Search   
MSDS  
:
 LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY)
CAS  
:
 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
7664-93-9
9003-07-0
60676-86-0
NAME  
:
 lead
antimony
arsenic
calcium
tin
sulfuric acid
polypropylene
silicon dioxide (for gel cell batteries only)
=====================  Product Identification  =====================

MSDS NAME:LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY)
Status Code:A
MSDS Number: CKRBW
=== Responsible Party ===
Company:EXIDE CORP
Address:645 PENN STREET
Box:14205
City:READING
State:PA
ZIP:19612-4205
Country:US
Info Phone Num:610-378-0500/0798
Emergency Phone Num:800-424-9300
Preparer's Name:REGULATROY AFFAIRS DEPT
Chemtrec Ind/Phone:(800)424-9300
CAGE:20038
=== Contractor Identification ===
Company:EXIDE CORP
Address:645 PENN STREET
Box:14205
City:READING
State:PA
ZIP:19612-4205
Country:US
Phone:610-378-0500/0798
CAGE:20038

=============  Composition/Information on Ingredients  =============

Name:LEAD
CAS:7439-92-1
RTECS #:OF7525000
= Wt:53.
OSHA PEL:0.05 MG/M3
ACGIH TLV:0.15 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:ANTIMONY
CAS:7440-36-0
RTECS #:CC4025000
= Wt:.2
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:ARSENIC
CAS:7440-38-2
RTECS #:CG0525000
Fraction by Wt: 0.003%
OSHA PEL:.01 MG/M3
ACGIH TLV:0.01 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:CALCIUM
CAS:7440-70-2
RTECS #:EV8040000
= Wt:.02

Name:TIN
CAS:7440-31-5
RTECS #:XP7320000
= Wt:.06
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3

Name:SULFURIC ACID
CAS:7664-93-9
RTECS #:WS5600000
Minumum % Wt:30.
Maxumum % Wt:40.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
ACGIH STEL:3 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:POLYPROPYLENE
CAS:9003-07-0
RTECS #:UD1842000
Minumum % Wt:5.
Maxumum % Wt:6.

Name:SILICON DIOXIDE (FOR GEL CELL BATTERIES ONLY)
CAS:60676-86-0
RTECS #:VV7328000
Minumum % Wt:3.
Maxumum % Wt:5.
OSHA PEL:SEE TABLE Z-3
ACGIH TLV:0.1 MG/M3

