Search   
MSDS  
:
 NICKEL CADMIUM BATTERY
CAS  
:
 7440-43-9
7440-48-4
1310-65-2
7440-02-0
1310-58-3
1310-73-2
NAME  
:
 cadmium (as cadmium metal, 7440-43-9; cadmium oxide,
cobalt (as cobalt metal, 7440-48-4; cobalt oxide,
lithium hydroxide
nickel (as nickel metal, 7440-02-0; nickel oxide,
potassium hydroxide
sodium hydroxide
=====================  Product Identification  =====================

MSDS NAME:NICKEL CADMIUM BATTERY
NIIN:00N093104
Status Code:A
MSDS Number: CJWRM
=== Responsible Party ===
Company:ENERGIZER POWER SYSTEM, DIV. OF EVEREADY BATTERY
Address:US HIGHWAY 441N
City:ALACHUA
State:FL
ZIP:32615
Country:US
Info Phone Num:440-835-7368
Emergency Phone Num:440-835-7368
CAGE:EO263
=== Contractor Identification ===
Company:ENERGIZER POWER SYSTEM, DIV. OF EVEREADY BATTERY
Address:US HIGHWAY 441N
Box:City:ALACHUA
State:FL
ZIP:32615
Country:US
Phone:440-835-7368
CAGE:EO263

=============  Composition/Information on Ingredients  =============

Name:CADMIUM (AS CADMIUM METAL, 7440-43-9; CADMIUM OXIDE,
    1306-19-0; CADMIUM HYDROXIDE, 21041-95-2). ACGIH TLV: 0.002 MG/M3
    RDUST (M).
CAS:7440-43-9
RTECS #:EU9800000
Minumum % Wt:13.
Maxumum % Wt:22.
OSHA PEL:5 MG/M3
ACGIH TLV:0.01 MG/M3
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:COBALT (AS COBALT METAL, 7440-48-4; COBALT OXIDE,
    1307-96-6; COBALT HYDROXIDE, 21041-93-0).
CAS:7440-48-4
RTECS #:GF8750000
Minumum % Wt:.5
Maxumum % Wt:2.
OSHA PEL:0.1 MG/M3
ACGIH TLV:0.02 MG/M3

Name:LITHIUM HYDROXIDE
CAS:1310-65-2
RTECS #:OJ6307070
Minumum % Wt:0.
Maxumum % Wt:4.

Name:NICKEL (AS NICKEL METAL, 7440-02-0; NICKEL OXIDE,
    1313-99-1, NICKEL HYDROXIDE, 12054-48-7).
CAS:7440-02-0
RTECS #:QR5950000
Minumum % Wt:20.
Maxumum % Wt:32.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3

Name:POTASSIUM HYDROXIDE
CAS:1310-58-3
RTECS #:TT2100000
Minumum % Wt:0.
Maxumum % Wt:4.
ACGIH TLV:C2 MG/M3
ACGIH STEL:C2 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:SODIUM HYDROXIDE
CAS:1310-73-2
RTECS #:WB4900000
Minumum % Wt:0.
Maxumum % Wt:4.
OSHA PEL:2 MG/M3
ACGIH TLV:C2 MG/M3
ACGIH STEL:C2 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS OF USE,
    BATTERY IS HERMETICALLY SEALED. INGESTION: SWALLOWING CAN BE
    HARMFUL. CONTENTS OF OPEN BATTERY CAN CAUSE SERIOUS CHEMICAL BURNS
    OF MOUTH, ESOPHAGUS AND GASTROINTESTINAL  TRACT. CONTENTS INCLUDE
    TOXIC CADMIUM AND CADMIUM COMPOUNDS WHICH CAN CAUSE EXCESSIVE
    SALIVATION, CHOKING, NAUSEA, PERSISTENT VOMITING, DIARRHEA,
    ABDOMINAL PAIN, DIZZINESS, FAINTNESS, UNCONSCIOUSNESS  AND POSSIBLE
    LIVER AND KIDNEY INJURY. INHALATION: CONTENTS OF OPEN BATTERY CAN
    CAUSE RESPIRATORY IRRITATION. CADMIUM OXIDE FUMES CAN CAUSE METAL
    FUME FEVER. HYPERSENSITIVITY TO NICKEL CAN CAUSE ALLER GIC
    PULMONARY ASTHMA. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CADMIUM:IARC MONOGRAPHS, SUPP, VOL 58,
    PG 119, 1997:GRP 1. NTP 8TH ANNUAL RPT ON CARCINS, 1998:ANTIC TO BE
    CARCIN. HUMAN:LUNG, PROSTATE, RENAL SYS EFTS. OSHA REGULATED:29 CFR
    1910.1027. CADMIUM OXIDE: IARC MONOGRAPHS, SUPP, VOL 7, PG 127,
    1987:GRP 2A. NTP 8TH ANNUAL RPT ON CARCINS, 1998:ANTIC TO BE
    CARCIN. COBALT:IARC MONOGRAPHS ON EVAL OF CARCIN (SUPP DATA)
Effects of Overexposure:HLTH HAZ: SKIN CONTACT: CONTENTS OF OPEN
    BATTERY CAN CAUSE IRRITATION AND/OR CHEMICAL BURNS. COBALT, COBALT
    COMPOUNDS, NICKEL AND NICKEL COMPOUNDS CAN CAUSE SENSITIZATION AND
    ALLERGIC CONTACT DERMATIT IS. EYE CONTACT: CONTENTS OF OPEN BATTERY
    CAN CAUSE SEVERE IRRITATION AND CHEMICAL BURNS. NOTE: CADMIUM
    APPEARS ON THE NAVY LIST OF OCCUPATIONAL CHEMICAL REPRODUCTIVE
    HAZARDS. SEEK CONSULTATION FROM A PPROPRIATE HEALTH PROFESSIONALS
    CONCERNING LATEST HAZARD LIST INFORMATION AND SAFE HANDLING AND
    EXPOSURE INFORMATION .

