LOCTITE CORPORATION -- PRISM ? 454 SURF-INSENSIT GEL INST ADH
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 01-388-5620
MSDS Num: CLGFH
MSDS NAME: PRISM ? 454 SURF-INSENSIT GEL INST ADH
Responsible Party
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
Info Phone: 860-571-5100
Emergency Phone Number: 860-571-5100
Preparer's Name: RYAN MICKELSON
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORPORATION
Address: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT 06067-3910
Phone: 860-571-5100
=======================================================
Item Description Information
=======================================================
=======================================================
Ingredients
=======================================================
Cas: 7085-85-0
RTECS #: UD3330000
Name: ETHYL CYANOACRYLATE
% low Wt: 85.
% high Wt: 90.
------------------------------
Cas: 9011-14-7
RTECS #: TR0400000
Name: POLY(METHYL METHACRYLATE)
% low Wt: 5.
% high Wt: 10.
------------------------------
Cas: 112945-52-5
RTECS #: VV7310000
Name: SILICA, AMORPHOUS, FUMED, CRYST.-FREE
% low Wt: 5.
% high Wt: 10.
------------------------------
Cas: 123-31-9
RTECS #: MX3500000
Name: HYDROQUINONE
% low Wt: .1
% high Wt: .5
OSHA PEL: 2 MG/M3
ACGIH TLV: 2 MG/M3
ACGIH STEL: NOT ESTABLISHED
EPA Rpt Qty: 1 LB
DOT Rpt Qty: 1 LB
=======================================================
Health Hazards Data
=======================================================
Effects of Exposure: CYANOSCRYLATE ADHESIVE IS A VERY FAST SETTING AND STRONG
ADHESIVE. IT BONDS HUMAN TISSUE INCLUDING SKIN IN SECONDS. EXPERIENCE HAS
SHOWN THAT ACCIDENTS DUE TO CYANOACRYLATES ARE HANDLED BEST BY PASSIV E,
NONSURGICAL FIRST AID. TREATMENT OF SPECIFIC TYPES OF ACCIDENTS ARE GIVEN
BELOW.
Signs And Symptions Of Overexposure: VAPOR IS IRRITATING TO EYES AND MUCOUS
MEMBRANES ABOVE TLV. PROLONGED AND REPEATED EXPOSURE TO VAPORS MAY PRODUCE
SYMPTOMS OF NON-ALLERGIC ASTHMA IN SENSITIVE INDIVIDUALS. SKIN CONTACT MAY
CAUSE BURN S. BONDS SKIN RAPIDLY AND STRONGLY. SKIN AND EYE IRRITANT.
Medical Cond Aggravated By Exposure: NONE KNOWN
First Aid: INGESTION: INGESTION IS NOT LIKELY. SEE SUPPLEMENTAL PAGE FOR
EMERGENCY PROCEDURES. INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS PERSIST,
OBTAIN MEDICAL ATTENTION. SKIN CONTACT: SOAK IN WARM WATER. SE E SUPPLEMENTAL
PAGE FOR EMERGENCY PROCEDURES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: FLOOD WITH WATER TO POLYMERIZE. SOAK UP WITH INERT
ABSORBENT.
Waste Disposal Methods: POLYMERIZE AS ABOVE. INCINERATE FOLLOWING EPA AND LOCAL
REGULATIONS.
Handling And Storage Precautions: STORE AT OR BELOW 75 DEG F. AVOID CONTACT
WITH SKIN AND EYES. AVOID BREATHING VAPOR.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 150-200 DEG F
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL
Fire Fighting Procedures: NOT AVAILABLE
Unusual Fire/Explosion Hazard: NONE
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT AVAILABLE
Ventilation: POSITIVE DOWN DRAFT EXHAUST VENTILATION SHOULD BE PROVIDED TO
MAINTAIN VAPOR CONCENTRATION BELOW TLV
Protective Gloves: NITRILE OR POLYEHTYLENE GLOVES AND APRONS. DO NOT USE
COTTON.
Eye Protection: SAFETY GLASSES OR GOGGLES.
=======================================================
Physical/Chemical Properties
=======================================================
Boiling Point: >148.9C, 300.F
Vapor Pres: < 0.2MM
Vapor Density: 3
Spec Gravity: 1.05
Solubility in Water: POLYMERIZED BY WATER
Percent Volatiles by Volume: 85.4
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NOT AVAILABLE
Materials To Avoid: POLYMERIZED BY CONTACT WITH WATER, ALCOHOLS, AMINES,
ALKALIES.
Hazardous Decomposition Products: NONE
=======================================================
Toxicological Information
=======================================================
Toxicological Information: ESTIMATED ORAL LD50 MORE THAN 5000 MG/KG. ESTIMATED
DERMAL LD50 MORE THAN 2000 MG/KG
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PRISM ? 454 SURF-INSENSIT GEL INST ADH
Company: LOCTITE CORPORATION
Street: 1001 TROUT BROOK CROSSING
City: ROCKY HILL CT
Zipcode: 06067-3910
Health Emergency Phone: 860-571-5100
Label Required IND: Y
Date Of Label Review: 07/02/2001
Status Code: A
Origination Code: G
Hazard And Precautions: CYANOSCRYLATE ADHESIVE IS A VERY FAST SETTING AND
STRONG ADHESIVE. IT BONDS HUMAN TISSUE INCLUDING SKIN IN SECONDS. EXPERIENCE
HAS SHOWN THAT ACCIDENTS DUE TO CYANOACRYLATES ARE HANDLED BEST BY PASSIV E,
NONSURGICAL FIRST AID. TREATMENT OF SPECIFIC TYPES OF ACCIDENTS ARE GIVEN
BELOW.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.