Duniway Part #: SANTOVAC-5
®
Santovac Fluids
Material Safety Data Sheet
Page 1 of 5
1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
SANTOVAC ® 5 POLYPHENYL ETHER LUBRICANT
PRODUCT NAME:
Date: 01/03/02
Chemical Family: polyphenyl ether
SANTOVAC® FLUIDS, INC., 8 Governor Drive, St. Charles, MO 63301
FOR CHEMICAL EMERGENCY, SPILL LEAK, FIRE, EXPOSURE, OR ACCIDENT
Call CHEMTREC - Day or Night - 1-800-424-9300. Toll free in the continental U.S., Hawaii, Puerto Rico,
Canada, Alaska, or Virgin Islands. For calls originating elsewhere: 703-527-3887 (collect calls accepted)
For additional non-emergency information, call: 636-723-0240
2. COMPOSITION/INFORMATION ON INGREDIENTS
Santovac® 5 polyphenyl ether is a five-ring polyphenyl ether. The CAS Number for this material is 2455-71-2.
It is not a hazardous chemical(s) under the criteria of the OSHA Hazard Communication Standard (29 CFR
1910.1200).
3. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
Appearance and Odor: light yellow essentially clear liquid with no odor to slight phenolic odor
NO SIGNIFICANT HAZARDS ASSOCIATED WITH THIS MATERIAL
POTENT IAL HEALTH EFFECTS
Likely Routes of Exposure: skin contact
Occupational exposure to this material has not been reported to cause significant adverse health effects. On
the basis of available information, exposure to Santovac® 5 polyphenyl ether lubricant Is not expected to
produce significant adverse human health effects when recommended safety precautions are followed.
Refer to Section 11 for toxicological Information.
4. FIRST AID MEASURES
IF IN EYES OR ON SKIN, Immediate first aid is not likely to be required. However, this material can be
removed with water. Wash heavily contaminated clothing before reuse.
IF INHALED, Immediate first aid is not likely to be required. However, if symptoms occur, remove to fresh air.
Remove material from eyes, skin and clothing.
SANTOVAC ® MATERIAL SAFETY DATA SHEET
SANTOVAC® 5 POLYPHENYL ETHER LUBRICANT Page 2 of 5
IF SWALLOWED, Immediate first aid is not likely to be required. A physician or Poison Control Center can be
contacted for advice.
5. FIRE FIGHTING MEASURES
550°F (287°C)
Flash Point: Method: Cleveland Open Cup
1135°F (612°C)
Autoignition Temperature:
660°F (348°C)
Fire Point:
Extinguishing Media: In case of fire, use water spray (fog), foam, dry chemical, or CO2.
Unusual Fire and Explosion Hazards: None known
Fire Fighting Equipment: Fire fighters and others exposed to products of combustion should wear self-
contained breathing apparatus. Equipment should be thoroughly decontaminated after use.
6. ACCIDENTAL RELEASE MEASURES
Contain large spills with dikes and transfer the material to appropriate containers for reclamation or disposal.
Absorb remaining material or small spills with an inert material and then place in a chemical waste container.
Flush residual spill area with water.
Refer to Section 13 for disposal information and Section 15 for reportable quantity information.
7. HANDLING AND STORAGE
HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICES. THESE
PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE AND REMOVAL OF MATERIAL FROM EYES,
SKIN AND CLOTHING.
Emptied container retains vapor and product residue. Observe all labeled safeguards until container is
cleaned, reconditioned, or destroyed.
Storage: Product is stable under normal conditions of storage and handling.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Eye Protection: This product does not cause significant eye irritation or eye toxicity requiring special
protection. Use good industrial practice to avoid eye contact.
Skin Protection: Although it does not present a significant skin concern, minimize skin contamination by
following good industrial practice. Wearing protective gloves is recommended. Wash hands and
contaminated skin thoroughly after handling.
Respiratory Protection: Avoid breathing mist. Use NIOSH/MSHA approved respiratory protection equipment
when airborne exposure is excessive. Consult respirator manufacturer to determine appropriate type
equipment for given application. Observe respirator use limitations specified by NIOSH/MSHA or the
manufacturer. Respiratory protection programs must comply with 29 CFR 1910.134.
Ventilation: Provide natural or mechanical ventilation to minimize exposure. If practical, use local mechanical
SANTOVAC ® MATERIAL SAFETY DATA SHEET
SANTOVAC® 5 POLYPHENYL ETHER LUBRICANT Page 3 of 5
exhaust ventilation at sources of air contamination such as open process equipment.
Airborne Exposure Limits:
Santovac® 5 Polyphenyl Ether Lubricant
Product:
OSHA PEL: None established
ACGIH TLV: None established
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: light yellow essentially clear liquid
Odor: Odorless to slight phenolic
889°F @ 760 mm Hg
Boiling Point:
40°F
Pour Point:
1.195 - 1.201 @ 25/25°C
Specific Gravity:
pH: neutral
Vapor Density: 15.5 (air = 1)
Solubility: soluble in acetone and light aromatic solvents; insoluble in water
NOTE: These physical data are typical values based on material tested but may vary from sample to sample.
