===================== Product Identification =====================
MSDS NAME:VP-30 PENETRANT(PRE 10/86) NSN CANCELLED
NIIN:01-019-0668
MSDS Number: BGDWX
=== Responsible Party ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID STREET
City:SANTA MONICA
State:CA
ZIP:90404-3770
Country:US
Info Phone Num:213-450-1111
Emergency Phone Num:213-450-1111
CAGE:98733
=== Contractor Identification ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID ST
Box:00000
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Phone:310-450-1111/FAX 310452-4046
CAGE:98733
============= Composition/Information on Ingredients =============
Name:PETROLEUM HYDROCARBON
Fraction by Wt: 100%
Other REC Limits:200 PPM
ACGIH TLV:200 PPM
===================== Hazards Identification =====================
Effects of Overexposure:IRRITATION OF RESPIR.TRACT.CENTRAL NERVOUS
SYSTEM STIM.FOLLOWED BY DEPRESSION OF VARYING DEGREES.
======================= First Aid Measures =======================
First Aid:INHALATION:REMOVE TO FRESH AIR, MAINTAIN RESPIRATION.
EYES:WASH WITH PLENTY OF WATER. SKIN:REMOVE BY WIPING, WASH WITH
SOAP & WATER.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:144F/62.2C
Extinguishing Media:FOAM,CO*2,DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE SOURCES OF IGNITION. AVOID PROLONGED
BREATHING OF VAPORS. AVOID CONTACT WITH SKIN & EYES. MAY BE FLUSHED
WITH WATER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE BELOW 120F & OUT OF DIRECT RAYS
OF SUN. DO NOT EXPOSE TO FIRE.
Other Precautions:KEEP CONTAINERS CLOSED & CLEARLY LABELED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE
Ventilation:LOCAL EXHAUST OR MECHANICAL
Protective Gloves:NONE
Other Protective Equipment:NONE
Supplemental Safety and Health
NSN WAS GROUP III OF MIL-I-25135,REV "C" PER QPL-25135-13,VP-30
PENETRANT WAS OF GROUP III; AFTER THE MIL SPEC WAS REVISED,ACTION
WAS INITIATED TO CANCEL THE NSN AS DUPLICATE OF 6850-01-267-7989.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:350F/176.6C
Vapor Pres:2.0
Vapor Density:4.0
Spec Gravity:0.8
Evaporation Rate & Reference:1.0, ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:DEEP RED LIQUID, PLEASANT, OILY ODOR
Percent Volatiles by Volume:75.0
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:KEEP AWAY FROM SPARKS & OPEN FLAMES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION WILL RELEASE CO.
==================== Disposal Considerations ====================
Waste Disposal Methods:HAUL AWAY FOR SAFE OUTDOOR DISPOSAL, OR HAUL
AWAY BY OIL RECLAIMERS OR BURN IN AN INCINERATOR OR UNDER APPROVED
CONTROLLED CONDITIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|