Search   
MSDS  : NICKEL CADMIUM BATTERY
CAS  : 1310-65-2
1310-58-3
1310-73-2
NAME  :
ENERGIZER POWER SYSTEMS DIV OF -- NICKEL CADMIUM BATTERY
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 01-297-6282
MSDS Num: CJVNC
MSDS NAME: NICKEL CADMIUM BATTERY
Article: Y
Responsible Party
Name: ENERGIZER POWER SYSTEMS DIV OF EVEREADY BATTERY CO INC
Address: US HIGHWAY 441N
Box: UNKNOW
City: ALACHUA FL 32615
Info Phone: (216)-835-7368
Emergency Phone Number: (216)-835-7368
Resp. Party Other MSDS No.: ASSEMB: 7916940-00 BATTERY: 7916604-00
Chemtrec IND/Phone: (800)424-9300
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: ENERGIZER POWER SYSTEMS DIV OF EVEREADY BATTERY CO INC
Address: US HIGHWAY 441N
Box: UNKNOW
City: ALACHUA FL 32615
Phone: (216)-835-7368
=======================================================
Item Description Information
=======================================================
Item Manager: S9G
Item Name: BATTERY ASSEMBLY
Unit of Issue: EA
Quantitative Expression: NOT AVAILABLE
UI Container Qty: 10
=======================================================
Regulated Components
=======================================================
Regulated Component Name: COBALT (AS COBALT METAL (CAS 7440-48-4), COBALT OXIDE
(CAS 1307-96-6), COBALT HYDROXIDE (CAS 21041-93-0))
Percent Text: 0.5-2%
Regulated Component Name: LITHIUM HYDROXIDE
CAS: 1310-65-2
Percent Text: 0-4%
Regulated Component Name: NICKEL (AS NICKEL METAL (CAS 7440-02-0), NICKEL OXIDE
(CAS 1313-99-1), NICKEL HYDROXIDE (CAS 12054-48-7))
Percent Text: 20-32%
Regulated Component Name: POTASSIUM HYDROXIDE
CAS: 1310-58-3
Percent Text: 0-4%
Regulated Component Name: SODIUM HYDROXIDE
CAS: 1310-73-2
Percent Text: 0-4%
Regulated Component Name: CADMIUM (AS CADMIUM METAL (CAS 7440-43-9), CADMIUM
OXIDE (CAS 1306-19-0), CADMIUM HYDROXIDE (CAS 21041-95-2))
Percent Text: 13-22%
=======================================================
Health Hazards Data
=======================================================
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: YES
Effects of Exposure: INGESTION: CONTENTS OF OPEN BATTERY CAN CAUSE SERIOUS
CHEMICAL BURNS OF MOUTH, ESOPHAGUS, & GASTROINTESTINAL TRACT.
INHALATION: RESPIRATORY IRRITATION. CADMIUM OXIDE FUMES CAN CAUSE METAL FUME
FEVER. HYPERSENSITIVITY TO NICKEL CAN CAUSE ALLERGIC PULMONARY ASTHMA. SKIN:
CAN CAUSE SKIN IRRITATION &/OR CHEMICAL BURNS. CAN CAUSE SKIN
SENSITIZATION & AN ALLERGIC CONTACT DERMATITIS. EYE: CAN CAUSE SEVE RE
IRRITATION & CHEMICAL BURNS.
Explanation Of Carcinogenicity: NICKEL, CADMIUM, NICKEL COMPOUNDS, CADMIUM
COMPOUNDS, AND COBALT COMPOUNDS ARE LISTED AS POSSIBLE CARCINOGENS BY
INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC) OR NATIONAL TOXICOLOGY
PROGRAM (NTP) .
Signs And Symptions Of Overexposure: INGESTION: CONTENTS INCLUDE TOXIC CADMIUM
& CADMIUM COMPOUNDS CAN CAUSE SALIVATION, CHOKING, NAUSEA, PERSISTENT
VOMITING, DIARRHEA, ABDOMINAL PAIN, DIZZINES, FAINTNESS, UNCONSCIOUSNESS,
& POSSIBLE LIV ER & KIDNEY INJURY.
First Aid: INGESTION: DO NOT INDUCE VOMITING OR GIVE FOOD OR DRINK. SEEK
MEDICAL ATTENTION IMMEDIATELY. CALL NATIONAL BATTERY INGESTION HOTLINE FOR
ADVICE & FOLLOW-UP (202-625-3333) COLLECT, DAY OR NIGHT. INHAL ATION:
PROVIDE FRESH AIR & SEEK MEDICAL ATT'N. SKIN: REMOVE CONTAMINATED
CLOTHING & WASH SKIN WITH SOAP & WATER. IF A CHEMICAL BURN OCCURS OR
IF IRRITATION PERSISTS, SEEK MEDICAL ATT'N. EYES: IMMEDI ATELY FLUSH EYES
THOROUGHLY WITH WTER FOR AT LEAST 15 MIN, LIFTING UPPER & LOWER LIDS,
UNTIL NO EVIDENCE OF THE CHEMICAL REMAINS. SEEK MEDICAL ATT'N.
