===================== Product Identification =====================
MSDS NAME:WHITE GELCOAT, GV42000
NIIN:00N019327
MSDS Number: BLGND
=== Responsible Party ===
Company:FERRO CORPORATION
Address:1301 N FLORA ST
City:PLYMOUTH
State:IN
ZIP:46563
Country:US
Info Phone Num:219-935-5131
Emergency Phone Num:800-424-9300 (CHEMTREC)
Preparer's Name:KKR
CAGE:0LG38
=== Contractor Identification ===
Company:FERRO CORP
Address:1301 N FLORA ST
Box:City:PLYMOUTH
State:IN
ZIP:46563-1344
Country:US
Phone:219-935-5131
CAGE:7L115
Company:FERRO CORPORATION
Address:27 CASTILIAN DR
City:SANTA BARBARA
State:CA
ZIP:93117-3092
Country:US
Phone:805-968-5000
CAGE:0LG38
============= Composition/Information on Ingredients =============
Name:ING 13:SHOULD ALWAYS BE PREMIXED SEPARATELY INTO PROD.
NEVER MIX PROMOTERS AND CATALYST DIRECTLY TOGETHER.
RTECS #:9999999ZZ
Name:EYE PROT:ADD FULL LENGTH FACESHIELD TO GOGGLES .
RTECS #:9999999ZZ
Name:STYRENE, MONOMER (SARA III)
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: 32.71%
OSHA PEL:100 PPM
ACGIH TLV:S,50PPM/100STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 12%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 15%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Name:SILICA, AMORPHOUS FUMED (MFR CAS #7631-86-9)
CAS:112945-52-5
RTECS #:VV7310000
Fraction by Wt: 1.80%
OSHA PEL:6 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Name:METHYL METHACRYLATE (SARA III)
CAS:80-62-6
RTECS #:OZ5075000
Fraction by Wt: 3%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:ACETOACETIC ACID, METHYL ESTER; (METHYL ACETOACETATE).
VP:1.0 @ 68F.
CAS:105-45-3
RTECS #:AK5775000
Fraction by Wt: .10%
Name:SUPP DATA:EXCESSIVE QTYS OF TALC CAN RESULT IN SCARRING OF
LUNGS OR IN COVERING OF LUNGS. GROSSLY EXCESSIVE &(SEE ING 8)
RTECS #:9999999ZZ
Other REC Limits:NOT RELEVANT
Name:ING 7:& PRLNGD EXPOS TO TITIANIUM DIOXIDE MAY LEAD TO PULM
FIBROSIS. ONE STUDY OF TITANIUM DIOXIDE INHALATION(SEE ING 9)
RTECS #:9999999ZZ
Name:ING 8:IN RATS REVEALED SIGNIFICANT INCR IN BENIGN &
MALIGNANT LUNG TUMORS @ 250 MG/M3. THIS EFT WAS NOT (SEE ING 10)
RTECS #:9999999ZZ
Name:ING 9:OBSERVED AT LOW LEVELS. NORMAL CLEARANCE MECH OF
LUNGS MAY HAVE BEEN OVERWHELMED @ HIGH LEVEL & (SEE ING 11)
RTECS #:9999999ZZ
Name:ING 10:CONTRIBUTED TO THE OCCURENCE OF CARCINOGENICITY.
RTECS #:9999999ZZ
Name:FIRST AID PROC:NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON.
RTECS #:9999999ZZ
Name:OTHER PREC:(METAL ORGANICS SUCH AS COBALT OR ANALINE TYPE)
& CATALYST (ORGANIC PEROXIDE TYPE) USED W/PROD, (SEE ING 14)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:CAN CAUSE SEVERE IRRIT W/BURNING
SENSATION. MAY CAUSE MECH IRRIT. SKIN:MAY CAUSE IRRIT, DERM. SKIN
ABSORPTION OF STYRENE CAN OCCUR TO SIGNIFICANTLY INCR OVEREXP FROM
OTHER ROUTES OF ENTRY. INHAL:O VEREXP TO STYRENE & MMA CAUSES IRRIT
TOALL PARTS OF RESP TRACT. HIGH LEVELS CAN CAUSE ANESTHETIC (EFTS
OVEREXP)
Explanation of Carcinogenicity:STYRENE: GROUP 2B (IARC).
Effects of Overexposure:HLTH HAZ:EFTS & CNS DEPRESS. MAY BE FATAL AT
10,000 PPM STYRENE. ALLERGIC RESP REACTIONS MAY BE POSS. EXCESSIVE
EXPOS TO TALC MAY CAUSE BRONCHIAL IRRIT (BRONCH). MAY CAUSE MECH
IRRIT. INGEST: CAUSES G I IRRIT & WILL CONTRIBUTE TO SYS EFTS.