Typical values should not be construed as a guaranteed analysis of any specific lot or as specifications for
the product.
10. STABILITY AND REACTIVITY
Stability: Product is stable under normal storage and handling conditions.
Materials to Avoid: Exposure to materials that are highly oxidizing should be avoided.
Hazardous Decomposition Products: Continued use at temperatures above 425°C may result in the formation
of benzene and phenol. If the product is burned, complete combustion produces carbon dioxide and water
and partial combustion produces carbon monoxide, smoke, soot and low molecular weight hydrocarbons.
Hazardous Polymerization: Does not occur.
11. TOXICOLOGICAL INFORMATION
Data from laboratory studies with Santovac® 5 polyphenyl ether lubricant are summarized below.
Santovac® 5 Polyphenyl Ether Lubricant
Single exposure (acute) studies indicate:
SANTOVAC ® MATERIAL SAFETY DATA SHEET
SANTOVAC® 5 POLYPHENYL ETHER LUBRICANT Page 4 of 5
Oral - Practically Nontoxic (Rat LD50 > 34,600 mg/kg)
Oral - Practically Nontoxic (Rabbit LD50 > 34,600 mg/kg)
Dermal - Practically Nontoxic (Rabbit LD50 > 34,600 mg/kg)
Inhalation - Practically Nontoxic (Rat 4-hr LC50 > 47 mg/l. No deaths and no signs of toxicity were
observed in animals exposed to 47 mg/l, the highest atmospheric
concentration achievable by heating the material to 329°C in this
study.)
Eye Irritation - Nonirritating (Rabbit, 0.0/110.0)
Skin Irritation - Nonirritating (Rabbit, 24-hr exposure, 0.0/8.0)
Laboratory studies have been conducted on similar polyphenyl ether formulations and these data are
considered representative of Santovac® 5 Lubricant.
In a controlled skin contact study, no skin irritation (primary or cumulative) or skin allergy was observed in
humans following repeated exposures to a polyphenyl ether formulation similar to Santovac® 5 Lubricant.
Increases in liver weights and liver/body weight ratios with accompanying increase in liver cell size,
considered to be related in increased liver metabolic activity and increases in adrenal weight were noted in
rats following repeated skin exposure (4-weeks) to a second polyphenyl ether formulation. This same
formulation produced no genetic changes in standard tests using animal or bacterial cells.
12. ECOLOGICAL INFORMATION
Santovac® Fluids, Inc. has not conducted environmental studies with this product.
13. DISPOSAL CONSIDERATIONS
This material when discarded is not a hazardous waste as defined by the Resource, Conservation and
Recovery Act (RCRA), 40 CFR 261. Dispose of in accordance with all federal, state and local environmental
regulations. Recommended method of disposal is by high temperature incineration at a RCRA approved
TSDF. If there are any questions regarding the disposal of this material, please consult the Environmental,
Health & Safety Department of Santovac Fluids, Inc. at 636-946-2355.
14. TRANSPORT INFORMATION
The data provided in this section is for information only. Please apply the appropriate regulations to properly
classify your shipment for transportation.
This product is not hazardous under the applicable DOT, ICAO/IATA, or IMDG regulations.
15. REGULATORY INFORMATION
TSCA Inventory: All components are listed.
SARA Hazard Notification
Hazard Categories Under Title III Rules (40 CFR 370): Not Applicable
SANTOVAC ® MATERIAL SAFETY DATA SHEET
SANTOVAC® 5 POLYPHENYL ETHER LUBRICANT Page 5 of 5
Section 313 Toxic Chemical(s): Not Applicable
CERCLA Reportable Quantity: Not Applicable
Refer to Section 2 for OSHA Hazardous Chemical(s) and Section 13 for RCRA classification.
16. OTHER INFORMATION
Reason for revision: Section 13 - update disposal language
Revision Number: 3
Santovac® 5 is a trademark of Santovac® Fluids, Inc.
NOTICE: Although the information and recommendations set forth herein (hereinafter “Information�) are presented in good
faith and believed to be correct as of the date hereof, Santovac® Fluids, Inc. makes no representations as to the
completeness or accuracy thereof. Information is supplied upon the conditions that the persons receiving same will make
their own determinations as to its suitability for their purposes prior to use. In no event will Santovac® Fluids, Inc. be
responsible for damages of any nature whatsoever resulting from the use of or reliance upon information. NO
REPRESENTATIONS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, OR MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR
THE PRODUCT TO WHICH INFORMATION REFERS.
Date 01/03/02 Supercedes 01/03/00
|