=======================  First Aid Measures  =======================

First Aid:INGESTION: DO NOT INDUCE VOMITING OR GIVE FOOD OR DRINK. SEEK
    MEDICAL ATTENTION IMMEDIATELY. CALL NATIONAL BATTERY INGESTION
    HOTLINE FOR ADVICE AND FOLLOW-UP (202-625-3333) COLLECT, DAY OR
    NIGHT. INHA LATION: PROVIDE FRESH AIR AND SEEK MEDICAL ATTENTION.
    SKIN: REMOVE CONTAMINATED CLOTHING AND WASH SKIN WITH SOAP AND
    WATER. IF A CHEMICAL BURN OCCURS OR IF IRRITATION PERSISTS, SEEK
    MEDICAL ATTENTION.	EYES: IMMEDIATELY FLUSH THOROUGHLY WITH WATER
    FOR AT LEAST 15 MINUTES, LIFTING UPPER AND LOWER LIDS, UNTIL NO
    EVIDENCE OF CHEMICAL REMAINS. SEEK MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:IN CASE OF FIRE, IT IS PERMISSIBLE TO USE ANY CLASS
    OF EXTINGUISHING MEDIUM ON THESE BATTERIES OR THEIR PACKING
    MATERIALS.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT . COOL EXTERIOR OF BATTERIES IF EXPOSED TO FIRE TO
    PREVENT RUPTURE.
Unusual Fire/Explosion Hazard:IF FIRE OR EXPLOSION OCCURS WHEN
    BATTERIES ARE ON CHARGE, SHUT OFF POWER TO CHARGER. NICKEL-CADMIUM
    BATTERIES INVOLVED IN A FIRE CAN VENT AND PRODUCE TOXIC FUMES
    INCLUDING NICKEL, NICKEL OXIDES, CADMI UM, CADMIUM OXIDES AND
    COBALT OXIDES.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, WELL-VENTED AREA.
    ELEVATED TEMPS CAN RSLT IN SHORTENED BATTERY LIFE. BATTERY SHOULD
    NOT BE OPENED/BURNED. SHOULD CELL BECOME DISASSEMBLED, ELECTRODE
    SHOULD BE STORED IN FIREPROOF CABINE T, AWAY FROM COMBUSTS. EXPOS
    TO INGS CONTAINED WITHIN OR THEIR COMBUSTION PRODS COULD BE
    HARMFUL.
Other Precautions:MECH CONTAINMENT:IF POTTING/SEALING BATTERY IN
    AIRTIGHT/WATERTIGHT CNTNR IS REQD, CONSULT YOUR EVEREADY BATTERY CO
    REPRESENTATIVE FOR PRECAUTIONARY SUGGESTIONS. BATTERIES NORMALLY
    EVOLVE HYDROGEN WHIC H, WHEN COMBINED W/OXYG FROM AIR, CAN PRDCE
    COMBUST/EXPLO MIXT UNLESS VENTED. IF SUCH MIXT IS PRESEN T, (OTHER
    INFO)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NOT NECESSARY UNDER NORMAL CONDITIONS.
Ventilation:NOT NECESSARY UNDER NORMAL CONDITIONS.
Protective Gloves:NEOPRENE OR NATURAL RUBBER GLOVES (IF HANDLING OPEN
    OR LEAKING BATTERY).
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Supplemental Safety and Health
EXPLAN OF CARCIN:RISK OF CHEMS TO MAN, VOL 52, PG 363, 1991:GRP 2B.
    ANIMAL:PULM FIBROSIS (BLOOD EFTS). COBALT OXIDE & COBALT
    HYDROXIDE:IARC MONOGRAPHS ON EVAL OF CARCIN RISK OF CHEMS TO MAN,
    VOL 52, P G 363, 1991:GRP 2B. NICKEL:IARC MONOGRAPHS ON EVAL OF
    CARCIN RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GRP (OTHER INFO)

