===================== Product Identification =====================
MSDS NAME:LEAD-ACID BATTERY
NIIN:01-102-1642
MSDS Number: BGLWT
=== Responsible Party ===
Company:EXIDE CORP
Address:645 PENN STREET
City:READING
State:PA
ZIP:19612-4205
Country:US
Info Phone Num:215-378-0500/0757 FAX -0616
Emergency Phone Num:215-378-0527/800-424-9300(CHEMTREC)
CAGE:20038
=== Contractor Identification ===
Company:BATTERY OUTLET INC
Address:1608 CAMPOSTELLA RD
Box:City:CHESAPEAKE
State:VA
ZIP:23324
Country:US
Phone:757-545-4442
CAGE:0FGN2
Company:BATTERY OUTLET OF HAMPTON INC
Address:2815 GEORGE WASHINGTON HWY
Box:City:TABB
State:VA
ZIP:23602
Country:US
Phone:804-867-8280
CAGE:0FTM0
Company:COLONIAL TRUCK SALES INC
Address:1833 COMMERCE RD
Box:City:RICHMOND
State:VA
ZIP:23224-7801
Country:US
Phone:804-232-3492
CAGE:5A850
Company:EXIDE CORP
Address:645 PENN STREET
Box:14205
City:READING
State:PA
ZIP:19612-4205
Country:US
Phone:610-378-0500/0798
CAGE:20038
Company:MEGATRON SUPPLY CO INC
Address:1016 NANDINO BLVD
Box:11578
City:LEXINGTON
State:KY
ZIP:40576-1578
Country:US
Phone:606-231-1016
CAGE:0TAW6
============= Composition/Information on Ingredients =============
Name:LEAD (SARA III)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 60%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.05 MG/M3;1910.1025
ACGIH TLV:0.15 MG/M3;DUST 9293
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:ANTIMONY (SARA III)
CAS:7440-36-0
RTECS #:CC4025000
Fraction by Wt: 2%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG SB/M3; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:ARSENIC (SARA III)
CAS:7440-38-2
RTECS #:CG0525000
Fraction by Wt: 0.2%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 MG/M3 (AS)
ACGIH TLV:0.01,A1 MG/M3; 9394
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:CALCIUM, METAL
CAS:7440-70-2
RTECS #:EV8040000
Fraction by Wt: 0.2%
Other REC Limits:NONE RECOMMENDED
Name:TIN
CAS:7440-31-5
RTECS #:XP7320000
Fraction by Wt: 0.2%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3; 9293
Name:SULFURIC ACID (SARA III)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 10 - 30%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:CASE MATERIAL (POLYPROPYLENE, POLYSTYRENE...)
Fraction by Wt: 5 - 10%
Other REC Limits:NONE RECOMMENDED
Name:OTHER COMPONENTS (SILICONE DIOXIDE OR SHEET MOLDING)
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE-LEAD MAY CAUSE GI UPSET,LOSS OF
APPETITE,DIARRHEA,CONSTIPATION,CRAMPING,LACK OF SLEEP &
FATIGUE.CONTACT WITH SULFURIC ACID MAY LEAD TO EYE,SKIN &
RESPIRATORY TRACT IRRITATION,CORNEAL & LUNG DAMA GE.CHRONIC-LEAD
MAY CAUSE ANEMIA,KIDNEY& NERVOUS SYSTEM DAMAGE.ACID CAN CAUSE
BRONCHITIS,EROSION OF TOOTH ENAMEL.
Explanation of Carcinogenicity:LEAD AND ARSENIC ARE POSSIBLY
CARCINOGENIC TO HUMAN (MSDS).
Effects of Overexposure:LEAD MAY CAUSE GI UPSET, LOSS OF APPETITE,
DIARRHEA, CONSTIPATION, CRAMPING, LACK OF SLEEP & FATIGUE. CONTACT
WITH SULFURIC ACID MAY LEAD TO EYE, SKIN & RESPIRATORY TRACT
IRRITATION, CORNEAL & LUNG DA MAGE.
Medical Cond Aggravated by Exposure:EXPOSURE TO SULFURIC ACID MIST MAY
AGGRAVATE PULMONARY CONDITIONS AND SKIN DISEASES SUCH AS ECZEMA AND
CONTACT DERMATITIS. LEAD AND ITS COMPOUNDS CAN AGGRAVATE KIDNEY,
LIVER & NEUROLOGIC DISEASES.