CHRONIC:PRLNGD/RPTD CONTACT MAY CAUSE DERM &/OR ALLERGIC REACTIONS.
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH PROMPTLY W/LOTS OF WATER FOR AT LEAST 15 MINUTES
AND GET MD IMMED. SKIN:WASH THOROUGHLY. SEE MD IF IRRIT IS PRESENT
OR PERSISTS. SKIN:WASH THORO. SEE MD IF IRRIT IS PRESENT OR
PERSISTS. INHA L:REMOVE TO VENT AREA. MAKE COMFORTABLYWARM BUT NOT
HOT, USE O2 OR ARTF RESP AS REQ. SEE MD IF IRRIT IS
PRESENT/PERSISTS. INGEST:CALL MD IMMED.ONLY INDUCE VOMIT AT
INSTRUCTIONS OF MD.(SEE ING 12)
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:85.0F,29.4C
Lower Limits:1.1%
Upper Limits:8.2%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:HIGHLY FLAMM. CAN POLYMERIZE WHEN HEATED.
SEALED CNTNRS CAN RUPTURE EXPLOSIVELY WHEN HEATED. COMUSTION CAN
PRODUCE TOX GASES. TREAT AS OIL FIRE. (SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AREA
AND MAINTAIN VENTILATION. USE DESCRIBED PROTECTIVE MEASURES. USE
ABSORBENT MATERIAL, SUCH AS CLAY OR SAND, TO COLLECT AND CONTAIN
FOR SALVAGE AND DISPOSA L.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN CLOSED CONTAINERS AWAY FROM
SUNLIGHT, HEAT, FLAMES & SPARKS. STORE BELOW 100F, 60-80F
PREFERRED. DO NOT STORE NEAR FOOD OR FEED.
Other Precautions:DO NOT CUT, PUNCTURE, OR WELD ON OR NEAR CNTNR. SINCE
EMPTY CNTNRS RETAIN PROD RESIDUE, CONTINUE TO FOLLOW PRECS & HNDLG
SHOWN ON MSDS. AVOID IMPROPER ADDITION OF PROMOTER &/OR CATALYST.
CONSULT PROD BULLETIN. PROMOTERS (SEE INGRED 13)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IN THE ABSENCE OF PROPER VENTILATION USE NIOSH/
MSHA APPROVED RESPIRATOR.
Ventilation:VENTILATE TO MAINTAIN EXPOSURE BELOW PUBLISHED EXPOSURE
LIMITS. USE EXPLOSION PROOF MOTORS & WIRING.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOG, MAY(SEE ING 15)
Other Protective Equipment:EYE WASH STATION WITHIN 10 SECONDS OF WORK
STATION. WHERE SPLASH CAN OCCUR, USE AN APRON.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
EXPLO HAZ:VAPS ARE HEAVIER THAN AIR. CAN TRAVEL ALONG GROUND OR THROUGH
VENT SYS, BE IGNIT BY SPARKS/FLAMES/STATIC. WATER MAY BE USED TO
KEEP FIRE-EXPOSED CNTNRS COOL UNTIL FIRE IS OUT. EFTS OF OVEREX
P:PRLNGD OVEREXP CAN CAUST SYMPS OF NAUS, HDCH, VOMIT, LOSS OF
APPETITE, & GEN WEAKNESS. PRLNGD EXPOS TO (SEE INGRED 7)
================== Physical/Chemical Properties ==================
HCC:F4
Vapor Density:HVR/AIR
Spec Gravity:1.3
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NONE
Appearance and Odor:LIQUID WITH STYRENE ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES, AND OTHER OXIDIZING AGENTS.
Stability Condition to Avoid:CONSIDERED STABLE AT ROOM TEMPERATURE.
Hazardous Decomposition Products:OXIDES OF CARBON, TITANIUM AND
ALUMINUM; INCOMPLETELY BURNED HYDROCARBONS.
Conditions to Avoid Polymerization:SUNLIGHT, HEAT, FLAMES, SPARKS,
CONTAMINATION, PROLONGED STORAGE ABOVE 100F.
==================== Disposal Considerations ====================
Waste Disposal Methods:PACKAGE IN DOT APPROVED CONTAINERS AND TRANSPORT
TO EPA APPROVED TREATMENT, STORAGE, AND DISPOSAL (TSO) FACILITY.
