Search   
MSDS  
:
 FLAW-FINDER AG-1-VS PENETRANT
CAS  
:
 115-86-6
75-71-8
NAME  
:
 triphenyl phosphate
dichlorodifluoromethane (sara iii)
=====================  Product Identification  =====================

MSDS NAME:FLAW-FINDER AG-1-VS PENETRANT
NIIN:00-826-0981
Kit Part:Y
MSDS Number: BHHPM
=== Responsible Party ===
Company:AMERICAN GAS AND CHEMICAL COMPANY.,LTD.
Address:220 PEGASUS AVENUE
City:NORTHVALE
State:NJ
ZIP:07647-1904
Country:US
Info Phone Num:201-767-7300
Emergency Phone Num:201-767-7300
Preparer's Name:GEORGE KOSEL,CHIEF CHEM
CAGE:03530
=== Contractor Identification ===
Company:AMERICAN GAS AND CHEMICAL COMPANY,LTD
Address:220 PEGASUS AVENUE,
City:N0RTHVALE
State:NJ
ZIP:07647-1904
Country:US
Phone:201-767-7300
CAGE:03530

=============  Composition/Information on Ingredients  =============

Name:TRIPHENYL PHOSPHATE
CAS:115-86-6
RTECS #:TC8400000
Fraction by Wt: 1.0%
OSHA PEL:3 MG/M3
ACGIH TLV:3 MG/M3; 9192

Name:DICHLORODIFLUOROMETHANE  (SARA III)
CAS:75-71-8
RTECS #:PA8200000
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:CAUSES IRRITATION OF
    EYES,SKIN,RESPIRATORY TRACT;INGESTION MAY CAUSE
    NAUSEA,VOMITING,ETC...INGESTION OF SMALL QUANTITIES IS USUALLY
    NON-FATAL UNLESS ASPIRATION OCCURS.ASPIRATION MAY LEAD TO CHEM ICAL
    PNEUMONITIS.
Effects of Overexposure:INHALATION:DUE TO ITS LOW VOLATILITY,EXPOSURE
    TO THIS MATERIAL UNDER AMBIENT CONDITIONS IS NOT EXPECTED TO
    PRODUCE ADVERSE HEALTH EFFECTS FOLLOWING NORMAL WORKPLACE
    EXPOSURE;SKIN:CAN CAUSE SLIGHT IRRI TATION;EYES:MAY CAUSE
    IRRITATION;INGESTION:CAN CAUSE GASTROINTESTINAL
    IRRITATION,NAUSEA,VOMITING AND DIARRHEA.
Medical Cond Aggravated by Exposure:NONE CURRENTLY KNOWN.

=======================  First Aid Measures  =======================

First Aid:INHALATION:REMOVE TO FRESH AIR:SEEK MEDICAL HELP.IF NOT
    BREATHING,GIVE ARTIFICIAL RESPIRATION,PREFERABLY MOUTH TO
    MOUTH.GIVE OXYGEN IF AVAILABLE; SKIN AND EYES:FLUSH WITH PLENTY OF
    WATER FOR ABOUT 15	MINUTES.SEEK MEDICAL HELP IF IRRITATIONPERSIST;
    INGESTION:DO NOT INDUCE VOMITING.IMMEDIATELY CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:REGULAR FOAM,WATER FOG,CARBON DIOXIDE,DRY CHEMICAL.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND
    SELF-CONTAINED BREATHING APPARATUS.COOL EXPOSED CONTAINERS WITH
    WATER SPRAY.AVOID BREATHING VAPOR OR FUMES.
Unusual Fire/Explosion Hazard:CONTAINERS MAY BURST/EXPLODE IN HEAT OF
    FIRE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE PROPER PERSONAL PROTECTION:REMOVE IGNITION
    SOURCES:RECOVER FREE LIQUID;USE SUITABLE INERT ABSORBENT SUCH AS
    SAND,CLAY,ETC.TO ABSORB LIQUID.KEEP MATERIAL OUT OF SEWERS/WATER
    WAYS.LG SPILLS MAY BE P ICKED UP BY VACUUM PUMPS,SHOVELS & PLACEIN
    DRUMS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL DRY PLACE BELOW
    120F.DO NOT PUNCTURE OR INCINERATE AEROSOL CANS.DO NOT STORE OR
    HANDLE NEAR HEAT,SPARKS OR OXIDANTS.KEEP PLAINLY LABLD
Other Precautions:DO NOT
    PRESSURIZE,CUT,WELD,BRAZE,SOLDER,DRILL,GRIND,OR EXPOSE SUCH
    CONTAINERS TO HEAT, FLAME,SPARKS OR OTHER SOURCES OF IGNITION:THEY
    MAY EXPLODE AND CAUSE INJURY OR DEATH.DO NOT ATTEMT TO CLEAN SINCE 
    RESIDUE IS DIFFICULT TO REMOVE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH APPROVED SELF-CONTAINED BREATHING
    APPARATUS IF NEEDED.
Ventilation:GENRAL VENTILATION IS SUFFICIENT.
Protective Gloves:NON ABSORBENT GLOVES
Eye Protection:SAFETY GLASSES
Other Protective Equipment:USE CHEMICAL RESISTANT APRON OR OTHER
    IMPERVIOUS CLOTHING,IF NEEDED,TO AVOID CONTAMINATING REGULAR
    CLOTHING.EYE-WASH FAC
Supplemental Safety and Health
NSN MANAGED BY GSA IS A 3 PART KIT OF TYPE II,METHOD C;PER GSA ID,KIT
    CONSISTS OF 9-7 OZ AEROSOL CANS (3 CANS EACH OF
    PENETRANT,DEVELOPER,AND CLEANER);PER MIL-I-25135,REV E AND
    QPL-25135-14/15,THIS PE NETRANT,AG-1-VS,IS QUALIFIED WITH D-4
    DEVELOPER & CLASS(1) REMOVER;SEE PNI-B & C FOR DEVELOPER & REMOVER
    DATA;KEY1:J7