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:ELECTROLYTE: HARMFUL BY ALL ROUTES OF
    ENTRY, CAUSES SEVERE IRRITATION AND BURNS, CORNEAL
    DAMAGE/BLINDNESS.  LEAD COMPOUNDS: HAZARDOUS EXPOSURE CAN OCCUR
    ONLY WHEN PRODUCT IS HEATED ABOVE THE MELTING P OINT, OXIDIZED OR
    OTHERWISE PROCESSED/ DAMAGED TO CREATE DUST, VAPOR OR FUME.  LEAD
    DUST OR FUMES MAY CAUSE IRRITATION OF UPPER RESPIRATORY TRACT,
    LUNGS, SKIN AND EYES. CHRONIC:ELECTROLYTE: EROSION OF  TOOTH
    ENAMLE, INFLAMMATION OF NOSE, THROAT & BRONCHIAL TUBES. LEAD
    COMP'D: ANEMIA, NEUROPATHY, WRIST DROP, KIDNEY DAMAGE, REPRODUCTIVE
    CHANGES.
Explanation of Carcinogenicity:IARC HAS CLASSIFIED " STRONG INORGANIC
    ACID MIST OF SULFURIC ACID" AS A CATEGORY I CARCINOGEN, A SUBSTANCE
    THAT IS CARCINOGENIC TO HUMANS. THIS CLASSIFICATION DOES NOT APPLY
    TO SULFURIC ACID SOLUTIONS	IN STATIC LIQUID STATE OR TO
    ELECTROLYTE IN BATTERIES. LEAD COMP'D LISTED AS 2B IN ANIMALS,
    PROOF IN HUMANS IS LACKING. ARSENIC IS CONSIDERED CARCINOGEN.
Effects of Overexposure:ACUTE: ELECTROLYTE (WATER & SULFURIC ACID
    SOLUTION): SEVERE SKIN IRRITATION, DAMAGE TO CORNEA MAY CAUSE
    BLINDNESS, UPPER RESPIRATORY IRRITATION.  LEAD COMPOUNDS: SYMPTOMS
    OF TOXICITY INCLUDE HEADACHE,  FATIGUE, ABDOMINAL PAIN, LOSS OF
    APPETITE, MUSCULAR ACHES & WEAKNESS, SLEEP DISTURBANCES &
    IRRITABILITY. CHRONIC: ELECTROLYTE (WATER & SULFURIC ACID
    SOLUTION): POSSIBLE EROSION OF TOOTH ENAMEL; INFLA MMATION OF NOSE,
    THROAT & BRONCHIAL TUBES. LEAD COMPOUNDS: ANEMIS; NEUROPATHY,
    PARTICULARLY OF THE MOTOR NERVES, WITH WRIST DROP; KIDNEY DAMAGE;
    REPRODUCTIVE CHANGES IN BOTH MALES & FEMALES.
Medical Cond Aggravated by Exposure:SULFURIC ACID MIST MAY AGGRAVATE
    PULMONARY CONDITIONS,  ELECTROLYTE SOLUTON MAY AGGRAVATE SKIN
    DISEASES SUCH AS ECZEMA AND DERMATITIS. LEAD CAN AGGRAVATE KIDNEY,
    LIVER & NEUROLOGIC DISEASES.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR IMMEDIATELY. IF BREATHING IS
    DIFFICULT, GIVE OXYGEN; CONSULT PHYSICIAN. INGESTION:GIVE LARGE
    QUANTITIES OF WATER; DO NOT INDUCE VOMITING; CONSULT PHYSICIAN.
    SKIN: FLUSH  WITH  WATER FOR AT LEAST 15 MINUTES; REMOVE
    CONTAMINATED CLOTHING  INCLUDING SHOES. EYES: FLUSH WITH  WATER FOR
    AT LEAST 15 MINUTES WITH EYELIDS OPEN. GET MEDICAL HELP.