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:NICKEL-CADMIUM BATTERIES INVOLVED IN
    FIRE CAN VENT & PRODUCE TOXIC FUMES INCLUDING NICKEL, NICKEL
    OXIDES, CADMIUM, CADMIUM OXIDES, AND COBALT OXIDES.

===================  Toxicological Information	===================

Toxicological Information:OTHER INFO:BATTERY IS CAPABLE OF DELIVERING
    VERY HIGH SHORT CIRCUIT CURRENTS. PRLNG SHORT CIRCUITS WILL CAUSE
    HIGH CELL TEMPS WHICH CAN CAUSE SKIN BURNS. SOURCES OF SHORT
    CIRCUITS INCL JUMBLED BATTERI ES IN BULK CNTNRS, METAL JEWELRY &
    METAL COVERED TABLES/METAL BELTS USED FOR ASSEMBLY OF BATTERIES
    INTO DEVICES. IF SOLDERING/WELDING TO BATTERY IS REQD, USE OF
    TABBED BATTERIES IS REC. IF THIS CANNOT  BE DONE, CONSULT YOUR
    EVEREADY BATTERY CO REPRESENTATIVE FOR PROPER PRECS TO PVNT SEAL
    DMG/SHORT CIRCUIT. DO NOT OPEN BATTERY. NEGATIVE ELECTRODE MATL MAY
    BE PYROPHORIC. SHOULD AN INDIVIDUAL CELL FRO M BATTERY BECOME
    (ECOLOGICAL INFO)

=====================  Ecological Information  =====================

Ecological:WASTE DISP METH: BATTERIES. THE FED "UNIVERSAL WASTE RULE"
    CITED AT 40 CFR PART 273 GOVERNS NICKEL CADMIUM BATTERY RECYCLING &
    MAY BE APPLIC IN YOUR STATE. -- TOX INFO: DISASSEMBLED, SPONT
    COMBUSTION	OF NEG ELECTRODE IS POSS. THIS IS MUCH MORE LIKELY TO
    HAPPEN IF ELECTRODE IS REMOVED FROM ITS METAL CNTNR. THERE CAN BE
    DELAY BTWN EXPOS TO AIR & SPONT COMBUSTION. CHARGING:THIS BATTERY
    IS MADE TO BE  CHARGED MANY TIMES. BECAUSE IT GRADUALLY LOSES ITS
    CHARGE OVER FEW MONTHS, IT IS GOOD PRACTICE TO CHARGE BATTERY
    BEFORE USE. USE REC CHARGER. IMPROPER CHARGING CAN CAUSE HEAT
    DMG/EVEN HIGH PRESS RUPTU RE. OBSERVE PROPER (TRANSPORT INFO)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE I/A/W ALL APPLIC FED, STATE & LOCAL
    REGS. WHEN GENERATED AS A WASTE, THESE BATTERIES MAY BE REGULATED
    BY THE RCRA AS A D006 (CADMIUM) HAZ WASTE. NOTE: RECYCLING OF THIS
    PROD MAY BE AVAIL. CONT ACT YOUR LOCAL RECYCLING OFFICE OR CALL
    TOLL FREE AT 1-800-8-BATTERY FOR INFO ABOUT HOW & WHERE YOU  CAN
    RECYCLE USED NICKEL CADMIUM (ECOLOGICAL INFO)