DISPOSAL MUST BE IN ACCORDANCE WITH ALL LOAL, STATE AND FEDERAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
| ALL PAGES On Chemical Property IN THIS GROUP
| | NAME | CAS |
BEXANE PT B, 4032
| 111-40-0 112-24-3 112-57-2 |
|
CUT-THRU, 1740
| 5989-27-5 107-41-5 |
|
WHITE GELCOAT, GV42000
| 100-42-5 13463-67-7 14807-96-6 112945-52-5 80-62-6 105-45-3 |
|
BIOGUARD BALANCE PAK 200
| 497-19-8 |
|
BIOGUARD SPA PH INCREASER
| 497-19-8 |
|
BIOGUARD SPA PH DECREASER
| 7681-38-1 |
|
BIOGUARD LO'N SLO
| 7681-38-1 |
|
BIOGUARD SPA POLISH
| 57-55-6 102-71-6 |
|
DURA SLIDE LUBRICANT AEROSOL
| 106-97-8 79-01-6 71-55-6 |
|
NAVOSOL 300
| 64742-95-6 |
|
AMMONIUM SULFATE
| 7783-20-2 |
|
VARATHANE PROFESSIONAL CLEAR FINISH, (SUPP
| 8052-41-3 64742-95-6 75-09-2 75-28-5 74-98-6 |
|
VARATHANE PROFESSIONAL CLEAR FINISH, (SUPP
| 75-28-5 74-98-6 8052-41-3 64742-95-6 75-09-2 |
|
VARATHANE PROFESSIONAL CLEAR FINISH, (SUPP
| 8052-41-3 64742-95-6 75-09-2 75-28-5 74-98-6 |
|
VARATHANE PROFESSIONAL CLEAR FINISH,GLOSS,(
| 8052-41-3 |
|
VARATHANE PROFESSIONAL CLEAR FINISH GLOSS,(
| 8052-41-3 |
|
VARATHANE PROFESSIONAL CLEAR FINISH GLOSS,(
| 8052-41-3 |
|
FLEXGEL, 103919387
| 64741-88-4 |
|
NATURAL OIL FINISH SUPER BUILD, SB 66
| 8052-41-3 |
|
LIQUID PLASTIC EXT SUPER BUILD, SB 92
| 8052-41-3 71-36-3 64742-81-0 |
|
SYNKO TUFF PATCH SMOOTH AND TEXTURED, 380
| 85-68-7 |
|
MANCHEM APG
| 125904-15-6 57-55-6 7647-01-0 |
|
WATER-BORNE TRAFFIC PAINT-WHITE
| 1317-65-3 64-17-5 67-56-1 57-55-6 13463-67-7 14464-46-1 |
|
SUM KOOL
| |
|
NATROSOL
| 5989-27-5 26027-38-3 |
|
13600 CUPRIC OXIDE
| 7440-50-8 |
|
LUBRICATING AGENT 2970
| |
|
GV-55313 BURNT SIENNA POLYPASTE
| |
|
DAP WELDWOOD ORIGINAL CONTACT CEMENT
| 71-55-6 64742-89-8 108-88-3 |
|
PK-7535 RED CHEM-O-SOL
| 1309-64-4 |
|
R3580 YELLOW CHEM-O-SOL
| 117-81-7 |
|
RED-Z
| 7778-54-3 9003-04-7 |
|
TRU-TEST SUPREME WOODSMAN SANDING SEALER, 0
| 64742-47-8 8032-32-4 557-05-1 |
|
KWIK KLEEN
| 7647-01-0 |
|
KEROSENE (TAC)
| 8008-20-6 |
|
GLO-COAT, 10110-58-59
| 111-90-0 8002-74-2 7732-18-5 |
|
PIGMENTED OIL WALLBOARD SEALER, TT-S-179B
| 8052-41-3 |
|
SLM-ST SILVERMASTER STABILIZER, 60-18609-00
| |
|
ED-305L
| |
|
PROFORMER
| 1330-20-7 14464-46-1 71-55-6 |
|
TURBO T OIL 100, 65607
| 64742-54-7 64742-70-7 64742-57-0 |
|
GALVAPREP 5
| 13598-37-3 13138-45-9 7697-37-2 |
|
T-64P TONER FOR COPIER BD-7610
| 9003-07-4 1333-86-4 24937-78-8 |
|
ION-420/LC
| |
|
POLYESTER RESIN R88-27 SURFACING RESIN (SUP
| 100-42-5 |
|
EPOXY RESIN
| 25068-38-6 |
|
OROSENE 999 BRIGHTENER
| 14931-83-0 34831-03-0 |
|
ARDROX 6440
| |
|
COPPER OXIDE
| 7440-50-8 |
|
ACRYLIC SEALER 561, ASL 010
| 64741-41-9 1330-20-7 |
|
|