===================== Product Identification =====================
MSDS NAME:PC-18 STD URETHANE VARNISH
NIIN:01-102-8158
MSDS Number: BGLXK
=== Responsible Party ===
Company:THE DEXTER CORP. DEXTER ELECTRONIC MATERIALS DIV.
Address:211 FRANKLIN ST.
City:OLEAN
State:NY
ZIP:14760-1297
Country:US
Info Phone Num:716-372-6300
Emergency Phone Num:716-372-6309
Preparer's Name:JAMES P. HORNBURG
CAGE:DO846
=== Contractor Identification ===
Company:DEXTER CORP THE DEXTER ELECTRONIC MATERIAL DIV
Address:211 FRANKLIN ST.
Box:City:OLEAN
State:NY
ZIP:14760-1297
Country:US
Phone:716-372-6300/6309
CAGE:04347
Company:MCKEOWN ROBERT CO. INC.
Address:111 CHAMBERS BROOK RD.
Box:City:SOMERVILLE
State:NJ
ZIP:08876
Country:US
Phone:908-218-9000
CAGE:7B953
Company:THE DEXTER CORP. WATER MANAGEMENT SYSTEMS DIVISION
Box:200
City:CHAGRIN FALLS
State:OH
ZIP:44022
Country:US
Phone:216-247-5000
CAGE:DO846
============= Composition/Information on Ingredients =============
Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 15-20%
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:PROPYLENE GLYCOL METHYL ETHER ACETATE
CAS:108-65-6
RTECS #:AI8295000
Fraction by Wt: 10-30%
Name:ETHYL BENZENE (SARA III)
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: 5-10%
OSHA PEL:100 PPM/125 STEL
ACGIH TLV:100 PPM/125STEL 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:URETHANE PREPOLYMER (MAY CONTAIN A SMALL AMOUNT OF
UNREACTED OR FREE TOLUENE DI-ISOCYANATE.) (STEL 0.02 PPM TDI)
Fraction by Wt: 30-60%
OSHA PEL:0.005 PPM TDI
ACGIH TLV:0.005 PPM TDI
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:LIQUID MAY BE SEVERELY IRRITATING TO
BODY TISSUES. TOLUENE DIISOCYANATE MAY SENSITIZE ALLERGIC
REACTIONS. SOLVENTS ARE ABSORBED BY THE SKIN AND WITH CHRONIC
OVEREXPOSURE MAY CAUSE PERMANENT CENTRAL NE RVOUS SYSTEM DAMAGE
KNOWN AS PAINTERS SYNDROME. THE AMOUNT OF FREE TDI VARRIES WITH LOT
AND IS OFTEN NEGLIGIBLE
Explanation of Carcinogenicity:TOLUENE DIISOCYANATE IS LISTED BY NTP
AND IARC. SEE INDIVIDUAL REPORTS FOR DETAILS. AMT OF FREE TDI IS
OFTEN NEGLIGIBLE
Effects of Overexposure:EYE: SEVERE IRRITATION. SKIN:IRRITATION,
DERMATITIS, SENSITIZED DERMATITIS. INHALED:RESPIRATORY IRRITATION,
FLU-LIKE SYMPTOMS, ASTHMA, SENSITIZING, NARCOSIS, LOSS OF APPETITE.
INGESTED:G/I IRRITATION, HEADACHE,NAUSEA,VOMITING,DIARRHEA.
Medical Cond Aggravated by Exposure:PEOPLE WITH DERMATITIS, ASTHMA, AND
OTHER SIMILAR DISORDERS SUCH AS EMPHYSEMA, ECZEMA, TDI SENSIVITY,
ETC. MAY BE AT INCREASED RISK.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/ WATER 15 MIN HOLD LIDS OPEN. SEE A DOCTOR.
SKIN:REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE WASH
WITH SOAP & WATER. INHALED:REMOVE TO FRESH AIR. GIVE OXYGEN OR
ARTIFICIAL RES PIRATION AS NEEDED. GET MEDICAL CARE ASASTHMATIC
SYMPTOMS MAY DEVELOP EITHER IMMEDIATELY OR DELAYED SEVERAL HOURS.
INGESTED:DO NOT INDUCE VOMITING. GIVE WATER TO DRINK IF CONSCIOUS.
GET MEDICAL CARE.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:88.0F,31.1C
Lower Limits:1.0 XYLENE
Upper Limits:7.0 XYLENE
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG. (WATER SPRAY MAY BE INEFFECTIVE.)
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
================== Accidental Release Measures ==================
Spill Release Procedures:USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.
COVER SPILL WITH SAWDUST,VERMICULITE,ETC. ADD LIQUID DECONTAMINANT
AND ALLOW TO SET FOR AT LEAST 10 MIN. COLLECT MATERIAL IN OPEN
CONTAINERS AND ADD MO RE DECONTAMINANT.
Neutralizing Agent:WATER WITH 2-5% DETERGENT AND 0-10% AMMONIA. SEE
SUPP DATA FOR ALTERNATE.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE TIGHTLY CLOSED IN A DRY AREA,
FOR FLAMMABLE MATERIALS. APPLY ALL SAFETY PRECAUTIONS TO EMPTY AS
WELL AS FULL CONTAINERS.
Other Precautions:PROTECT FROM MOISTURE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR WHEN SPRAYING
OR WHENEVER EXPOSED TO VAPORS/FUMES NEAR OR ABOVE PEL/TLV. FRESH
AIR RESPIRATOR IS RECOMMENDED OVER CANISTER TYPE.
Ventilation:GENERAL VENTILATION SUPPLEMENTED WITH LOCAL EXHAUST, AS
NEEDED TO MAINTAIN EXPOSURES BELOW PEL/TLV.
Protective Gloves:RUBBER,VINYL OR OTHER IMPERVIOUS
Eye Protection:GOGGLES OR FACE SHIELD **NO CONTACTS!!*
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICES. AVOID
CONTACT IF POSSIBLE. WASH THOROUGHLY AFTER USING.
Supplemental Safety and Health
ALTERNATE DECONTAMINANT: 20% TERGITOL TMN-10 IN WATER. B.P., F.P. ARE
FOR THE SOLVENT PORTION OF THE VARNISH.
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:275F,135C*
Vapor Pres:9.5 MM
Vapor Density:3.7
Spec Gravity:1.02
Evaporation Rate & Reference:0.54(N-BUTYL ACETATE + 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIGHT AMBER MEDIUM VISCOSITY LIQUID, AROMATIC ESTER
SOLVENT ODOR
Percent Volatiles by Volume:58
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE REPORTED BY MFR
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
TRACES ON HYDROGEN CYANIDE, OXIDES OF NITROGEN
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|