ITW FLUID PRODUCTS -- SAFETAP ULTIMA
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWNWX
MSDS NAME: SAFETAP ULTIMA
Responsible Party
Name: ITW FLUID PRODUCTS
Address: 8501 DELPORT DR
City: ST LOUIS MO 63114
Info Phone: 410-342-9225
Emergency Phone Number: 800-443-9536
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: ITW DYKEM/ DYMON
Address: 805 E OLD 56 HWY
City: OLATHE KS 66061
Phone: 800-443-9536
Name: ITW FLUID PRODUCTS GROUP
Address: 8501 DELPORT DRIVE
City: ST LOUIS MO 63114
Phone: 800-443-9536
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: NONE EXPECTED; HOWEVER, LIKE ANY INDUSTRIAL CHEMICAL
PRODUCT, EXERCISE CARE TO AVOID EXCESSIVE EXPOSURE TO SAFETAP.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INGEST:CALL MD IMMEDIATELY (FP N). INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) (FP N). EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD (FP N).
SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: NO SPECIAL PROTECTIVE EQUIPMENT IS REQUIRED FOR
CLEANUP PERSONNEL. STOP SPILL AT SOURCE AND DIKE AREA TO PREVENT SPREADING.
PUMP LIQUID TO SALVAGE TANK. ABSORB REMAINING LIQUID ON ABSORBENT MATERIAL A
ND SHOVEL INTO A SUITABLE CONTAINER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: INCINERATION IS RECOM DISP METH FOR ALL NON-HAZ CHEM
WASTE, ALTHOUGH MATL MAY BE LANDFILLED IN ACCORD WITH ALL APPLIC FEDERAL,
STATE AND LOCAL REGS. THIS PROD, IF DISPOSED OF, IS NOT CONSIDERED A HAZA
RDOUS WASTE UNDER CURRENT FEDERAL REGULATIONS.
Handling And Storage Precautions: SAFETAP IS NOT KNOWN NOR EXPECTED TO BE
HAZARDOUS, BUT AS WITH ALL INDUSTRIAL CHEMICAL PRODUCTS, EXERCISE CAUTION IN
THE USE AND HANDLING OF SAFETAP.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: PMCC
Flash Point Text: >300F,>149C
Extinguishing Media: DRY CHEMICAL, WATER FOG, REGULAR FOAM.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). WATER OR FOAM MAY CAUSE FROTHING WHICH CAN BE VIOLENT, ESP IF SPRAYED
INTO CNTNRS OF HOT BURNING LIQUID.
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N). NO PROTECTION REQUIRED.
Ventilation: NO PROTECTION REQUIRED.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >425F,>218C
Vapor Pres: <1MMHG@68F
Vapor Density: HVR/AIR
Spec Gravity: 0.94 @ 68F
PH: 6-7
Solubility in Water: INSOLUBLE
Appearance and Odor: BLUE VISCOUS LIQUID
Percent Volatiles by Volume: <1/10
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZING AGENTS WILL CAUSE A VIGOROUS REACTION.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SAFETAP ULTIMA
Company: ITW FLUID PRODUCTS GROUP
Street: 8501 DELPORT DRIVE
City: ST LOUIS MO
Zipcode: 63114
Health Emergency Phone: 800-443-9536
Label Required IND: Y
Date Of Label Review: 01/25/1995
Status Code: C
Label Date: 01/25/1995
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: None
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE & CHRONIC:NONE SPECIFIED BY
MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.