===================== Product Identification =====================
MSDS NAME:ILFOTEC HC FILM DEVELOPER
NIIN:01-066-7332
MSDS Number: BHHPZ
=== Responsible Party ===
Company:ILFORD PHOTO CORP.
Address:W.70 CENTURY ROAD
Box:288
City:PARAMUS
State:NJ
ZIP:07653
Country:US
Info Phone Num:201-265-6000
Emergency Phone Num:800-888-8372
CAGE:64145
=== Contractor Identification ===
Company:ILFORD PHOTO CORP
Address:W 70 CENTURY RD
Box:City:PARAMUS
State:NJ
ZIP:07653
Country:US
Phone:201-265-6000
CAGE:64145
============= Composition/Information on Ingredients =============
Name:DIETHANOLAMINE-SULFUR DIOXIDE COMPLEX
CAS:63149-47-3
Fraction by Wt: <30%
Name:DIETHANOLAMINE (SARA III)
CAS:111-42-2
RTECS #:KL2975000
Fraction by Wt: <45%
OSHA PEL:3 PPM
ACGIH TLV:3 PPM; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:DIETHYLENE GLYCOL
CAS:111-46-6
RTECS #:ID5950000
Fraction by Wt: <13%
Name:HYDROQUINONE (SARA III)
CAS:123-31-9
RTECS #:MX3500000
Fraction by Wt: <10%
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:DIETHYLENETRIAMINEPENTAACITIC ACID
CAS:67-43-6
RTECS #:MB8205000
Fraction by Wt: <3%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRODUCT MAY CAUSE EYE, SKIN &
RESPIRATORY TRACT IRRITATION. IT IS CONSIDERED A LOW HAZARD FOR
NORMAL INDUSTRIAL HANDLING.
Explanation of Carcinogenicity:IARC REPORTS HYDROQUINONE 'INSUFFICIENT
EVIDENCE TO CLASSIFY
Effects of Overexposure:EYE:CAUSES IRRITATION SKIN:CAUSES IRRITATION,
AND MAY SENSITIZE AN ALLERGIC REACTION. INHALED:UNLIKELY
EXPOSURE,MAY CAUSE IRRITATION. INGESTED:MAY BE HARMFUL IF
SWALLOWED. HMIS:MAY CAUSE G/I IRRITA
TION,NAUSEA,VOMITING,PALLOR,TINNITIS,DIZZINESS, OR INCREASED
RESPIRATORY RATE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:REMOVE CONTAMINATED
CLOTHING AND LAUNDER BEFORE REUSE. WASH SKIN WITH SOAP AND WATER.
INHALED: REMOVE TO FRESH AIR. INGESTED:IF CONSCIOUS,GIVE 1-2
GLASSES OF WATE R AND IMMEDIATELY INDUCE VOMITING. (NOTHING BY
MOUTH IF UNCONSCIOUS.) GET IMMEDIATE MEDICAL CARE. IF ANY
IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL CARE.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:>212F,>100C
Extinguishing Media:WATER SPRAY,DRY CHEMICAL,FOAM,CARBON DIOXIDE
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING TO PREVENT SKIN/EYE CONTACT.
Unusual Fire/Explosion Hazard:EXCESSIVE HEAT OR FIRE MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
================== Accidental Release Measures ==================
Spill Release Procedures:RECOVER AS LIQUID OR MOP UP WITH
CLOTH,PAPER,ETC.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL VENTILATED
AREA. KEEP TIGHTLY CLOSED WHEN NOT IN USE. KEEP AWAY FROM STRONG
ACIDS AND OXIDIZERS.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR IF PEL/TLV IS EXCEEDED.
Ventilation:NORMAL ROOM VENTILATION IS SUFFICIENT.
Protective Gloves:RUBBER,VINYL,OTHER IMPERVIOUS
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES
Other Protective Equipment:USE FACE SHIELD WHEN POURING LIQUIDS OR IF
SPLASHING IS LIKELY.
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT.
Supplemental Safety and Health
ILFORD STOCK NUMBERS MC9110079 AND MC9110085. COD = 1300 GM OXYGEN/KG.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:<32F,<0C
Vapor Pres:<10 MM
Vapor Density:4
Spec Gravity:1.24
pH:9.4
Evaporation Rate & Reference:SLOW (NO REFERENCE)
Solubility in Water:COMPLETE
Appearance and Odor:SLIGHTLY YELLOW COLORED, VISCOUS LIQUID, NO ODOR
Percent Volatiles by Volume:33%WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZERS AND MINERAL ACIDS
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
SULFUR DIOXIDE, NITROGEN OXIDES
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
MFR SUGGESTS FLUSH TO ACID-FREE SEWER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|