ICI FIBERITE CORP -- MXB 7620/7781 38", 701490
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWBSX
MSDS NAME: MXB 7620/7781 38", 701490
Responsible Party
Name: ICI FIBERITE CORP
Address: 645 N CYPRESS
Box: 787
City: ORANGE CA 92666
Info Phone: 714-639-2050
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: FIBERITE
Address: 645 NORTH CYPRESS
City: ORANGE CA 92666
Phone: 714-639-2050/ 213-628-0568
Name: ICI FIBERITE CORP
Address: 645 N CYPRESS
Box: 787
City: ORANGE CA 92666
Phone: 714-639-2050
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: MAY CAUSE ALLERGIC SKIN RXN IN SENSITIVE INDIVIDUALS.
INHAL OF RESIDUAL ORG SOLV MAY BE HARMFUL. MAY CAUSE RESP IRRIT &
NARCOSIS. DUST GENERATED DURING ROUTINE HNDLG/MACHINING OF CURED MATL MAY
CAUSE MECH SKIN & EYE IRRIT. ING 1: GLASS FIBER IS INERT; HOWEVER,
ABRASIVE & IRRITANT CHARACT MAY BE NOTED (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ: AFTER PARTICULATE CNTCT
W/SKIN/MUC MEMBS OF EYES & NOSE. ING 2: EPOXY RESINS MAY CAUSE IRRIT OF
SKIN & EYES & POSS DERM OR ALLERGY/SENSIT. VAPS COMING OFF HEATED
MATL MAY CAUSE IRRIT TO EYES , NOSE & THROAT. EPOXIES ARE COMMONLY
MUTAGENIC TO BACTERIA. ING 3: EXCESS INHAL OF ACETONE VAPS CAN CAUSE (SUPDAT)
Medical Cond Aggravated By Exposure: EXISTING ALLERGIES MAY BE AGGRAVATED BY
EXPOSURE TO EPOXY RESINS.
First Aid: INGEST: CALL MD IMMEDIATELY (FP N). INHAL: REMOVE TO FRESH AIR.
PROVIDE OXYGEN IF NECESSARY. IF NOT BREATHING, GIVE MOUTH-TO-MOUTH
RESUSCITATION. CALL MD. EYES: IRRIGATE W/WATER FOR AT LEAST 15 MINUTE S. SEEK
MEDICAL ATTENTION. SKIN: WASH THOROUGHLY W/SOAP & WATER. SEEK MEDICAL
ATTENTION IF IRRITATION DEVELOPS. WASH CONTAMINATED CLOTHING BEFORE REUSE.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CONTAMINATED MATERIAL SHOULD BE PICKED UP AND
DISPOSED OF PROPERLY.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS. QUESTIONS CONCERNING DISPOSAL SHOULD BE DIRECTED TO
MANUFACTURER'S SAFETY, HEALTH & ENVIRONMENTAL AFFAIRS DEPARTMENT FOR
EVALUATION ON A CASE-BY-CASE BASIS.
Handling And Storage Precautions: STORE AT OR BELOW 40F.
Other Precautions: THE USE OF GLOVES WHEN HANDLING UNCURED MATERIAL IS
RECOMMENDED. AVOID SKIN CONTACT. WHEN PROCESSING AT ELEVATED TEMPERATURES,
PROVIDE ADEQUATE VENTILATION TO CONTROL PROCESSING FUMES & VAPORS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL, WATER.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). DISSIPATE HEAT BY SPREADING MATL APART & DOUSING
W/WATER. CONTAIN EMISSIONS USING LOC EXHST.
Unusual Fire/Explosion Hazard: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USUALLY NOT NEEDED. USE NIOSH/MSHA APPRVD RESP IF EXPOS
LIMITS ARE EXCEEDED. IN ABSENCE OF ADEQ GENERAL OR LOCAL VENT, PROVIDE
NIOSH/MSHA APPRVD RESPS TO MINIMIZE EXPOS TO GAS, VAPS OR FUMES RELEASED
DURING LAY UP OR MOLDING OPERATIONS.
Ventilation: PROVIDE GOOD GEN &/OR LOC EXHST VENT TO CONTROL AIRBORNE
LEVELS BELOW EXPOS LIMS, PARTICULARLY WHERE GRINDING (SUPDAT)
Protective Gloves: IMPERVIOUS GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: USE CLEAN BODY-COVERING CLOTHING TO PREVENT
EXPOSURE.
Work Hygienic Practices: IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE, HANDLE
WITH CARE AND AVOID UNNECESSARY PERSONAL CONTACT.
Supplemental Safety and Health: EFTS OF OVEREXP: NASAL & RESP IRRIT, HDCH,
CNS DEPRESS & NARCOSIS. VENT: OR HEATING OPERATIONS OCCUR.
=======================================================
Physical/Chemical Properties
=======================================================
Spec Gravity: 1.5-2.2
Appearance and Odor: IMPREGNATED FIBERS; SLIGHT CHARACTERISTIC ODOR.
Percent Volatiles by Volume: <2
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG ACIDS, STRONG BASES, STRONG OXIDIZERS.
Hazardous Decomposition Products: DENSE SMOKE, ACRID VAPORS & FUMES,
HYDROCARBONS OF VARIABLE COMPOSITION, CO*X, NO*X.
Hazardous Polymerization Indicator: YES
Conditions To Avoid Polymerization: HAZARDOUS POLYMERIZATION CAN OCCUR WITH
RAPID OR EXCESSIVE HEATING.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: MXB 7620/7781 38", 701490
Assigned IND: Y
Company: ICI FIBERITE CORP
Street: 645 N CYPRESS
PO Box: 787
City: ORANGE CA
Zipcode: 92666
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 12/01/1994
Status Code: C
Label Date: 12/01/1994
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: MAY CAUSE ALLERGIC SKIN REACTION IN SENSITIVE
INDIVIDUALS. INHALATION OF RESIDUAL ORGANIC SOLVENT MAY BE HARMFUL. MAY CAUSE
RESPIRATORY IRRITATION & NARCOSIS. DUST MAY CAUSE MECHANICAL SKIN & E
YE IRRITATION. EXCESSIVE INHALATION OF ACETONE VAPORS CAN CAUSE NASAL &
RESPIRATORY IRRITATION, HEADACHE, CNS DEPRESSION & NARCOSIS. CHRONIC:
NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.