QUANTIC INDUSTRIES INC -- CCU 119/A IMPULSE CARTRIDGE 27759-01
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BSJJW
MSDS NAME: CCU 119/A IMPULSE CARTRIDGE 27759-01
Responsible Party
Name: QUANTIC INDUSTRIES INC
Address: 990 COMMERCIAL ST
City: SAN CARLOS CA 94070
Info Phone: 415-595-1100;408-263-5210
Emergency Phone Number: 415-599-8859
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: QUANTIC INDUSTRIES INC
Address: 990 COMMERCIAL ST
Box: 148
City: SAN CARLOS CA 94070
Phone: 415-595-1100;408-263-5210
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: THIS IS A SEALED DEVICE. IF CONTENTS DO NOT LEAK OUT THERE
IS NO HEALTH HAZARD.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHALATION: REMOVE FROM EXPOSURE. SUPPORT BREATHING (GIVE ARTIFICIAL
RESPIRATION/OXYGEN) (FP N). INGESTION: CALL MD IMMEDIATELY (FP N). SKIN:
FLUSH WITH COPIOUS AMOUNTS OF WATER (FP N). EYE: FLUSH WIT H WATER FOR AT
LEAST 15 MINUTES (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CLEAN UP SPILLS USING SOFT BRISTLE BRUSH AND
CONDUCTIVE RUBBER SHOVEL. USE CAUTION-MATERIAL IS SENSITIVE TO INITIATION
FROM SOURCES SUCH AS HEAT, FLAME, SHOCK, FRICTION, AND SPARK.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.
Handling And Storage Precautions: AVOID EXPOSURE TO HEAT OVER 160F.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: >160F,>71C
Extinguishing Media: USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS (FP N).
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: DO NOT ATTEMPT TO FIGHT FIRE-UNITS MAY DETONATE
AND RELEASE SHRAPNEL.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT REQUIRED. WEAR NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: LOCAL EXHAUST ONLY IN TEST BAY.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment: NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
Appearance and Odor: NONE.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: NO
Stability Condition To Avoid: SENSITIVE TO HEAT, FLAME: MAY DETONATE AND
RELEASE SHRAPNEL.
Materials To Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: TRACE AMOUNTS OF LEAD.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CCU 119/A IMPULSE CARTRIDGE 27759-01
Company: QUANTIC INDUSTRIES INC
Street: 990 COMMERCIAL ST
PO Box: 148
City: SAN CARLOS CA
Zipcode: 94070
Health Emergency Phone: 415-599-8859
Label Required IND: Y
Date Of Label Review: 04/16/1993
Status Code: C
Label Date: 04/16/1993
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: None
Fire Hazard: Slight
Reactivity Hazard: Slight
Hazard And Precautions: AVOID EXPOSURE TO HEAT OVER 160F. ACUTE: THIS IS A
SEALED DEVICE. IF CONTENTS DO NOT LEAK OUT THERE IS NO HEALTH HAZARD.
CHRONIC: NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.