===================== Product Identification =====================
MSDS NAME:199 7873,KODAK VERSA, 885 FIXER & REP. PART B, (SEE SUPPL)
NIIN:01-353-4888
Status Code:A
Kit Part:Y
MSDS Number: CLKCX
=== Responsible Party ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Info Phone Num:716-722-5151/(800) 242-2424
Emergency Phone Num:716-722-5151
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
============= Composition/Information on Ingredients =============
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Minumum % Wt:75.
Maxumum % Wt:80.
Name:ALUMINUM SULFATE
CAS:10043-01-3
RTECS #:BD1700000
Minumum % Wt:20.
Maxumum % Wt:25.
ACGIH TLV:2 MG/M3 AL SOL SALT
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT): NOT GIVEN
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:GENERAL: CONTAINS ALUMINUM SULFATE.
INGESTION MAY CAUSE NAUSEA, VOMITING, ABDOMINAL PAINS, AND
DIARRHEA. INHALATION: EXPECTED TO BE A LOW HAZARD FOR USUAL
INDUSTRIAL OR COMMERCIAL HANDLING BY TRAINED PERSONNEL. EYES:
CAUSES IRRITATION. SKIN: CAUSES IRRITATION. INGESTION: MAY BE
HARMFUL IF SWALLOWED.
Explanation of Carcinogenicity:CARCINOGENICITY CLASSIFICATION
(COMPONENTS PRESENT AT 0.1% OR MORE): IARC: NONE. ACGIH: NONE. NTP:
NONE. OSHA: NONE.
Effects of Overexposure:EYES: IRRITATION. INHALATION: LOW HAZARD. SKIN:
IRRITATION. INGESTION: NAUSEA, VOMITING, ABDOMINAL PAINS, AND
DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. TREAT
SYMPTOMICALLY. GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. EYES:
FLUSH IMMEDIATELY WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTI ON. SKIN: REMOVE CONTAMINATED CLOTHING AND SHOES
AND WASH WITH SOAP AND WATER. GET MEDICAL ATTENTION IF SYMPTOMS
OCCUR. WASH CONTAMINATED CLOTHING BEFORE REUSE. DESTROY OR
THOROUGHLY CLEAN CONTAMINATE D SHOES. INGESTION: DRINK 1-2 GLASSES
OF WATER. SEEK MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO
AN UNCONSCIOUS PERSON.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS. HAZARDOUS COMBUSTION PRODUCTS: NONE
(NONCOMBUSTIBLE).
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:FLUSH TO SEWER IF ALLOWABLE WITH LARGE AMOUNTS
OF WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN
SURFACE TO REMOVE RESIDUA L CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PERSONAL PRECAUTIONARY MEASURES: AVOID
BREATHING MIST OR VAPOR. AVOID CONTACT WITH EYES, SKIN, AND
CLOTHING. USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING. PREVENTION OF FIRE AND EXPLO SION: NO SPECIAL
PRECAUTIONARY MEASURES SHOULD BE NEEDED UNDER ANTICIPATED
CONDITIONS OF USE.
Other Precautions:STORAGE: KEEP CONTAINER CLOSED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION, TYPICALLY 10 AIR CHANGES PER
HOUR, SHOULD BE USED. RATES SHOULD MATCH CONDITIONS.
Protective Gloves:IMPERVIOUS
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS OR GOGGLES.
Other Protective Equipment:SKIN PROTECTION: WEAR IMPERVIOUS GLOVES AND
PROTECTIVE CLOTHING APPROPRIATE FOR THE RISK OF EXPOSURE. PROVIDE
EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:REMOVE AND WASH CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
THIS ENTRY DESCRIBES PART B, MSDS SERIAL NUMBER (CLKCX) IN THE "KODAK
VERSAMAT 885 FIXER AND REPLENISHER KIT" A THREE PART KIT. SEE THIS
SAME NSN, MSDS SERIAL NUMBER (CLKCK) FOR PART A OF KIT AND MSDS
SERIAL NUMBER (CLJZB) FOR REPLENISHER SOLUTION PART OF KIT.
================== Physical/Chemical Properties ==================
HCC:C1
Boiling Pt:>100.C, 212.F
Vapor Pres:24 MBAR, 18 MM HG @ 20C
Vapor Density:0.6 (AIR=1
Spec Gravity:1.30 (WATER=1)
pH:2.3
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, NO ODOR.
Percent Volatiles by Volume:75-80% WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFUR DIOXIDE.
=================== Toxicological Information ===================
Toxicological Information:GENERAL: CONTAINS ALUMINUM SULFATE. INGESTION
MAY CAUSE NAUSEA, VOMITING, ABDOMINAL PAINS, AND DIARRHEA.,
===================== Ecological Information =====================
Ecological:THE FOLLOWING PROPERTIES ARE ESTIMATED FROM THE COMPONENTS
OF THE PREPARATIONS. POTENTIAL TOXICITY: FISH, LC50: >100 MG/L;
DAPHNID, EC50: >100 MG/L; ALGAL, IC50: >100 MG/L. ORGANICS READILY
DEGRADABLE (>70%): NOT APPLICABLE. POTENTIAL BIOACCUMULATION: LOG
POW <1. COD (APPROXIMATE): 0 G/L. BOD5 (APPROXIMATE): 0 G/L.
POTENTIAL TOXICITY:WASTE TREATMENT MICROOGANISMS EC50: >100 MG/L.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. SINCE EMPTIED CONTAINERS RETAIN
PRODUCT RESIDUE, FOLLOW LABEL WARNINGS EVEN AFTER CONTAINER IS
EMPTIED.
=================== MSDS Transport Information ===================
Transport Information:TRANSPORTATION DATA PER KODAK PHONE NUMBER
716-722-9163: CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S.,
(ALUMINUM SULFATE), 8, UN 3264, I I I.
===================== Regulatory Information =====================
SARA Title III Information:CHEMICALS SUBJECT TO THE REPORTING
REQUIREMENTS OF SECTION 313 OF TITLE I I I OF THE SUPERFUND
AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 AND 40 CFR PART
372: NONE.
State Regulatory Information:MATERIALS KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER: NONE. MATERIALS KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE ADVERSE REPRODUCTIVE EFFECTS: NONE.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|