msds toxicity property"> toluene (sara iii)
"not hazardous" (not listed by mfr)
msds toxicity property">
Search   
MSDS  
:
 PR-1741; TYPE C-1/2, C-2, C-6; PART B
CAS  
:
 9003-35-4
108-88-3
NAME  
:
 phenol formaldehyde resin
toluene (sara iii)
"not hazardous" (not listed by mfr)
=====================  Product Identification  =====================

MSDS NAME:PR-1741; TYPE C-1/2, C-2, C-6; PART B
NIIN:01-128-4861
MSDS Number: BHHQF
=== Responsible Party ===
Company:PRODUCTS RESEARCH & CHEMICAL CORPORATION
Address:5430 SAN FERNANDO ROAD
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Country:US
Info Phone Num:818-240-2060
Emergency Phone Num:818-240-2060
Preparer's Name:AO
CAGE:DO563
=== Contractor Identification ===
Company:PRC-DESOTO INTERNATIONAL, INC. A PPG INDUSTRIES COMPANY
Address:5430 SAN FERNANDO RD
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Country:US
Phone:818-240-2060
CAGE:83574
Company:PRODUCTS RESEARCH & CHEMICAL
Address:NOW DBA COURTAULDS AEROSPACE
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Phone:818-240-2060
CAGE:DO563

=============  Composition/Information on Ingredients  =============

Name:PHENOL FORMALDEHYDE RESIN
CAS:9003-35-4
Fraction by Wt: <5%

Name:TOLUENE  (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: <5%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:"NOT HAZARDOUS"  (NOT LISTED BY MFR)
Fraction by Wt: >90%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS IRRITATING TO BODY TISSUES
    AND MAY SENSITIZE ALLERGIC REACTIONS OR CAUSE LIVER AND/OR KIDNEY
    DAMAGE WITH PROLONGED AND/OR REPEATED OVEREXPOSURE.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
    LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYE:IRRITATION, BURNING. SKIN:LOCAL IRRITATION,
    ALLERGIC DERMATITIS IN SENSITIZED PEOPLE.  INHALED:RESPIRATORY
    IRRITATION,ANESTHESIA,NAUSEA,DIZZINESS,HEADACHE.
    INGESTED:NAUSEA,VOMITING G/I DISTRESS, P OSSIBLE LIVER AND/OR
    KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:PEOPLE WITH A HISTORY OF AILMENTS
    OR WITH A PRE-EXISTING DISEASE INVOLVING THE SKIN, RESPIRATORY
    TRACT, LIVER OR KIDNEYS MAY BE AT INCREASED RISK FROM EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:REMOVE CONTAMINATED
    CLOTHING. WASH WITH SOAP & WATER. LAUNDER CLOTHING BEFORE REUSE.
    INHALED:REMOVE TO FRESH AIR. RESTORE BREATHING. GET MEDICAL CARE.
    INGESTED:DO NOT  INDUCE VOMITING. GET IMMEDIATE MEDICALATTENTION. -
    IF ANY IRRITATION IS SEVERE OR PERSISTS, GET MEDICAL CARE.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:68F 20C
Lower Limits:1.0
Upper Limits:7.0
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
    FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
    FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
    SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE IGNITION SOURCES.  WIPE/SOAK UP WITH
    CLOTH OR PAPER TOWEL OR INERT ABSORBANT. PUT IN DISPOSAL CONTAINER.
    REMOVE RESIDUE WITH 1,1,1-TRICHLOROETHANE.
Neutralizing Agent:NONE

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
    AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
    CONTAINERS FROM PHYSICAL DAMAGE.
Other Precautions:NONE

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT EXPECTED TO BE NECESSARY. USE NIOSH/MSHA
    APPROVED ORGANIC VAPOR CARTRIDGE AND DUST/MIST PRE-FILTER
    RESPIRATORS AS PER CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS
    AND NIOSH-RESPIRATOR SELECTION  WHEN EXPOSED ABOVE PEL/TLV.
Ventilation:GENERAL ROOM VENTILATION IS NORMALLY ADEQUATE. LOCAL
    EXHAUST MAY BE REQUIRED IF WORK AREA IS NOT VENTED.
Protective Gloves:SOLVENT IMPERVIOUS - RUBBER OR PLASTIC
Eye Protection:SAFETY GLASSES OR GOGGLES
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
    INDUSTRIAL-TYPE WORK CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD INDUSTRIAL HYGIENE PRACTICES AND
    RECOMMENDED PROCEDURES. AVOID UNNECESSARY CONTACT.
Supplemental Safety and Health
PART B OF A TWO PART KIT