==================  Physical/Chemical Properties  ==================

HCC:V2
Vapor Pres:<.1MMHG@20
Vapor Density:>1.0(AIR=1
Spec Gravity:0.98 (BULK)
Evaporation Rate & Reference:0.1 (N BUAC=1) (BULK)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK RED LIQUID;MILD ODOR
Percent Volatiles by Volume:>95%

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENT.
Stability Condition to Avoid:EXTREME HEAT
Hazardous Decomposition Products:BURNING CAN PRODUCE CARBON DIOXIDE
    AND/OR CARBON MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE PRODUCT SHOULD BE INCINERATED OR DISPOSED
    OF IN AN APPROVED DISPOSAL SITE OR FACILITY.CAN BE RECLAIMED AND
    RECYCLED.ASSURE CONFORMITY WITH ALL APPLICABLE LOCAL,STATE AND
    FEDERAL DISPOSAL REGULAT IONS.DO NOT INCINERATE AEROSOL CANS EMPTY
    OR FILLD

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
12001-29-5
FLAW-FINDER AG-RH CLEANER 71-55-6
38 0002966 ADV 256;DISINFECTANT CLEANER 107-21-1
67-63-0
1310-73-2
120-32-1
90-43-7
80-46-6
36445-71-3
12001-29-5
12001-29-5
CLEANING COMPOUND,SOLVENT MIXTURES 8030-30-6
141-78-6
78-93-3
67-63-0
12001-29-5
1,1,1,TRICHLOROETHANE 71-55-6
FLAW-FINDER AG-3D-FS PENETRANT 115-86-6
75-45-6
117-81-7
FLAW-FINDER AG-DH DEVELOPER 71-55-6
75-45-6
FLAW-FINDER AG-RH CLEANER (PRE 3/90) 71-55-6
124-38-9
REFRIGERANT 114 DICHLOROTETRAFLUOROETHANE 76-14-2
FLAW-FINDER AG-1-VS PENETRANT 115-86-6
75-71-8
FLAW-FINDER AG-DH DEVELOPER 71-55-6
75-71-8
FLAW-FINDER AG-RH CLEANER (PRE 3/90) 71-55-6
124-38-9
BATTERY FLUID (ELECTROLYTE) 7664-93-9
7732-18-5
NATIONAL REFRIGERANT 22 75-45-6
TETRACHLOROETHYLENE;CAT #EK114598 127-18-4
BATTERY, LEAD-ACID 7664-93-9
7439-92-1
1317-36-8
03-GY-68,BASE,GRAY 36231,POLYURETHANE 78-93-3
111-15-9
141-78-6
108-65-6
77-58-7
12001-29-5
CHEM BLEND PHOTO FIXER SG6042A 64-19-7
7783-18-8
7631-90-5
ILFOTEC HC FILM DEVELOPER 63149-47-3
111-42-2
111-46-6
123-31-9
67-43-6
12001-29-5
12001-29-5
12001-29-5
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
STANDARD CHLORIDE SOLUTION
12001-29-5
THIOGUANINE 154-42-7
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
THIOGUANINE 154-42-7
INTEX 8019 7664-38-2
16984-48-8
XAW-6487 PART A,EPOXY PRIMER 71-36-3
1330-20-7
107-98-2
123-86-4
NP-210-250/270/300/350/400/500 TONER 1317-61-9
12001-29-5
Y24 W 516;EXTERIOR WIOOD PRIMER,WHITE 64742-47-8
64742-88-7
14807-96-6
13463-67-7
A-100 ALKYD WOOD PRIMER;Y24 W 20 64742-47-8
64742-88-7
107-21-1
14464-46-1
14807-96-6
12003-38-2
13463-67-7
12001-29-5
12001-29-5
12001-29-5
145-037, HB-5/10/20 COULTER CALIBRATOR 151-50-8
12001-29-5
12001-29-5
12001-29-5
OATEY CLEANER 67-64-1
78-93-3
URALITE 3148 DARK AMBER (URALITE 3149-BLACK 5124-30-1
68310-52-1
URALITE 3148 DARK AMBER (URALITE 3149-BLACK 101-77-9
25214-70-4
69178-40-1
84-74-2
NITROGLYCERIN INJECTION, USP 55-63-0
57-55-6

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net