INTERNATIONAL PAINT INC -- INTERTUF HYDRO CARBON EPOXY WHITE, KHA300
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXWYG
MSDS NAME: INTERTUF HYDRO CARBON EPOXY WHITE, KHA300
Responsible Party
Name: INTERNATIONAL PAINT CO INC
Address: 2270 MORRIS AVE
City: UNION NJ 07083-5704
Info Phone: 713-682-1711
Emergency Phone Number: 800-854-6813
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: INTERNATIONAL PAINT INC
Address: 6001 ANTOINE DR
City: HOUSTON TX 77091
Phone: 800-589-1267/800-854-6813
=======================================================
Ingredients
=======================================================
Cas: 64742-95-6
RTECS #: WF3400000
Name: SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (NAPHTHA, LIGHT AROMATIC
(SOLVENT NAPHTHA)). VP: 10.2
% Wt: 10-15
OSHA PEL: 100.00 PPM (MFR)
ACGIH TLV: 100.00 PPM (MFR)
------------------------------
Cas: 110-43-0
RTECS #: MJ5075000
Name: 2-HEPTANONE; (METHYL N-AMYL KETONE). VP: 2.8
% Wt: 5-10
OSHA PEL: 100 PPM
ACGIH TLV: 50 PPM; 9495
------------------------------
Cas: 25036-25-3
Name: BISPHENOL A EPOXY RESIN; (EPOXY RESIN)
% Wt: 1-5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 25068-38-6
RTECS #: SL6475000
Name: BISPHENOL A-EPICHLOROHYDRIN COPOLYMER; (EPOXY RESIN)
% Wt: 15-20
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: EYES:CAN CAUSE IRRITATION WITH REDNESS, TEARING,
AND BLURRED VISION. SKIN:IRRITATING. MAY RESULT IN DERMATITIS. MAY CAUSE
SENSITIZATION OR OTHER ALLERGIC RESPONSES. INHALATION: MAY CAUSE IRRITA TION.
INGESTION:MAY CAUSE GASTRO-INTESTINAL IRRITATION. CHRONIC: OVEREXPOSURE TO
AND MISUSE OF SOLVENTS(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: HLTH HAZ: HAS BEEN LINKED TO PERMANENT
BRAIN AND NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated By Exposure: SKIN AND RESPIRATORY CONDITIONS.
First Aid: EYE:FLUSH IMMEDIATELY WITH COPIOUS QUANTITIES OF WATER FOR AT LEAST
15 MINUTES. GET MEDICAL ATTENTION IMMEDIATELY. SKIN:REMOVE CONTAMINATED
CLOTHING, WASH SKIN WITH PLENTY OF SOAP AND WATER. LAUNDER C LOTHES BEFORE
REUSE. INHAL:REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF NEEDED. GET
MEDICAL ATTENTION. INGEST:CALL A PHYSICIAN IMMEDIATELY TO DETERMINE WHETHER
OR NOT TO INDUCE VOMITING.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION. AVOID INHALATION OF
VAPORS. VENTILATE AREA. CLEAN UP WITH ABSORBENT MATERIALS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS.
Handling And Storage Precautions: STORE IN BUILDING DESIGNED AND PROTECTED FOR
STORAGE OF LIQUIDS WITH NFPA CLASS GIVEN BY OSHA CLASS.
Other Precautions: AVOID BREATHING DUST OR CHIPS FROM SANDING OR BLASTING
SURFACES COATED WITH THIS PRODUCT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: 100F,38C
Extinguishing Media: FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). SMOTHER FLAMES W/ONE OF THE EXTING MEDIA. H*2O MAY BE USED TO COOL
UNOPENED CNTNRS, BUT MUST NOT BE(SUPDAT)
Unusual Fire/Explosion Hazard: NONE KNOWN UNLESS OTHERWISE NOTED. CONTAINS FLAM
SOLV. DO NOT USE IN AREAS WHERE SPARKS/OPEN FLAME ARE PRESENT. CLSD CNTNRS
MAY EXPLODE WHEN EXPOSED TO (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH/MSHA APPRVD RESP APPROP FOR EXPOS OF CONCERN (FP
N). IN OUTDOOR/OPEN AREAS, W/UNRESTRICTED VENT, USE NIOSH/MSHA APPRVD RESP
I/A/W 29 CFR 1910.134 TO REMOVE A COMBINATION OF PARTICULATES AND VAPO RS.
Ventilation: PROVIDE SUFFICIENT VENT, IN VOLUME AND PATTERN, TO KEEP TLV &
LEL OF HAZ INGRED BELOW LIMITS SPECIFIED (SUPDAT)
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPRVD EMER EYE WASH & DELUGE SHOWER (FP N).
WEAR APPROP IMPERVIOUS PROTECTIVE CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices: REMOVE AND WASH SOILED CLOTHING BEFORE REUSE, WASH
HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health: FIRE FIGHT PROC:BE USED AS EXTING MEDIA. TAKE
CARE TO PREVENT SPREAD OF BURNING LIQUID W/H*2O. CLOSED CNTNRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:EXTREME HEAT. VENT:& TO REMOVE
DECOMPOS ITION PRODUCTS DURING WELDING/FLAME CUTTING ON SURFACES COATED
W/THIS PROD.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >300F,>149C
Vapor Pres: SEE INGRED
Vapor Density: HVR/AIR
Spec Gravity: 1.52 (FP N)
Evaporation Rate & Reference: SLOWER THAN ETHER
Appearance and Odor: NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume: 20(WT)
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE KNOWN UNLESS OTHERWISE NOTED. OXIDIZING
AGENTS.
Materials To Avoid: NONE KNOWN UNLESS OTHERWISE NOTED. STORE AWAY FROM DIRECT
HEAT, FLAME OR SPARK.
Hazardous Decomposition Products: CO, CO*2, VARIOUS HYDROCARBON FRAGMENTS,
ALDEHYDES.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: INTERTUF HYDRO CARBON EPOXY WHITE, KHA300
Company: INTERNATIONAL PAINT INC
Street: 6001 ANTOINE DR
City: HOUSTON TX
Zipcode: 77091
Health Emergency Phone: 800-854-6813
Label Required IND: Y
Date Of Label Review: 07/05/1995
Status Code: C
Label Date: 07/05/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Moderate
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE: EYES:CAN CAUSE IRRITATION WITH
REDNESS, TEARING, AND BLURRED VISION. SKIN:IRRITATING. MAY RESULT IN
DERMATITIS. INHALATION: MAY CAUSE IRRITATION. INGESTION:MAY CAUSE
GASTRO-INTESTI NAL IRRITATION. CHRONIC: MAY CAUSE SENSITIZATION OR OTHER
ALLERGIC RESPONSES. OVEREXPOSURE TO AND MISUSE OF SOLVENTS HAS BEEN LINKED TO
PERMANET BRAIN AND NERVOUS SYSTEM DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.