===================== Product Identification =====================
MSDS NAME:CALIBRATION KIT FOR HIAC/ROYCO SENSORS, ACF
NIIN:01-288-8102
Status Code:A
MSDS Number: CJDTV
=== Responsible Party ===
Company:PACIFIC SCIENTIFIC CO., HIAC/ROYCO DIV
Address:11801 TECH ROAD
City:SILVER SPRING
State:MD
ZIP:20910
Country:US
Info Phone Num:301-6807088
Emergency Phone Num:301-680-7000
CAGE:15887
=== Contractor Identification ===
Company:PACIFIC SCIENTIFIC INSTRUMENTS HIAC ROYCO DIV
Address:481 CALIFORNIA AVE
Box:City:GRANTS PASS
State:OR
ZIP:97526-1909
Country:US
Phone:641-479-1242 / FAX: 641-479-3057
Contract Num:SP044099F0116
CAGE:15887
============= Composition/Information on Ingredients =============
Name:HYDROTREATED LIGHT NAPHTHENIC DISTILLATE
> Wt:80.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 OIL MIST
ACGIH TLV:5 MG/M3 OIL MIST
Name:AC FINE TEST DUST
< Wt:1.
Other REC Limits:NONE RECOMMENDED
Name:OTHER COMPONENTS (TYPE NOT SPECIFIED)
< Wt:20.
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MAY BE IRRITATING. SKIN:
PROLONGED/REPEATED CONTACT MAY CAUSE DERMATITIS, FOLLICULITIS, OR
OIL ACNE. RELEASE DURING HIGH PRESSURE USAGE MAY RESULT IN
INJECTION OF OIL INTO SKIN CAUSING LOCAL NEC ROSIS. INHALATION:IN
HIGH CONC., VAPOR IS IRRITATING TO MUCOUS MEMBRANES AND IS
ANESTHETIC. INGESTION:LOW ORDER OF TOXICITY, BUT MAY CAUSE
GASTROINTESTINAL DISTURBANCES SUCH AS CATHARSIS. ASPIRATION W ITH
SUBSEQUENT PULMONARY INFILTRATION MAY OCCUR.
Explanation of Carcinogenicity:NONE OF THE CHEMICALS IN THIS PRODUCT IS
LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
======================= First Aid Measures =======================
Eyes:FLUSH WITH WATER FOR 15 MIN. WHILE HOLDING EYELIDS OPEN.
GET MEDICAL ATTENTION. SKIN:REMOVE CONTAMINATED CLOTHING AND WIPE
EXCESS OFF. WASH WITH SOAP AND WATER OR A WATERLESS HAND CLEANER
FOLLOWE D BY SOAP AND WATER. DO NOT REUSE CLOTHING UNTIL THOROUGHLY
CLEANED. GET MEDICAL ATTENTION IF NEEDED. IF MATERIAL IS INJECTED
UNDER THE SKIN, GET MEDICAL ATTENTION. INHALTION:REMOVE VICTIM TO
FRESH AI R & PROVIDE OXYGEN IF BREATHING IS DIFFICULT. INGESTION:DO
NOT INDUCE VOMITING. GIVE 1/2 PINT OF MILK OR WATER. IF VOMITING
OCCURS, KEEP HEAD LOWER THAN HIPS TO PREVENT ASPIRATION. KEEP
VICTIM WARM & AT REST. SEEK DOCTOR.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:=85.C, 185.F
Lower Limits:1%
Upper Limits:7%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER, OR FOAM
EXTINGUISHER. DO NOT USE WATER JET.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.
================== Accidental Release Measures ==================
Spill Release Procedures:TAKE UP WITH DIATOMACEOUS EARTH, CLAY OR OTHER
INERT ABSORBENT AND PLACE IN COTNAINER FOR LATER DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE WTIH
ADEQUATE VENTILATION. KEEP AWAY FROM OPEN FLAMES AND HIGH
TEMPERATURES.
Other Precautions:DO NOT GET IN EYES, OR ON CLOTHING. KEEP AWAY FROM
SPARKS AND OPEN FLAMES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NORMALLY REQUIRED. IF NEEDED THOUGH, USE A
NIOSH-APPROVED RESPIRATOR TO PREVENT OVEREXPOSURE. IN ACCORD WITH
29 CFR 1910.134 USE EITHER AN ATMOSPHERE SUPPLYING RESPIRATOR OR AN
AIR-PURIFYING RESPI RATOR FOR ORGANIC VAPORS AND PARTICULATES.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:USE OIL RESISTANT GLOVES
Eye Protection:NONE SPECIFIED BY MANUFACTURERE.
Other Protective Equipment:CLOTHING AS NEEDED TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE
EATING,DRINKING,SMOKING, OR USING TOILET FACILITIES. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE. DISPOSE OF CONTAMINATED
LEATHER ARTICLES THAT CANNOT BE DECONTAMINATED.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:=154.4C, 310.F
Vapor Density:>5
Spec Gravity:0.85
Solubility in Water:INSOLUBLE
Appearance and Odor:RED CLEAR FLUID, SLIGHT PETROLEUM ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT, OPEN FLAMES AND OTHER SOURCES OF
IGNITION
Hazardous Decomposition Products:CARBON MONOXIDE AND UNIDENTIFIED
ORGANIC COMPOUNDS MAY BE FORMED UPON COMBUSTION.
===================== Ecological Information =====================
Ecological:THE COMPONENTS OF THIS PRODUCT ARE LISTED ON THE EPA/TSCA
INVENTORY OF CHEMICAL SUBSTANCES. THIS PRODUCT IS CLASSIFIED AN AN
OIL UNDER SECTION 311 OF THE CLEAN WATER ACT. SPILLS ENTERING A)
SURFACE WA TERS OR B) ANY WATER COURSES OR SEWERS ENTERING/LEAVING
TO SURFACE WATERS THAT CAUSE A SHEEN MUST BE REPORTED TO THE
NATIONAL RESPONSE CENTER. 800-424-8802.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN AN APPROPRIATE DISPOSAL FACILITY
IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|