===================== Product Identification =====================
MSDS NAME:BLEND-A-COLOR TONERS, 744-1002 BLACK
NIIN:00-598-9156
Status Code:A
MSDS Number: CLRQM
=== Responsible Party ===
Company:SHERWIN-WILLIAMS CO THE
Address:101 PROSPECT AVE NW
City:CLEVELAND
State:OH
ZIP:44115-1042
Country:US
Info Phone Num:800-251-2486/216-566-2242
Emergency Phone Num:216-566-2917
Preparer's Name:ERNEST CARTER
Chemtrec Ind/Phone:(800)424-9300
CAGE:54636
=== Contractor Identification ===
Company:SHERWIN-WILLIAMS CO THE
Address:101 PROSPECT AVE NW
Box:City:CLEVELAND
State:OH
ZIP:44115-1042
Country:US
Phone:800-251-2486/216-566-2242
CAGE:54636
============= Composition/Information on Ingredients =============
Name:OCTYLPHENOXYPOLY(ETHOXYETHANOL)
CAS:9036-19-5
RTECS #:MD0907600
= Wt:18.
Name:ETHYLENE GLYCOL
CAS:107-21-1
RTECS #:KW2975000
= Wt:24.
ACGIH STEL:C127 MG/M3;C50 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:KAOLS
CAS:1837-58-7
= Wt:18.
Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3
Name:CARBON BLACK
= Wt:8.
Name:TALC
CAS:14807-98-8
= Wt:11.
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Health Hazards Acute and Chronic:EXPOSURE MAY BE BY INHALATION AND/OR
SKIN OR EYE CONTACT, DEPENDING ON CONDITIONS OF USE. TO MINIMIZE
EXPOSURE, FOLLOW RECOMMENDATIONS FOR PROPER MSDS, VENTILATION, AND
PERSONAL PROTECTIVE EQUIPMENT.
Effects of Overexposure:IRRITATION OF EYES, SKIN AND UPPER RESPIRATORY
SYSTEM, IN A CONFINED AREA VAPORS IN HIGH CONCENTRATION MAY CAUSE
HEADACHE, NAUSEA OR DIZZINESS. REDNESS AND ITCHING OR BURNING
SENSATION MAY INDICATE EY E OR EXCESSIVE SKIN EXPOSURE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
======================= First Aid Measures =======================
First Aid:IF INHALED: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING, KEEP WARM AND QUIET. IF ON SKIN: WASH AFFECTED AREA
THOROUGHLY WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND
LAUNDER BEFORE RE -USE. IF IN EYES: FLUSH EYES WITH LARGE AMOUNTS
OF WATER FOR 15 MINUTES. GET MEDICAL ATTENTION. IF SWALLOWED: NEVER
GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. GIVE CONSCIOUS
PATIENT SEVERAL GLAS SES OF WATER. IF VOMITING IS NOT SPONTANEOUS,
INDUCE VOMITING BY HAVING THE PATIENT GENTLY TOUCH THE BACK OF HIS
THROAT WITH A FINGER. KEEP AIRWAY CLEAR. SEEK MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:=111.1C, 232.F
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM.
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT INCLUDING SELF
CONTAINED BREATHING APPARATUS SHOULD BE USED. WATER SPRAY MAY BE
INEFFECTIVE, IF WATER IS USED, FOG NOZZLES ARE PREFERABLE. WATER
MAY BE USED TO COOL CLOSED CO NTAINERS TO PREVENT PRESSURE BUILD UP
AND POSSIBLE AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME
HEAT.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILD UP OF PRESSURE WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
TRANSFER ONLY TO EXPOSED CONTAINERS WITH COMPLETE AND APPROPRIATE
LABELING, DO NOT TAKE INTERNALLY. KEEP OUT OF THE REACH OF
CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA FOR PROTECTION
AGAINST MATERIALS IN SECTION 2. WHEN SANDING OR ABRADING THE DRIED
FILM, WEAR A DUST/MIST RESPIRATOR APPROVED BY NIOSH/MSHA FOR DUST
WHICH MAY BE GENERATED FROM THIS PRODUCT, UNDER
Ventilation:LOCAL EXHAUST PREFERABLE, GENERAL EXHAUST ACCEPTABLE IF THE
EXPOSURE TO MATERIALS IN SECTION 2 IS MAINTAINED BELOW APPLICABLE
EXPOSURE LIMITS.
Protective Gloves:WEAR GLOVES WHICH ARE RECOMMENDED BY SUPPLIER FOR
PROTECTION AGAINST MATERIALS
Eye Protection:WEAR SAFETY SPECTACLES WITH UNDERFORATED SIDESHIELDS.
Work Hygienic Practices:USE ONLY WITH ADEQUATE VENTILATION. AVOID
BREATHING VAPOR AND SPRAY MIST. AVOID CONTACT WITH SKIN AND EYES.
WASH HANDS AFTER USING.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:312-385 DEG F
Vapor Density:HEAVIER
Spec Gravity:1.32-2.23
pH:6.3
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:25-62%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE FROM THESE PRODUCTS IS NOT HAZARDOUS AS
DEFINED UNDER THE RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) 40
CFR 261. INCINERATE IN APPROVED FACILITY. DO NOT INCINERATE CLOSED
CONTAINER. DISPOSE O F IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS REGARDING POLLUTION.
===================== Regulatory Information =====================
State Regulatory Information:CALIFORNIA PROPOSITION 65: WARNING ! AGAW
1 CONTAINS
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER. AGUH 1, AGDY 1 AND AGOY) CONTAIN
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE C ANCER. ASOB, ASDO1, A68L1, A68F1, AND A60 RZ
CONTAIN CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR
OTHER REPRODUCTIVE HARM.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|