===================  MSDS Transport Information  ===================

Transport Information:TRANSPORTATION OF DRY CELL BATTERIES MFRD/SOLD BY
    EVEREADY BATTERY CO IS NOT REGULATED BY U.S. D.O.T./MAJOR
    INTERNATIONAL REGULATORY BODIES. -- ECOLOGICAL INFO: CHARGING
    POLARITY. LABELING:IF EVEREADY  LBL/PACKAGE WARNINGS ARE NOT
    VISIBLE, IT IS IMPORTANT TO PROVIDE PACKAGE &/OR DEVICE LBL
    STATING: NICKEL CADMIUM CONSUMER ROUND CELLS: AA & LGR: WARNING:
    CHARGE ONLY W/STD HOUSEHOLD NICKEL CADMIUM BA TTERY CHARGERS. DO
    NOT OPEN BATTERY, DISP OF IN FIRE, PUT IN BACKWARDS, MIX W/OTHER
    BATTERY TYPES/SHORT CIRCUIT - MAY EXPLODE, LEAK/GET HOT CAUSING
    PERSONAL INJURY. AAA & SMALLER: WARNING: (1) KEEP AW AY FROM SM
    CHILDREN. (SARA TITLE III)

=====================  Regulatory Information  =====================

SARA Title III Information:AS AN ARTICLE, THIS BATTERY AND ITS CONTENTS
    ARE NOT SUBJECT TO THE REQUIREMENTS OF THE EMERGENCY PLANNING AND
    COMMUNITY RIGHT-TO-KNOW ACT. -- TRANSPORT INFO: IF SWALLOWED,
    PROMPTLY SEE MD; HAVE MD PH ONE (202) 625-3333 COLLECT. (2) CHARGE
    ONLY W/STD HOUSEHOLD NICKEL CADMIUM BATTERY CHARGERS. DO NOT OPEN
    BATTERY, DISP OF IN FIRE, PUT IN BACKWARDS, MIX W/OTHER BATTERY
    TYPES/SHORT CIRCUIT - MAY EXPLO DE, LEAK/GET HOT CAUSING PERSONAL
    INJURY. NICKEL CADMIUM INDUSTRIAL ROUND CELLS: (WHERE CHARGE RATE
    IS INDICATED ON LBL) - WARNING: CHARGE ONLY AT SPECIFIED CHARGE
    RATE. DO NOT OPEN BATTERY, DISPOSE O F IN FIRE, (FEDERAL
    REGULATORY)
Federal Regulatory Information:THIS BATTERY IS AN ARTICLE PURSUANT TO
    29 CFR 1910.1200 AND, AS SUCH, IS NOT SUBJECT TO OSHA HAZARD
    COMMUNICATION STANDARD REQUIREMENT FOR PREPARATION OF A MSDS. --
    SARA TITLE III: PUT IN BACKWARDS, M IX W/OTHER BATTERY TYPES/SHORT
    CIRCUIT - MAY EXPLODE, LEAK/GET HOT CAUSING PERSONAL INJURY. ALL
    NICKEL CADMIUM PACKD (OEM AND BRANDED) AND NICKEL CADMIUM OEM ROUND
    CELLS: WARNING: USE ONLY WITH SPECIF IED CHARGERS ACCORDING TO
    CHARGER MFR'S INSTRUCTIONS. DO NOT OPEN BATTERY, DISPOSE OF IN FIRE
    OR SHO RT CIRCUIT - MAY EXPLODE, LEAK OR GET HOT CAUSING PERSONAL
    INJURY.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
FITC ISOMER I, 34321 3326-32-7
N-OCTYL-BETA-D-GLUCOPYRANOSIDE, 494459 29836-26-8
NI-365-2 PRODUCT CODE ZNI365-0210 7440-47-3
7440-02-0
7440-48-4
7440-25-7
7429-90-5
7440-33-7
7440-15-5
7440-58-6
7439-98-7
PEPSIN, PORCINE STOMACH MUCOSA, 516360 9001-75-6
592 RUSTMASTER GLOSS ENAMEL-METALLITE ALUMINUM 136-52-7
67746-08-1
8052-41-3
64742-89-8
1330-20-7
