ULTRA SCIENTIFIC -- HB-101, 2,4 D METHYL ESTER SOLUTION AT 100 (S
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWNYR
MSDS NAME: HB-101, 2,4 D METHYL ESTER SOLUTION AT 100 (SUPDAT)
Responsible Party
Name: ULTRA SCIENTIFIC
Address: 250 SMITH ST
City: N KINGSTOWN RI 02852
Info Phone: 401-294-9400
Emergency Phone Number: 401-294-9400
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: ULTRA SCIENTIFIC
Address: 250 SMITH STREET
City: NORTH KINGSTOWN RI 02852-5000
Phone: 401-294-9400
=======================================================
Ingredients
=======================================================
Cas: 67-56-1
RTECS #: PC1400000
Name: METHANOL (SARA 313) (CERCLA). LD50 (ORAL RAT):12.900 MG/KG
% Wt: 99.99
OSHA PEL: 200 PPM, S
ACGIH TLV: 200 PPM;250 STEL, C
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 1928-38-7
RTECS #: AG8810000
Name: ACETIC ACID, (2,4-DICHLOROPHENOXY)-, METHYL ESTER; (2,4 D METHYL ESTER)
% Wt: 0.013
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ING 1
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: TOXIC;IRRITANT. ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS-DIRECT PHYSICAL CONTACT SHOULD BE AVOIDED.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYES:IN CASE OF EYE/SKIN CONTACT, FLUSH WITH COPIOUS AMOUNTS OF
WATER FOR AT LEAST 15 MINUTES. INGEST:CALL MD IMMEDIATELY (FP N).
INHAL:REMOVE TO FRESH AIR-GIVE OXYGEN, IF NECESSARY. CONTACT PHYSICIAN .
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DUE TO THE SMALL QUANITITY INVOLVED, SPILLS OR LEAKS
SHOULD NOT POSE A SIGNIFICANT PROBLEM. A LEAKING BOTTLE MAY BE PLACED IN A
PLASTIC BAG AND NORMAL DISPOSAL PROCEDURES FOLLOWED. LIQUID SAMPLES MAY BE
ABSORBED ON VERMICULITE OR SAND.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: BURN IN A CHEMICAL INCINERATOR EQUIPPED WITH AN
AFTERBURNER AND SCRUBBER. OBSERVE ALL FEDERAL, STATE AND LOCAL LAWS
CONCERNING DISPOSAL.
Handling And Storage Precautions: KEEP TIGHTLY CLOSED, AND STORE IN A COOL, DRY
PLACE.
Other Precautions: THIS MATERIAL SHOULD ONLY BE USED BY THOSE PERSONS TRAINED
IN THE SAFE HANDLING OF HAZARDOUS CHEMICALS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL POWDER, OR WATER SPRAY
Fire Fighting Procedures: NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: COMBUSTIBLE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE APPROPRIATE OSHA/MSHA APPROVED SAFETY EQUIPMENT.
Ventilation: NONE SPECIFIED BY MANUFACTURER.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APP CHEM GOGS AND FSHIELD (FP N).
Other Protective Equipment: LABORATORY COAT, AND/OR RUBBER APRON.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: MFR TRADE NAME/PART #:UG/ML IN METHANOL.
=======================================================
Physical/Chemical Properties
=======================================================
Evaporation Rate & Reference: NOT KNOWN
Solubility in Water: NOT KNOWN
Appearance and Odor: LIQUID.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZERS
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: HB-101, 2,4 D METHYL ESTER SOLUTION AT 100 (SUPDAT)
Company: ULTRA SCIENTIFIC
Street: 250 SMITH STREET
City: NORTH KINGSTOWN RI
Zipcode: 02852-5000
Health Emergency Phone: 401-294-9400
Label Required IND: Y
Date Of Label Review: 01/30/1995
Status Code: C
Label Date: 01/30/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE: TOXIC:IRRITANT. ALL CHEMICALS
SHOULD BE CONSIDERED HAZARDOUS-DIRECT PHYSICAL CONTACT SHOULD BE AVOIDED.
CHRONIC:NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.