Effects of Overexposure:DEPRESSES CNS;IRRITATS RESPIR TRAC.HIGH CONCS
CAUSE CARDIAC ARRYTHMIA,ASPHYXIATION AND DEATH.
======================= First Aid Measures =======================
Eyes:FLUSH W/WATER.15 MIN.SKIN:WASH WITH SOAP &
WATER.INHALED:REMOVE TO FRESH AIR.GIVE CPR/OXYGEN IF NEED.DO NOT
GIVE ADRENALIN NOR ANY STIMULANT.INGESTION:GAS AT AMBIENT
TEMPERATURE-N/A.GET MEDICAL A TTN.
===================== Fire Fighting Measures =====================
Extinguishing Media:PRESENCE IN FIRE DOES NOT HINDER USE OF ANY
STANDARD MEDIUM.
Fire Fighting Procedures:SELF-CNTND BRTHG APP.H*2O TO DISPERS
VAPORS/COOL EXPOSD CONT
Unusual Fire/Explosion Hazard:CONTACT W REACTV METALS(MOLTEN AL;BA/LI
FINES) WILL PRODUCE RAPID EXOTHERMIC REACTIONS.
Spill Release Procedures:ELIMINATE IGNITION SOURCES.ISOLATE AREA.KEEP
UPWIND.IF LARGE QUANTITY IS RELEASED,ALLOW TO DISSIPATE.NOTE TLV.
====================== Handling and Storage ======================
Handling and Storage Precautions:CONTACT OF COLD LIQUID WITH SKIN MAY
PRODUCE FROST BITE. CONTACT WITH EYES CAN CAUSE SERIOUS
DAMAGE.AVOID HEAT EXCESS.PROTECT FROM PHYSICAL DAMAGE.
Other Precautions:HALOCARBONS IN CLOSED/CONFINED AREAS REQUIRE
WELL-VENTILATED DRAFT AS THEY READILY VAPORIZE AND DEPLETE/REPLACE
OXYGEN WHICH IS VITAL TO SURVIVAL.
Respiratory Protection:NOT REQD IN WELL VENTILATED AREAS.
Ventilation:LOCAL EXHAUST AT FILLING ZONES.MECHANICAL AT STORAGE AREAS.
Protective Gloves:PVC/NEOPRENE
Eye Protection:CHEM.SAFETY GOGGLES.
Supplemental Safety and Health
HCC:G3
Boiling Pt:B.P. Text:9.6F
Vapor Pres:35
Vapor Density:3.31
Spec Gravity:1.281
Evaporation Rate & Reference:HIGH
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS AND PRACTICALLY ODORLESS.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HIGH TEMPERATURE
Hazardous Decomposition Products:HALOGENS,HALIDE ACIDS, CARBONYL
HALIDES AT HIGH TEMPERATURE.
Waste Disposal Methods:FOR MODERATE QUANTITIES,PERMIT TO EVAPORATE IN
AIR AT SLOW RATE NOT TO EXCEED TLV.FOR LARGE QUANTITIES,MOVE TO
ISOLATED AREA AND ALLOW TO DISSIPATE IF REGIONAL REGULATIONS
ALLOW.DISPOSAL CONTRACTOR MA Y HAVE TO BE CONTACTED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.