7429-90-5
71-43-2
68131-77-1
68240-01-7
4362 GLID-GUARD SPEED ENAMEL QUICK DRY 1333-86-4
1332-58-7
8052-41-3
64742-16-1
64742-89-8
136-52-7
13463-67-7
71243-64-6
E1215 RITE OFF ISOPROPYL ALCOHOL 67-63-0
124-38-9
NI-365-3 PRODUCT CODE 036173-10 7440-47-3
7440-02-0
7440-48-4
7440-25-7
7429-90-5
7440-33-7
7440-15-5
7440-58-6
7439-98-7
BROWN FUSED ALUMINUM OXIDE 1344-28-1
POD-LABELING KIT, 1829696 16940-66-2
NI-369 PRODUCT CODE: 036131-15 7440-47-3
7440-02-0
7440-48-4
7440-33-7
7440-58-6
7429-90-5
11099-25-5
NI-414 PRODUCT CODE: ZNI414-0010 7440-47-3
7440-02-0
7440-48-4
7440-33-7
7429-90-5
7440-25-7
7440-58-6
SODIUM SILICOFLUORIDE 16893-85-9
NI-386 PRODUCT CODE: 03093-05 7440-47-3
7440-02-0
7440-48-4
7440-32-6
7439-98-7
7429-90-5
610-9159, NICKEL CADMIUM BATTERY 7440-43-9
21041-95-2
7440-02-0
12054-48-7
1310-58-3
MIDALLOY 7439-89-6
7440-47-3
7440-02-0
7439-96-5
7440-21-3
7439-98-7
PURPLE PRIMER NSF, 30755 78-93-3
109-99-9
108-94-1
67-64-1
81-48-1
4477-79-6
SOLARGARD PATCHING CEMENT 13463-67-7
1317-65-3
1318-74-7
CHAMPION CAMOUFLAGE OLIVE, 6-5943, 419-1051 108-88-3
67-64-1
64742-89-8
74-98-6
106-97-8
POTASSIUM IODIDE, 6336 7681-11-0
POTASSIUM IODIDE, 6334 7681-11-0
NICKEL CADMIUM BATTERY 7440-43-9
7440-48-4
1310-65-2
7440-02-0
1310-58-3
1310-73-2
NI-430 PRODUCT CODE: 036141-15 7440-47-3
7440-02-0
7440-21-3
84680 SULFUR 7704-34-9
CHLOROFORM, 9174 67-66-3
64-17-5
0203 SELCOSHINE SS POLISH AEROSOL 64742-48-9
106-97-8
74-98-6
S5889 SODIUM ACETATE ANHYDROUS ACS REAGENT 127-09-3
SERMETEL 249 7429-90-5
7440-66-6
1312-76-1
DIMINAZENE ACETURATE, D7770 908-54-3
NI-449 PRODUCT CODE: ZNI449-0010 7440-47-3
7440-02-0
7440-48-4
7440-21-3
7440-42-8
SONICOR 126 CIRCUIT BOARD CLEANER 141-43-5
34590-94-8
21-220 FORMALIN 10% NEUTRAL 50-00-0
B-GLYCEROPHOSPHATE DISODIUM HYDRATE, G6251 819-83-0
21-636 FORMALIN 10% NEUTRAL 50-00-0
21-637 FORMALIN 10% NEUTRAL 50-00-0
21-638 FORMALIN 10% NEUTRAL 50-00-0
21-639 FORMALIN 10% NEUTRAL 50-00-0
CHLOROFORM, 9175 67-66-3
64-17-5
M5005, MANGANESE CHLORIDE TETRAHYDRATE INSECT CELL (SUPDAT) 13446-34-9
T4128, TRIZMA PRE-SET PH CRYSTALS REAGENT (SUPDAT)
NI-453 PRODUCT CODE: 036123-10 7440-02-0
7439-98-7
7429-90-5
DOTRIACONTANE, D4634 544-85-4
CHLOROFORM 9180 67-66-3
64-17-5
NI-489 PRODUCT CODE: 036140-15 7440-02-0
7440-21-3
11099-25-5
CHLOROFORM, 9181 67-66-3
64-17-5
NIFLUMIC ACID N0630 4394-00-7
HOOFMARK CITRUS DEGREASER AEROSOL 75-28-5
74-98-6
497-19-8
5989-27-5
7732-18-5
BIOHYD (ALL GRADES)
2838 LIQUID 111-30-8
NI-530 PRODUCT CODE: 036163-10 7440-47-3
7440-02-0
7440-21-3

Free MSDS Search ( Providing 250,000+ Material Properties )