===================== Product Identification =====================
MSDS NAME:FORANE 134A
NIIN:01-370-6207
Status Code:A
MSDS Number: CJQCF
=== Responsible Party ===
Company:ELF AUTOCHEM NORTH AMERICA FLUOROCHEMICALS
Address:2000 MARKET ST
City:PHILADELPHIA
State:PA
ZIP:19103-3222
Country:US
Info Phone Num:215-419-7704\7695
Emergency Phone Num:215-419-7695\7704
Chemtrec Ind/Phone:(800)424-9300
CAGE:TO328
=== Contractor Identification ===
Company:ELF ATOCHEM NORTH AMERICA INC
Address:2000 MARKET STREET
Box:City:PHILADELPHIA
State:PA
ZIP:19103-3222
Country:US
Phone:800-245-5858
CAGE:86460
Company:ELF AUTOCHEM NORTH AMERICA FLUOROCHEMICALS
Address:2000 MARKET ST
Box:City:PHILADELPHIA
State:PA
ZIP:19103-3222
Country:US
Phone:215-419-7704\7695
CAGE:TO328
Company:REFRIGERANT RECLAIM SERVICES INC / DBA FULL CYCLE
Address:121 S NORWOOD DR
Box:City:HURST
State:TX
ZIP:76053
Country:US
Phone:817-282-0022
Contract Num:SP0450-99-C5460
CAGE:0YD89
============= Composition/Information on Ingredients =============
Name:1,1,1,2-TETRAFLUOROETHANE (R134A)
CAS:811-97-2
Fraction by Wt: 100%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: CNS, RESPIRATORY SYSTEM
AND HEART. EYES: VERY SLIGHT IRRITATION. RAPID VOLATILIZATION OF
LIQUID MAY CAUSE FROSTBITE. SKIN: SLIGHT IRRITANT, CONTACT MAY
CAUSE FROSTBITE. INHALATION: CONC ENTRATED VAPORS CAN PRODUCE RAPID
ANESTHETIC EFFECTS, RESPIRATORY DEPRESSION, INCREASED SENSITIVITY
OF THE HEART TO ADRENALINE, DEPRESSION OF CARDIAC FUNCTION, DEATH
DUE TO ASPHYXIATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, FROSTBITES AND PAIN, DROWSINESS,
UNCONSCIOUSNESS, RAPID HEARTBEAT, IRREGULAR HEARTBEAT.
Medical Cond Aggravated by Exposure:PREEXISTING HEART DISEASE OR
COMPROMISED HEART FUNCTION SHOULD ONLY HAVE LIMITED EXPOSURE TO
THIS MATERIAL.
======================= First Aid Measures =======================
First Aid:SKIN: IF FROSTBITTEN, WARM SLOWLY W/WATER. FLUSH W/PLENTY OF
WATER. EYES: FLUSH W/PLENTY OF CLEAN WATER FOR 15 MINS. INHALATION:
REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR. IF BREATHING IS
DIFFIC ULT, GIVE OXYGEN. INGESTION: NEVER GIVEANYTHING BY MOUTH TO
AN UNCONSCIOUS PERSON. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Autoignition Temp:Autoignition Temp Text:N/E
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
FIRE CONDITIONS.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS IF
FIGHTING FIRES NEAR THIS PRODUCT DUE TO TOXICITY OF THERMAL
DECOMPOSITION PRODUCTS.KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:MIXTURES OF HFC-134A WITH AIR OR OTHER
OXIDIZERS UNDER HIGH TEMPERATURE AND PRESSURE, CAN BE FLAMMABLE.IN
TESTS CONDUCTED AT UP TO 170C, HFC-134A IS FLAMMABLE ONLY AT
PRESSURES ABOVE 50PSIA AND WITH M ORE THAN 50% AIR BY
VOLUME.MIXTURES CONTAINING HFC-134A SHOULD NOT BE USED FOR PRESSURE
OR LEAK TESTING.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE/EXTINGUISH IGNITION/COMBUSTION SOURCES.