==================  Physical/Chemical Properties  ==================

HCC:F2
Vapor Density:3.2
Spec Gravity:1.56
Evaporation Rate & Reference:2.0 (TOLUENE)
Solubility in Water:NEGLIGIBLE
Percent Volatiles by Volume:6

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH TEMPERATURES,
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,SULFUR
    OXIDES, POSSIBLE SOME HYDROGEN SULFIDE

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL
    APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. EPA WASTE
    NO D001.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
12001-29-5
FLAW-FINDER AG-RH CLEANER 71-55-6
38 0002966 ADV 256;DISINFECTANT CLEANER 107-21-1
67-63-0
1310-73-2
120-32-1
90-43-7
80-46-6
36445-71-3
12001-29-5
12001-29-5
CLEANING COMPOUND,SOLVENT MIXTURES 8030-30-6
141-78-6
78-93-3
67-63-0
12001-29-5
1,1,1,TRICHLOROETHANE 71-55-6
FLAW-FINDER AG-3D-FS PENETRANT 115-86-6
75-45-6
117-81-7
FLAW-FINDER AG-DH DEVELOPER 71-55-6
75-45-6
FLAW-FINDER AG-RH CLEANER (PRE 3/90) 71-55-6
124-38-9
REFRIGERANT 114 DICHLOROTETRAFLUOROETHANE 76-14-2
FLAW-FINDER AG-1-VS PENETRANT 115-86-6
75-71-8
FLAW-FINDER AG-DH DEVELOPER 71-55-6
75-71-8
FLAW-FINDER AG-RH CLEANER (PRE 3/90) 71-55-6
124-38-9
BATTERY FLUID (ELECTROLYTE) 7664-93-9
7732-18-5
NATIONAL REFRIGERANT 22 75-45-6
TETRACHLOROETHYLENE;CAT #EK114598 127-18-4
BATTERY, LEAD-ACID 7664-93-9
7439-92-1
1317-36-8
03-GY-68,BASE,GRAY 36231,POLYURETHANE 78-93-3
111-15-9
141-78-6
108-65-6
77-58-7
12001-29-5
CHEM BLEND PHOTO FIXER SG6042A 64-19-7
7783-18-8
7631-90-5
ILFOTEC HC FILM DEVELOPER 63149-47-3
111-42-2
111-46-6
123-31-9
67-43-6
12001-29-5
12001-29-5
12001-29-5
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
STANDARD CHLORIDE SOLUTION
12001-29-5
THIOGUANINE 154-42-7
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
PR-1741; TYPE C-1/2, C-2, C-6; PART B 9003-35-4
108-88-3
THIOGUANINE 154-42-7
INTEX 8019 7664-38-2
16984-48-8
XAW-6487 PART A,EPOXY PRIMER 71-36-3
1330-20-7
107-98-2
123-86-4
NP-210-250/270/300/350/400/500 TONER 1317-61-9
12001-29-5
Y24 W 516;EXTERIOR WIOOD PRIMER,WHITE 64742-47-8
64742-88-7
14807-96-6
13463-67-7
A-100 ALKYD WOOD PRIMER;Y24 W 20 64742-47-8
64742-88-7
107-21-1
14464-46-1
14807-96-6
12003-38-2
13463-67-7
12001-29-5
12001-29-5
12001-29-5
145-037, HB-5/10/20 COULTER CALIBRATOR 151-50-8
12001-29-5
12001-29-5
12001-29-5
OATEY CLEANER 67-64-1
78-93-3
URALITE 3148 DARK AMBER (URALITE 3149-BLACK 5124-30-1
68310-52-1
URALITE 3148 DARK AMBER (URALITE 3149-BLACK 101-77-9
25214-70-4
69178-40-1
84-74-2
NITROGLYCERIN INJECTION, USP 55-63-0
57-55-6

Free MSDS Search ( Providing 250,000+ Material Properties )