===================== Product Identification =====================
MSDS NAME:COOLANOL 25R DIELECTRIC HEAT TRANSFER FLUID
NIIN:01-015-1539
MSDS Number: BGDMG
=== Responsible Party ===
Company:MONSANTO CO
Address:800 N. LINDBERGH BLVD
City:ST. LOUIS
State:MO
ZIP:63167
Info Phone Num:314-694-1000
Emergency Phone Num:314-694-1000
CAGE:76541
=== Contractor Identification ===
Company:MONSANTO COMPANY
Address:800 N LINDBERGH BLVD
Box:City:SAINT LOUIS
State:MO
ZIP:63167
Country:US
Phone:314-694-6661 OR 800-332-3111
CAGE:76541
============= Composition/Information on Ingredients =============
Name:ORGANO-SILICATE ESTER
Name:ANTIOXIDANT ADDITIVE (PROPRIETARY)
Name:2,6-DI-TERT-BUTYL-P-CRESOL
CAS:128-37-0
RTECS #:GO7875000
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3; 9192
Name:BERYLLIUM SILICATE (AS BERYLLIUM)
CAS:15191-85-2
RTECS #:VV8925000
Other REC Limits:OSHA CEILING 0.005
OSHA PEL:0.002 MG/M3; C,0.005
ACGIH TLV:0.002 MG/M3; A2;8990
Name:HYDROGEN CHLORIDE (HYDROCHLORIC ACID) (SARA III)
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: TRACE
OSHA PEL:C 5 PPM
ACGIH TLV:C 5 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL RAT LD50 > 15800 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:COOLANOL 25R IS NOT EXPECTED TO
PRODUCE ADVERSE HUMAN HEALTH EFFECTS WHEN RECOMMENDED SAFETY
PRECAUTIONS. PRODUCT IS A MILD IRRITANT.
Explanation of Carcinogenicity:HMTC LETTER OF 5DEC84 LISTED INGRED. 04
AS "ORTHO SILICATE". CAS NO. IS FOR BERYLLIUM SILICATE,A LISTED
CARCINOGEN.
Effects of Overexposure:EYE/SKIN:MILD IRRITATION. INHALED:RESPIRATORY
IRRITATION.
Medical Cond Aggravated by Exposure:NONE REPORTED.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER. SKIN:REMOVE CONTAMINATED CLOTHING,WASH
WITH SOAP & WATER. INHALED:REMOVE TO FRESH AIR. INGESTED:GIVE LARGE
AMOUNT OF MILK OR WATER. GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:325F/163C
Autoignition Temp:Autoignition Temp Text:480F
Extinguishing Media:WATER SPRAY,FOAM,DRY CHEMICAL,CARBON DIOXIDE OR
OTHER AGENT FOR CLASS B FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND SELF
CONTAINED BREATHING APPARATUS. DECONTAMINATE EQUIPMENT AFTER USE.
Unusual Fire/Explosion Hazard:SEE HAZARDOUS DECOMPOSITION PRODUCTS.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB ON INERT MATERIAL.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE TIGHTLY CLOSED IN A COOL DRY
AREA.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY NEEDED. USE NIOSH ORGANIC VAPOR
RESPIRATOR OR SUPPLIED AIR RESPIRATOR IF PRODUCT IS USED AT
ELEVATED TEMPERATURES OR IS MISTED.
Ventilation:GENERAL VENTILATION NORMALLY SUFFICIENT. USE LOCAL EXHAUST
FOR HIGH EXPOSURE OPERATIONS
Protective Gloves:WEAR PROTECTIVE (RUBBER) GLOVES.
Eye Protection:MFR:NONE HMIS:SAFETY GLASSES.
Work Hygienic Practices:USE NORMAL,GOOD INDUSTRIAL HYGIENE PRACTICE,
AVOIDING UNNECESSARY CONTACT AND REMOVING MTL FROM
SKIN,EYES,CLOTHING.
Supplemental Safety and Health
INGREDIENTS FROM LETTER TO HMTC 05DEC84.MFR DOES NOT CONFIRM OR DENY
USE OF BERYLLIUM SILICATE(1988). SEE DGSC-SLM CASE HISTORY 85089H
FOR DETAILS.
================== Physical/Chemical Properties ==================
HCC:N1
Vapor Pres:<0.001PSIA
Vapor Density:16
Spec Gravity:0.893-0.900
Solubility in Water:VERY LOW
Appearance and Odor:CLEAR LIQUID,MILD SWEET ODOR * POUR POINT <-90F/68C
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER AT ELEVATED TEMPERATURES,STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:MOISTURE.
Hazardous Decomposition Products:NORMAL PRODUCTS OF HYDROCARBON
COMBUSTION,SILICA.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
MFR SUGGESTS INCINERATION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|