EVACUATE ENCLOSED SPACES UNTIL GAS IS DISPERSED. KEEP UPWIND. STOP
LEAK IF POSSIBLE W/OUT RISK. DISPERSE GAS W/FLOOR-LEVEL FORCED-AIR
VENTILATION. EXHAUS T VAPORS OUTDOORS. REMOVE FLAMES/HEAT
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM IGNITION SOURCES AND
DIRECT SUNLIGHT. STORE BELOW 120F. STORE IN TIGHTLY CLOSED
CONTAINES. DO NOT REFILL THIS CYLINDER. EMPTY CONTAINERS CONTAIN
HAZARDOUS RESIDUE.
Other Precautions:DON'T DROP, REUSE/REFILL CONTAINER. DON'T CUT, GRIND/
WELD ON/NEAR CONTAINER. DON'T GET IN EYES, ON SKIN/CLOTHING. DON'T
BREATHE VAPOR, MIST/GAS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IN INADEQUATELY VENTILATED AREAS, A NIOSH/MSHA
APPROVED (TC-18C) SUPPLIED AIR RESPIRATOR/SCBA IS REQUIRED.
Ventilation:CHECK AIR FOR CONTAMINANT & FOR OXYGEN DEFICIENCY. USE
LOCAL EXHAUST SYSTEM IF VENTILATION IS INADEQUATE.
Protective Gloves:SYNTHETIC RUBBER/NEOPRENE
Eye Protection:CHEMICAL GOGGLES
Other Protective Equipment:WEAR APPROPRIATE CHEMICAL RESISTANT
PROTECTIVE CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. DESTROY CONTAMINATED SHOES.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:=-26.3C, -15.5F
Melt/Freeze Pt:=-101.C, -149.8F
Vapor Pres:96.16 PSIA @77F
Vapor Density:3.52
Spec Gravity:1.21 @ 77F
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUIFIED GAS WITH FAINT
ETHEREAL(ETHER-LIKE) ODOR
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ALKALI OR ALKALINE EARTH METALS, ALUMINUM,
MAGNESIUM/ZINC & STRONG OXIDIZERS SINCE THEY MAY REACT WITH OR
ACCELERATE DECOMPOSITION OF THIS MATERIAL.
Stability Condition to Avoid:THERMAL DECOMPOSITION DUE TO EXPOSURE TO
HEAT(>800F) OR FIRE FLAMES,EXTREMELY HOT METAL SURFACES,HEATING
ELEMENTS,COMBUSTION ENGINES,ETC
Hazardous Decomposition Products:HYDROGEN FLUORIDE, CO, CO2
=================== Toxicological Information ===================
Toxicological Information:INHALATION: 4 HR LC50 RATS= 500,000 PPM; 30
MIN LC50= 750,000 PPM. CONCENTRATION >50,000 PPM PRODUCED
ANESTHETIC EFFECT IS MICE, DOG, CATS AND MOKEYS. NO TOXIC EFFECTS
WERE OBSERVED IN RATS EXPOSED 6 HR/DAY, 5 DAYS/WEEK FOR 13 WEEKS
FOR CONCENTRATIONS UPTO 50,000 PPM. INHALATION FOLLOWED BY IV
INJECTION OF EPINEPHRINE RESULTED IN HEART SENSITIZATIONS AT LEVELS
>75,000 PPM IN DOGS.
===================== Ecological Information =====================
Ecological:A 28 DAY BIODEGRADATION STUDY WITH HFC 134A USING AN
ACTIVATED SLUDGE INOCULUM PRODUCED 3% BIODEGRADATION.
==================== Disposal Considerations ====================
Waste Disposal Methods:RECYCLE/RECLAIM IF POSSIBLE. RECLAIMED MATERIAL
MAY BE INCINERATED BUT TOXIC & CORROSIVE COMBUSTION PRODUCTS(HF &
HCL) MUST BE HANDLED APPROPRIATELY. DISPOSE OF IAW/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|