=======================================================
Handling and Disposal
=======================================================
Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL,
STATE AND LOCAL REGULATIONS. WHEN GENERATED AS A WASTE, THESE BATTERIES MAY
BE REGULATED BY THE RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) AS A D0 06
(CADMIUM) HAZARDOUS WASTE. RECYCLING OF THIS PRODUCT MAY BE AVAILABLE. CAN
CALL 1-800-8-BATTERY FOR INFORMATION.
Handling And Storage Precautions: BATTERY SHOULD NOT BE OPENED. SHOULD A CELL
BECOME DISASSEMBLED, THE ELECTRODE SHOULD BE STORED IN A FIREPROOF CABINET,
AWAY FROM COMBUSTIBLES. STORE IN A COOL, WELL VENTILATED AREA. ELEVATED
TEMPERA TURES CAN RESULT IN SHORTENED BATTERY LIFE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: FLOOD AREA W/ WATER. IF BATTERIES BURNING, WATER MAY NOT
EXTINGUISH, BUT WILL COOL ADJACENT BATTERIES & CONTROL SPREAD OF FIRE.
CO2, DRY CHEMICAL, & FOAM EXTINGUISHERS MAY BE USED.
Fire Fighting Procedures: FIRE FIGHTERS SHOULD WEAR SELF-CONTAINED BREATHING
APPARATUS. BURNING NICKEL-CADMINUM BATTERIES CAN PRODUCE TOXIC FUMES
INCLUDING NICKEL, NICKEL OXIDES, CADMIUM OXIDES, AND COBALT OXIDES.
Unusual Fire/Explosion Hazard: WHEN WATER IS USED HOWEVER, HYDROGEN GAS WILL BE
EVOLVED WHICH CAN FORM AN EXPLOSIVE MIXTURE IN A CONFINED SPACE. METL-X
(GRAPHITE BASE) WILL EXTINGUISH BURNING NICKEL CADMIUM BATTERIES AS WILL
SAND, DRY GROUND DOLOMITE OR SODA ASH. THESE MATERIALS ACT AS SMOTHERING
AGENTS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT NECESSARY UNDER NORMAL CONDITIONS.
Ventilation: NOT NECESSARY UNDER NORMAL CONDITIONS.
Protective Gloves: USE NEOPRENE OR NATURAL RUBBER GLOVES IF HANDLING OPEN OR
LEAKING BATTERY.
Eye Protection: WEAR SAFETY GLASSES WITH SIDE SHIELDS IF HANDLING OPEN OR
LEAKING BATTERY.
Supplemental Safety and Health: BATTERY SHOULD NOT BE OPENED OR BURNED.
EXPOSURE TO THE INGREDIENTS CONTAINED WITHIN OR THEIR COMBUSTION PRODUCTS
COULD BE HARMFUL. SHOULD A CELL BECOME DISASSEMBLED, THE ELECTRODE SHOULD BE
STORED IN A FIREPROOF CABINET, AWAY FROM COMBUSTIBLES.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: Z5
=======================================================
Reactivity Data
=======================================================
Materials To Avoid: FIRE & COMBUSTIBLES.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
Transport Information: THE TRANSPORTATION OF DRY CELL BATTERIES MANUFACTURED OR
SOLD BY EVERREADY BATTERY COMPANY IS NOT REGULATED BY THE U.S. DEPARTMENT OF
TRANSPORTATION OR THE MAJOR INTERNATIONAL REGULATORY BODIES.
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: AS AN ARTICLE, THIS BATTERY AND ITS CONTENTS ARE
NOT SUBJECT TO THE REQUIREMENTS OF THE EMERGENCY PLANNING AND COMMUNITY
RIGHT-TO-KNOW ACT.
=======================================================
Other Information
=======================================================
Other Information: THE FEDERAL UNIVERSAL WASTE RULE CITED AT 40 CFR PART 273
GOVERNS NICKEL CADMIUM BATTERY RECYCLING AND MAY BE APPLICABLE IN YOUR STATE.