=====================  Fire Fighting Measures  =====================

Lower Limits:4.1%
Upper Limits:74.2%
Extinguishing Media:CO2; FOAM; DRY CHEMICAL.
Fire Fighting Procedures:USE POSITIVE PRESSURE, SCBA. BEWARE OF ACID
    SPLATTER DURING WATER APPLICATION & WEAR ACID-RESISTANT CLOTHING,
    GLOVES, FACE & EYE PROTECTION. IF BATTERIES ARE ON CHARGE, SHUT OFF
    POWER TO THE CHARGING  EQUIPMENT, BUT, NOTE THAT STRINGS OF SERIES
    CONNECTED BATTERIES MAY STILL POSE RISK OF ELECTRIC SHOCK WHEN
    CHARGING
Unusual Fire/Explosion Hazard:IN OPERATION, BATTERIES GENERATE &
    RELEASE FLAMMABLE HYDROGEN GAS. THEY MUST ALWAYS BE  ASSUMED TO
    CONTAIN THIS GAS WHICH, IF IGNITED BY BURNING CIGARETTE, NAKED
    FLAME OR SPARK, MAY CAUSE BATTERY EXPL OSION WITH DISPERSION OF
    CASING FRAGMENTS & CORROSIVE LIQUID ELECTROLYTE. CAREFULLY FOLLOW
    MANUFACTURER'S INSTRUCTIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP FLOW OF MATERIAL, CONTAIN/ABSORB SMALL
    SPILLS WITH DRY SAND/ EARTH/ VERMICULITE. DO NOT USE COMBUSTIBLE
    MATERIALS. IF POSSIBLE, CAREFULLY NEUTRALIZE SPILLED ELECTROLYTE.
    WEAR ACID-RESISTANT CLOTH ING, BOOTS, GLOVES & FACE SHIELD. DO NOT
    ALLOW DISCHARGE OF UNNEUTRALIZED ACID TO SEWER. NEUTRALIZED ACID
    MUST BE MANAGED I/A/W APPROVED LOCAL, STATE REGULATIONS.
Neutralizing Agent:SODA ASH, SODIUM BICARBONATE, LIME.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE BATTERIES UNDER ROOF IN COOL,
    DRY, WELL-VENTILATED AREAS WHICH ARE SEPARATED FROM INCOMPATIBLE
    MATERIALS & FROM ACTIVITIES WHICH MAY CREATE FLAMES, SPARKS OR
    HEAT. STORE ON SMOOTH, IMPERIVIOUS S URFACES WHICH ARE PROVIDED
    WITH MEASURES FOR LIQUID CONTAINMENT IN THE EVENT OF ELECTROLYTE
    SPILLS.
Other Precautions:THERE IS A POSSIBLE RISK OF ELECTRIC SHOCK FROM
    CHARGING EQUIPMENT & FROM STRINGS OF SERIES CONNECTED BATTERIES,
    WHETHER BEING CHARGED OR NOT. SHUT-OFF POWER TO CHARGERS WHENEVER
    NOT IN USE & BEFORE D ETACHMENT OF ANY CIRCUIT CONNECTIONS.
    BATTERIES BEING CHARGED WILL GENERATE & RELEASE FLAMMABLE HYDR OGEN
    GAS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS. WHEN
    CONCENTRATIONS OF SULFURIC ACID MIST ARE KNOWN TO EXCEED PEL, USE
    NIOSH OR MSHA-APPROVED RESPIRATORY PROTECTION.
Ventilation:STORE AND HANDLE IN WELL-VENTILATED AREA. IF
    MECHANICALVENTILATION IS USED, COMPONENTS MUST BE ACID-RESISTANT.
Protective Gloves:RUBBER OR PLASTIC ACID-RESISTANT GLOVES WITH
    ELBOW-LENGTH GAUNTLET.
Eye Protection:CHEMICAL GOGGLES OR FACE SHIELD.
Other Protective Equipment:ACID-RESISTANT APRON. UNDER SEVERE EXPOSURE
    OR EMERGENCY CONDITIONS, WEAR ACID-RESISTANT CLOTHING, GLOVES AND
    BOOTS.
Work Hygienic Practices:HANDLE BATTERIES CAUTIOUSLY, DO NOT TIP, AVOID
    SPILLS. MAKE CERTAIN VENT CAPS ARE ON SECURELY. AVOID BODILY
    CONTACT WITH INTERNAL COMPONENTS.
Supplemental Safety and Health
IN AREAS WHERE WATER & SULFURIC ACID SOLUTIONS ARE HANDLED IN
    CONCENTRATIONS GREATER THAN 1%, EMERGENCY EYEWASH STATIONS &
    SHOWERS SHOULD BE PROVIDED, WITH UNLIMITED WATER SUPPLY. DO NOT
    OVERCHARGE OR  SHORT CIRCUIT BATTERIES.

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:=95.C, 203.F
B.P. Text:203-240F S.G. RANGE
Vapor Pres:17 TO 11(FOR S.G. RANGE)
Vapor Density:>1(AIR=1)
Spec Gravity:1.230 TO 1.350
Evaporation Rate & Reference:< 1(BUTYL ACETATE=1)
Solubility in Water:100% (ELECTROLYTE)
Appearance and Odor:BATTERY IS A MANUFACTURED ARTICLE; NO APPARENT
    ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
CONTACT WITH COMBUSTIBLES & ORGANIC MATERIALS MAY CAUSE FIRE &
    EXPLOSION. ALSO REACTS VIOLENTLY WITH STRONG REDUCING AGENTS,
    METALS, SULFUR TRIOXIDE GAS, STRONG OXIDIZERS AND WATER. CONTACT
    WITH METALS MAY PRODUCE TOXIC SUL
Stability Condition to Avoid:PROLONGED OVERCHARGE AT HIGH CURRENT;
    SOURCES OF IGNITION.
Hazardous Decomposition Products:SULFUR TRIOXIDE, CARBON MONOXIDE,
    SULFURIC ACID MIST, SULFUR DIOXIDE, HYDROGEN SULFIDE. TEMPERATURES
    ABOVE THE MELTING POINT ARE LIKELY TO PRODUCE TOXIC METAL FUME,
    VAPOR OR DUST.

