INTERNATIONAL TECHNICAL CERAMI -- ITC 100 HT CERAMIC COATING
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJVKK
MSDS NAME: ITC 100 HT CERAMIC COATING
Responsible Party
Name: INTERNATIONAL TECHNICAL CERAMICS INC
Box: 1726
City: PONTE VEDRA FL 32004
Info Phone: 904-285-0200
Emergency Phone Number: 904-285-0200
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: INTERNATIONAL TECHNICAL CERAMICS, INC.
Box: 1726
City: PONTE VEDRA FL 32004
Phone: 904-285-0200
Contract Number: N00406-99-M-M326
=======================================================
Item Description Information
=======================================================
=======================================================
Ingredients
=======================================================
Name: NON-TOXIC CERAMIC COMPOUNDS
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: MATERIAL IS NON-TOXIC; HOWEVER, IF INHALED,
SWALLOWED OR PAINTED ON SKIN, CAN CREATE HEALTH HAZARDS. SIGNS AND SYMPTOMS
OF EXPOSURE: LUNG, SKIN, OR EYE IRRITATON CAN OCCUR IF UNPROTECTED DURING
APPLICATION.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: ANY PRE-EXISTING LUNG, SKIN, OR EYE
DISEASE WILL BE AGGRAVATED WITH INADEQUATE PROTECTION DURING APPLICATION.
First Aid: INGEST: CALL MD IMMEDIATELY (FP N). INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION (FP N). EYES:
IMMEDIATELY FLUSH WITH POTABLE WATER FOR AT LEAST 15 MINUTES, SEEK A
SSISTANCE FROM MD (FP N). SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD.
(FPN). WASH EYES AND BODY IMMEDIATELY UPON CONTACT.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: PUT IN PROPER RECEPTACLES AND DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE, AND FEDERAL LAWS.
Waste Disposal Methods: THIS MATERIAL IF DISPOSED WILL HARDEN BY OUTSIDE
TEMPERATURE INTO SOLID FORM THAT IS NON-HAZARDOUS TO NATURE. DISPOSAL MUST BE
IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS (FP N).
Handling And Storage Precautions: KEEP CONTAINER LIDS TIGHTLY SEALED WHEN NOT
IN USE.
Other Precautions: USE OSHA APPROVED AIR PURIFYING RESPIRATOR, SAFETY GOGGLES,
WORK CLOTHES AND GLOVES DURING APPLICATION.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point: >2204.3C, 4000.F
Extinguishing Media: N/A. MEDIA SUITABLE FOR SURROUNDING FIRE (FP N).
Fire Fighting Procedures: NONE. MATERIAL IS USED IN HIGH TEMPERATURE
APPLICATIONS AS FIRE INSULATOR. USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED AIR PURIFYING RESPIRATOR.
Ventilation: LOCAL EXHAUST AND MECHANICAL (GENERAL): BEST
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: EYE WASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA (FP N). STANDARD WORK UNIFORMS THAT PROTECT SKIN.
Work Hygienic Practices: ATTENTION TO CLEANLINESS AND PERSONAL CARE WILL
PREVENT PROBLEMS.
=======================================================
Physical/Chemical Properties
=======================================================
Boiling Point: >2204.3C, 4000.F
Melt/Freeze Pt: >2760.C, ######F
Appearance and Odor: ODORLESS CERAMIC PASTE.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ITC 100 HT CERAMIC COATING
Company: INTERNATIONAL TECHNICAL CERAMICS, INC.
PO Box: 1726
City: PONTE VEDRA FL
Zipcode: 32004
Health Emergency Phone: 904-285-0200
Label Required IND: Y
Date Of Label Review: 11/16/1999
Status Code: A
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: MATERIAL IS NON-TOXIC; HOWEVER, IF INHALED,
SWALLOWED OR PAINTED ON SKIN, CAN CREATE HEALTH HAZARDS. SIGNS AND SYMPTOMS
OF EXPOSURE: LUNG, SKIN, OR EYE IRRITATON CAN OCCUR IF UNPROTECTED DURING
APPLICATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.