=======================================================
Transportation Information
=======================================================
Trans ID NO: 150514
MSDS NAME: NICKEL CADMIUM BATTERY
MSDS Prepared Date: 08/03/1995
Review Date: 12/04/1999
Multiple KIT Number: 0
Unit Of Issue: EA
Container QTY: 10
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: NICKEL CADMIUM BATTERY
Company: ENERGIZER POWER SYSTEMS DIV OF EVEREADY BATTERY CO INC
Street: US HIGHWAY 441N
PO Box: UNKNOW
City: ALACHUA FL
Zipcode: 32615
Health Emergency Phone: (216)-835-7368
Label Required IND: Y
Date Of Label Review: 12/04/1999
Status Code: A
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: TARGET ORGANS: N/P. INGESTION: CONTENTS OF OPEN
BATTERY CAN CAUSE SERIOUS CHEMICAL BURNS OF MOUTH, ESOPHAGUS, &
GASTROINTESTINAL TRACT. INHALATION: RESPIRATORY IRRITATION. CADMIUM OXIDE
FUMES CAN CA USE METAL FUME FEVER. HYPERSENSITIVITY TO NICKEL CAN CAUSE
ALLERGIC PULMONARY ASTHMA. SKIN: CAN CAUSE SKIN IRRITATION &/OR CHEMICAL
BURNS. CAN CAUSE SKIN SENSITIZATION & AN ALLERGIC CONTACT DERMATITIS .
EYE: CAN CAUSE SEVERE IRRITATION & CHEMICAL BURNS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
X-CEL AR-300
INTERCARE 755 LIGHT BASE, ESA011 13463-67-7
21645-51-2
110-43-0
107-87-9
1330-20-7
7631-86-9
64742-95-6
71-36-3
25551-13-7
MOLECULAR WEIGHT STANDARDS LYOPHILIZED, PRESTAINED, 26041 2580-78-1
151-21-3
PSX-700 RESIN
OPD (O-PHENYLENEDIAMINE DIHYDROCHLORIDE), 15974 615-28-1
CLOVER SILICON CARBIDE GREASE MIX - ALL GRADES, 51803 64742-53-6
409-21-2
64755-01-7
64742-52-5
MOPS (3-(N-MORPHOLINO) PROPANESULFONIC ACID), 11345 1132-61-2
MEM SODIUM PYRUVATE SOLUTION 100MM (100X), LIQUID, 11360
HALOCARBON 4.2 OIL 9002-83-9
BSTFA, 0038820 25561-30-2
STADIS 450 CONDUCTIVITY IMPROVER
THERACIDE 67-63-0
68391-01-5
68956-79-6
N-29 NEOPRENE: COLD BOND
HP 51641A INK CARTRIDGE
PSX-700 CURE
PSX-700FD CURE
SMALL SCREW THREADLOCKER 222, 22221 25852-47-5
9004-96-0
81-07-2
80-15-9
67-56-1
112945-52-5
613-48-9
13463-67-7
ITC 100 HT CERAMIC COATING
DYN-O-MELT
NEUTRALIZATION SOLUTION C, N3029
P2692, PHOSPHATE BUFFERED SALINE, 10X CONCENTRATE, (SUPDAT)
CALIBRATOR C (RF IGM), C5211
CALIBRATOR B (RF IGM), C5086
AR-GLO 4/E
NICKEL CADMIUM BATTERY 1310-65-2
1310-58-3
1310-73-2
HP C3102A CYAN TONER
PERMATEX ALL PURPOSE SPRAY ADHESIVE, 82019, 118DA.
NORDSTROM 950 SEALANT (BULK GRADE)
HALOCARBON 95 OIL 9002-83-9
HALOCARBON 700 OIL 9002-83-9
AEROSOL #2105 LACQUER RFU COATING L2105AERO
GLB ALGIMYCIN 600
SULFURIC ACID, S978.10 7664-93-9
7732-18-5
BETA-MERCAPTOETHANOL (48.7%), Z523 60-24-2
DENATURING SOLUTION, Z565 593-84-0
60-24-2
PHENOL: CHLOROFORM: ISOAMYL ALCOHOL, Z566 108-95-2
67-66-3
PHOSPHORIC ACID, 75%, P376.32 7664-38-2
7732-18-5
HYDROCHLORIC ACID, 37%, H627.10 7732-18-5
7647-01-0
CARBENICILLIN, DISODIUM SALT, 10177 4800-94-6
NITROGEN 7727-37-9
DURSBAN PRO INSECTICIDE; PRODUCT CODE: 46482
SLIP PLATE AEROSOL
HALOCARBON 27 OIL 9002-83-9
MARATHON,1000 8052-41-3
64741-65-7
1330-20-7
100-41-4
MARATHON,1005 8052-41-3
64741-65-7
1330-20-7
100-41-4
MARATHON,1010 8052-41-3
64741-65-7
1330-20-7
100-41-4
BUFFER, REFERENCE STANDARD, PH 4.00, 1500
23X3, DEFTHANE SATIN #2 64742-88-7
TRACTOR HYDRAULIC FLUID, CPS226606
MARATHON,1020 8052-41-3
64741-65-7
1330-20-7
100-41-4

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net