====================  Disposal Considerations  ====================

Waste Disposal Methods:SPENT BATTERIES; SEND TO SECONDARY LEAD SMELTER
    FOR RECYCLING. ELECTROLYTE: PLACE NEUTRALIZED SLURRY INTO SEALED
    ACID RESISTANT CONTAINERS & DISPOSE OF AS HAZARDOUS WASTE, AS
    APPLICABLE. LARGE WATER-D ILUTED SPILLS, AFTER NEUTRALIZATION &
    TESTING, SHOULD BE MANAGED I/A/W APPROVED LOCAL, STATE & FEDER AL
    REQUIREMENTS.

===================  MSDS Transport Information  ===================

Transport Information:PSN: BATTERY, WET, NON-SPILLABLE, 8, UN2800, III.

=====================  Regulatory Information  =====================

SARA Title III Information:RCRA: SPENT LEAD-ACID BATTERIES ARE NOT
    REGULATED AS HAZARDOUS WASTE WHEN RECYCLED. SPILLED SULFURIC ACID
    IS A CHARACTERISTIC HAZARDOUS WASTE; EPA HAZWASTE #D002
    (CORROSIVITY). CERCLA & EPCRA: RQ FOR  SULFURIC ACID IS 1,000 LB.
    SEC 302: NOTIFICATION REQUIRED IF 1,000 OR MORE OF SULFURIC IS
    PRESENT AT ONE SITE. AVERAGE BATTERY CONTAINS ~5 OF ACID. SEC 313:
    THIS PRODUCT CONTAINS TOXIC CHEMCALS WHICH	MAY BE REPORTABLE (R
    FORM).
Federal Regulatory Information:COMPONENTS OF THESE BATTERIES ARE LISTED
    ON THE TSCA INVENTORY.
State Regulatory Information:CALIFORNIA PROP 65: THIS PRODUCT CONTAINS
    LEAD, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER,
    OR BIRTH DEFECTS OR OTHER REPRODUCTINVE HARM.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
TRIS-GLYCINE GELS:EC-6001;6002;6004;6005 79-06-1
26628-22-8
S07004 SCHENECHEDY RED INSUL. 74-98-6
64742-89-8
108-88-3
100-41-4
1330-20-7
67-64-1
MS-7C BASE COMPONENT, 8010-01-397-3910 25068-38-6
13463-67-7
14807-96-6
37244-96-5
64742-95-6
110-43-0
107-98-2
14808-60-7
MS-7C BASE COMPONENT, 8010-01-397-3987 25068-38-6
13463-67-7
14807-96-6
37244-96-5
64742-95-6
110-43-0
107-98-2
14808-60-7
MS-7C BASE COMPONENT, 8010-01-397-3911 25068-38-6
13463-67-7
14807-96-6
37244-96-5
64742-95-6
110-43-0
107-98-2
14808-60-7
131 2057, KODAK ASSEMBLY CEMENT HE-100X 1330-20-7
TRIS-GLYCINE GELS: 60052;60055;6006;6008 79-06-1
26628-22-8
BREAK-OUT ANTI-SEIZE COMPOUND 64741-96-4
7440-50-8
7002 SATIN FINISH, SPECIALTY SPRAY CLEAR COATINGS & VARNISHE 74-98-6
64742-89-8
100-41-4
1330-20-7
64742-94-5
67-64-1
TRIS-GLYCINE GELS: 60085;6009;6011;6012 79-06-1
26628-22-8
TRI-GLYCINE GELS:6014;6015;60152;60155 79-06-1
26628-22-8