======================= First Aid Measures =======================
First Aid:OBTAIN MEDICAL ATTENTION IN ALL CASES OF EXPOSURE.
EYES/SKIN:FLUSH WITH WATER FOR 15 MINUTES. KEEP EYELIDS OPEN.
INHALED:MOVE TO FRESH AIR. ORAL:DO NOT INDUCE VOMITING. CALL
PHYSICIAN IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Lower Limits:4.1%HYDROGEN
Upper Limits:74.2%
Extinguishing Media:DRY CHEMICAL, FOAM, CO2, HALOGEN
Fire Fighting Procedures:IF BATTERIES ARE ON CHARGE, SHUT OFF POWER.
USE POSITIVE PRESSURE, SELF-CONTAINED BREATHING APPARATUS. WATER
APPLIED TO ELECTROLYTE GENERATE HEAT. AVOID IT.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE HYDROGEN GAS IS
GENERATED DURING CHARGING & OPERATION OF BATTERIES. KEEP
SPARKS/OTHER SOURCES OF IGNITION AWAY. DO NOT SHORT BATTERIES.
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID CONTACT WITH SULFURIC ACID ELECTROLYTE
FROM BATTERY. LIME OR SODA MAY BE USED TO NEUTRALIZE AFTER DILUTING
WITH WATER. CONTAIN LARGER SPILLS WITH SAWDUST OR OTHER ABSORBING
MATERIAL. WEAR ACID R ESISTANT GLOVES AND OTHER PROTECTIVE
CLOTHING.
Neutralizing Agent:SODIUM BICARBONATE SOLUTION (1 LB TO 1 GAL
WATER)-LIME OR SODA ASH
====================== Handling and Storage ======================
Handling and Storage Precautions:STORAGE- STORE IN COOL, DRY, WELL
VENTILATED AREA AWAY FROM FIRE, SPARKS & HEAT. STORE ONLY IN AREAS
WITH ADEQUATE WATER SUPPLY & SPILL CONTROL.
Other Precautions:KEEP TERMINALS COVERED IN PLASTIC CASE. AVOID
SHORTING BATTERIES. DO NOT CRACK OR OVERCHARGE BATTERIES. KEEP
LIGHTED CIGARETTES, SPARKS, AND FLAMES AWAY FROM CHARGING
BATTERIES. KEEP OUT OF REACH OF C HILDREN. AVOID DAMAGE TO
CONTAINERS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT REQUIRED UNDER NORMAL USE. USE
NIOSH-APPROVED ACID-MIST FILTER RESPIRATOR IF 1 MG/M3 TWA IS
EXCEEDED (ACID).
Ventilation:ADEQUATE GENERAL VENTILATION
Protective Gloves:RUBBER
Eye Protection:SPLASH-PROOF CHEMICAL GOGGLES
Other Protective Equipment:RUBBER APRON AND BOOTS. EYES WASH STATION
AND SAFETY SHOWER. USE ACID-PROOF CLOTHING FOR MAJOR SPILLS.
Work Hygienic Practices:REMOVE METALLIC JEWELRY-SHOCK POTENTIAL. WASH
THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:203F,95C
Vapor Pres:10
Vapor Density:>1
Spec Gravity:1.230 - 1.350
pH:<1
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:100% (ELECTROLYTE)
Appearance and Odor:MANUFACTURED ARTICLE; NO APPARENT ODOR.
ELECTROLYTE:CLEAR LIQUID-PUNGENT ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
COMBUSTIBLES, ORGANIC MATERIALS, STRONG REDUCING AGENTS, MOST METALS,
STRONG OXIDIZERS, WATER, BASES, HALIDES
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES, OVERCHARGING,
SMOKING, SPARKS
Hazardous Decomposition Products:OXIDES OF LEAD AND SULFUR, HYDROGEN,
CARBON MONOXIDE, HIGHLY TOXIC ARSINE GAS, SULFURIC ACID MIST
==================== Disposal Considerations ====================
Waste Disposal Methods:PLACE NEUTRALIZED SLURRY INTO SEALED CONTAINERS
AND DISPOSE OF AS HAZARDOUS WASTE, IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL ENVIRONMENTAL REGULATIONS FOR ACID OR LEAD SCRAP.
SEND SPENT BATTERIES TO SECONDARY LEAD SMELTER FOR RECYCLING.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|