DEXTER ELECTRONIC MATERIALS DI -- HYSOL HD5020 (CATALYST 20 OR CATALYST A
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CLFLL
MSDS NAME: HYSOL HD5020 (CATALYST 20 OR CATALYST A
Kit Part: Y
Responsible Party
Name: DEXTER ELECTRONIC MATERIALS DIV, THE DEXTER CORP.
Address: 15051 DON JULIAN ROAD
Box: 1282
City: INDUSTRY CA 91749-1282
Info Phone: 818-968-6511
Emergency Phone Number: 818-916-9107
Chemtrec IND/Phone: (800)424-9300
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DEXTER CORP DEXTER ELECTRONIC MATERIALS DIV
Address: 15051 E DON JULIAN RD
City: LA PUENTE CA 91746
Phone: 818-968-6511
=======================================================
Ingredients
=======================================================
Cas: 90-72-2
RTECS #: SN3500000
Name: 2,4,6-TRI (DIMETHYLAMINO)METHYL PHENOL
% low Wt: 35.
% high Wt: 60.
------------------------------
Cas: 112-57-2
RTECS #: KH8585000
Name: TETRAETHYLENE PENTAMINE
% low Wt: 15.
% high Wt: 35.
------------------------------
Cas: 111-76-2
RTECS #: KJ8575000
Name: ETHYLENE GLYCOL MONOBUTYL ETHER
% low Wt: 15.
% high Wt: 35.
OSHA PEL: 240 MG/M3;50 PPM
ACGIH TLV: 121 MG/M3;25 PPM
ACGIH STEL: NOT ESTABLISHED
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50 RATS: 470 MG/KG
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: TARGET ORGANS: BLOOD, LUNG, LIVER & KIDNEY. EYES:
SEVERELY IRRITATING. MAY CAUSE CORNEAL INJURY WHICH MAY RESULT IN PERMANENT
IMPAIRMENT OF VISION, EVEN BLINDNESS. SKIN: SEVERELY IRRITATING. MAY CAUS E
DELAYED ALLERGIC SKIN REACTION. MAY CAUSE BURNS. MAY BE ABSORBED IN HARMFUL
AMOUNTS. INHALATION: VAPOR/MIST CAN IRRITATE THE UPPER RESPIRATORY TRACT.
INGESTION: SINGLE DOSE ORAL TOXICITY IS LOW. INGESTION MAY CAUSE
GASTROINTESTINAL IRRITATION OR ULCERATION. MAY CAUSE BURNS OF THE MOUTH AND
THROAT.
First Aid: INHALATION: MOVE SUBJECT TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION
IF BREATHING HAS STOPPED. CALL A PHYSICIAN. EYES: IMMEDIATELY FLUSH WITH A
LARGE AMOUNT OF WATER FOR 30 MIN. CONSULT MEDICAL PERSONN EL. SKIN:
IMMEDIATELY FLUSH SKIN WITH A LARGE AMOUNT OF WATER FOR AT LEAST 15 MIN. GET
PROMPT MEDICAL ATT'N & WASH WITH SOAP & WATER. REMOVE AND WASH
CONTAMINATED CLOTHING. INGESTION: DO NOT INDUCE VOMITING. GIVE LARGE
QUANTITIES OF WATER TO DILUTE MATERIAL, & TRANSPORT TO A MEDICAL
FACILITY.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE IGNITION SOURCES. PROVIDE ADEQUATE
VENTILATION. COVER SPILL WITH ABSORBENT MATERIAL AND REMOVE TO WASTE
CONTAINER.
Waste Disposal Methods: SHOULD BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
ENVIRONMENTAL CONTROL REGULATIONS.
Handling And Storage Precautions: STORE IN CLOSED CONTAINERS IN A COOL, DRY
AREA AWAY FROM HEAT. USE ONLY WITH ADEQUATE VENTILATION.
Other Precautions: AVOID PROLONGED OR REPEATED BREATHING OF VAPORS OR CONTACT
WITH SKIN.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point: =68.3C, 155.F
Lower Limits: N/E
Upper Limits: N/E
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICALS, FOAM, WATER SPRAY OR FOG.
Fire Fighting Procedures: PERSONNEL ENGAGED IN FIRE FIGHTING SHOULD WEAR
SELF-CONTAINED BREATHING APPARATUS TO GUARD AGAINST POSSIBLE HARMFUL FUMES.