THE PRO FLOORING ADHESIVE TA-0722 8012-95-1
8020-83-5
1332-58-7
14808-60-7
7440-43-9
140-88-5
7439-92-1
1313 SATIN FINISH, INDUSTRIAL MAINTENANCE & TOUCH UP SPRAY 74-98-6
106-97-8
108-88-3
67-64-1
30821 OATEY ALL PURPOSE CEMENT 67-64-1
112945-52-5
68648-82-8
9002-86-2
108-94-1
109-99-9
78-93-3
PROLINE LEMON BEAD WAX 9016-45-9
111-76-2
TRI-GLYCINE GELS:6016;6018;60185;6019 79-06-1
26628-22-8
TRI-GLYCINE GELS:6021;6022;6024;6025 79-06-1
26628-22-8
ELECTRON TUBE BTR-229 7440-48-4
TRI-GLYCINE GELS:60252;60255;6026;6028 79-06-1
26628-22-8
P/N: 371491-01493, CORAY 46 64742-52-5
TRI-GLYCINE GELS:60285;6029;6035;60352 79-06-1
26628-22-8
178 7720, KODAK OPTICAL CEMENT, HES-1 97-88-1
94-36-0
TRI-GLYCINE GELS:60355;6036;6038;60385 79-06-1
26628-22-8
PROTINOL PROTEIN-BASED CONTROLS 3MA028
LIQUID NEUTRALIZER 1310-73-2
LEAD-ACID BATTERY (ELECTRIC STORAGE BATTERY) 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
7664-93-9
9003-07-0
60676-86-0
568, 48% NICKEL CARBONATE POWDER 3333-67-3
1750 DRAMATONE COLORANT-NEUTRAL TONER N-T 107-21-1
127087-87-0
12713-03-0
1332-58-7
1333-86-4
7439-96-5
14808-60-7
1309-37-1
50-00-0
8002-43-5
7732-18-5
51274-00-1
NITROGEN TRIFLUORIDE 7783-54-2
JELTRATE PLUS 68855-54-9
7722-88-5
GENERATION 2000* GEN-AIR DUSTER, E1027 75-37-6
POTASSIUM CHLORATE, ACS 3811-04-9
DAMP PROOF RED PRIMER 769 8052-41-3
64742-88-7
14807-96-6
108-67-8
95-63-6
136-52-7
68071-87-4
59794-15-9
1309-37-1
SODIUM HYDROXIDE, 0.02 TO 0.1 NORMAL VOLUMETRIC SOLUTIONS 1310-73-2
NON-FLAMMABLE GAS MIXTURE 50009 7782-44-7
74-82-8
1333-74-0
630-08-0
7727-37-9
NEAT STAIN SOLUTION II, 5303, 5316, 5319, 5330 & SP851-25 7220-79-3
7778-77-0
10049-21-5
188 7546,KODAK T-552 DEVELOPER,SOLUTION NO. 1 7732-18-5
584-08-7
111-42-2
497-19-8
1310-58-3
NEAT STAIN FIXATIVE, 5303, 5316, 5317 & SP851-25 2353-45-9
67-56-1
SODIUM BICHROMATE CRYSTAL 10588-01-9
7732-18-5
TRIS- GLYCINE GELS: 6039;6041;6042;6044 79-06-1
26628-22-8
TRIS-GYLCINE GELS:6045;60452;60455;6046 79-06-1
26628-22-8
132 6503, KODAK C-10 CLEANING MATERIAL 7439-89-6
24937-79-9
TRIS-GLYCINE GELS: 6048;60485;6049;6055 79-06-1
26628-22-8
CESIUM (I) NITRATE 7789-18-6
SODIUM NITROFERRICYANIDE 13755-38-9
VAPO-STERIL SOLUTION 50-00-0
COMPRESSOR OIL 10, 20, 30W 64742-65-0
54200-00045, AUSTIN A-1 BLEACH 7681-52-9
1310-73-2
132-12 64742-34-3
64742-11-6
FM 275 ADHESIVE FILM

Free MSDS Search ( Providing 250,000+ Material Properties )