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID IN A 10 ML GLASS VIAL W/NO
ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEATING
Hazardous Decomposition Products:RADIOACTIVE FUMES
==================== Disposal Considerations ====================
Waste Disposal Methods:IF MEDICAL WASTE IS INVOLVED, SUCH AS BLOOD,
BLOOD PRODUCTS/SHARPS, THE WASTE MUST BE HANDLED AS A BIOHAZARD &
DISPOSED OF IAW/LOCAL, STATE & FEDERAL REGULATIONS. RADIOACTIVE
MATERIAL UN2982.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***