Unusual Fire/Explosion Hazard: N/E
=======================================================
Control Measures
=======================================================
Respiratory Protection: WEAR A PROPERLY FITTED NIOSH/MSHA APPROVED
SELF-CONTAINED BRATHING APPARATUS OR INDUSTRIAL TYPE CANISTER MASK IN
ENCLOSED AREAS WITH POOR OR NO VENTILATION SYSTEM. IF AIR CONTAMINATION IS
SUSPECTED, T HE CONTAMINATION SHOULD BE VARIFIED BY AIR MONITORING BEFORE
SELECTION OF RESPIRATOR PROTECTION EQUIPMENT IS MADE.
Ventilation: LOCAL EXHAUST PREFERRED. MECHANICAL ACCEPTABLE.
Protective Gloves: HYDROCARBON INSOLUBLE RUBBER OR PLASTIC
Eye Protection: CHEMICAL GOGGLES, FACE SHIELD OR SAFETY GLASSES
Other Protective Equipment: HYDROCARBON INSOLUBLE APRONS, EYE WASH AND SAFETY
SHOWER.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: V5
Boiling Point: =171.1C, 340.F
Vapor Pres: N/E
Vapor Density: 4.07
Volatile Org Content %: 25
Spec Gravity: 0.965
PH: N/E
Solubility in Water: N/E
Appearance and Odor: AMBER LIQUID; AMINE ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HIGH TEMPERATURES AND OPEN FLAMES
Materials To Avoid: COPPER AND COPPER BASE ALLOYS, CHLORINATED ORGANIC
COMPOUNDS
Hazardous Decomposition Products: N/E
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
Toxicological Information: EXCESSIVE EXPOSURE MAY CAUSE BLOOD, LUNG, LIVER
& KIDNEY EFFECTS. OBSERVATIONS IN ANIMALS INCLUDE TESTICULAR ATROPHY ONLY
AFTER REPEATED ORAL ADMINISTRATION. TESTICULAR ATROPY HAS NOT BEEN OBSERVED
WI TH OTHER ROUTES OF EXPOSURE. BIRTH DEFECTS ARE UNLIKELY. EXPOSURES HAVING
NO EFFECT ON THE MOTHER SHOULD HAVE NO EFFECT ON THE FETUS. DID NOT CAUSE
BIRTH DEFECTS IN ANIMALS; OTHER EFFECTS WERE SEEN IN THE FETUS ONLY AT DOSES
WHICH CAUSED TOXIC EFFECTS TO THE MOTHER. RESULTS OF MUTAGENICITY TESTS IN
ANIMALS HAVE BEEN NEGATIVE. RESULTS OF IN VITRO ("TEST TUBE") MUTAGENICITY
TESTS HAVE BEEN INCONCLUS IVE.
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: ETHYLENE GLYCOL MONOBUTYL ETHER IS REPORTABLE UNDER
SARA TITLE III SECTION 313.
State Regulatory Information: 2,4,6-TRI(DIMETHYLAMINOMETHYL)PHENOL CONTAINS A
TRACE AMOUNT OF FORMALDEHYDE WHICH IS KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER (PROP 65).
=======================================================
Other Information
=======================================================
=======================================================
Transportation Information
=======================================================
Trans ID NO: 157561
MSDS NAME: HYSOL HD5020 (CATALYST 20 OR CATALYST A
MSDS Prepared Date: 06/23/1992
Review Date: 06/20/2001
Multiple KIT Number: 0
Kit Part IND: Y
Unit Of Issue: CY
Type Of Container: CYLINDER
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: HYSOL HD5020 (CATALYST 20 OR CATALYST A
Company: DEXTER CORP DEXTER ELECTRONIC MATERIALS DIV
Street: 15051 E DON JULIAN RD
City: LA PUENTE CA
Zipcode: 91746
Health Emergency Phone: 818-916-9107
Label Required IND: Y
Date Of Label Review: 06/20/2001
Status Code: A
Origination Code: F
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: TARGET ORGANS: BLOOD, LUNG, LIVER & KIDNEY. EYES:
SEVERELY IRRITATING. MAY CAUSE CORNEAL INJURY WHICH MAY RESULT IN PERMANENT
IMPAIRMENT OF VISION, EVEN BLINDNESS. SKIN: SEVERELY IRRITATING. MAY CAUS E
DELAYED ALLERGIC SKIN REACTION. MAY CAUSE BURNS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|