===================== Product Identification =====================
MSDS NAME:EAS-6 PART A
NIIN:00N067107
Kit Part:Y
MSDS Number: CBWMK
=== Responsible Party ===
Company:QCM CO
Address:930 S CENTRAL AVE
City:KENT
State:WA
ZIP:98032
Country:US
Info Phone Num:206-872-8877
Emergency Phone Num:206-872-8877
Preparer's Name:ROY WHEDDON
CAGE:0L872
=== Contractor Identification ===
Company:Q C M CO
Address:930 CENTRAL AVE S
Box:City:KENT
State:WA
ZIP:98032-6105
Country:US
Phone:253-859-0933, FAX 253-859-0935
CAGE:8L872
Company:QCM CO
Address:930 S CENTRAL
Box:City:KENT
State:WA
ZIP:98032
Country:US
Phone:206-859-0933
CAGE:0L872
============= Composition/Information on Ingredients =============
Name:EPOXY RESIN
Fraction by Wt: 67.0%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 4.9%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Name:TALC, CONTAINING ASBESTOS FIBERS; (SILICA/TALC)
RTECS #:WW2700000
Fraction by Wt: 25%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ASBESTOS; (ASBESTOS FIBERS)
CAS:1332-21-4
RTECS #:CI6475000
Fraction by Wt: 3.1%
OSHA PEL:N/K
ACGIH TLV:N/K
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE:POSSIBLE IRRITATION AND
SENSITIZATION. CHRONIC:NONE LISTED BY MANUFACTURER.
Explanation of Carcinogenicity:ASBESTOS:IARC MONO, SUPP, VOL 7, PG 106,
1987:GROUP 1. OSHA REGULATED CFR 29 1910.1008. NTP 7TH ANNUAL RPT
ON (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:CONSULT PHYSICIAN. EYE:FLUSH WITH WATER FOR AT LEAST 15
MINUTES. SKIN:WASH WITH SOAP & WATER. DISCARD CLOTHING.
INHAL:REMOVE TO FRESH AIR. OXYGEN & ARTIFICIAL RESPIRATION IF
NECESSARY. INGEST:IF CONSC IOUS, GIVE WATER OR MILK & INDUCE
VOMITING.
===================== Fire Fighting Measures =====================
Flash Point:>350F,>177C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER MIST.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. ABSORB ON
COMBUSTIBLE MATERIAL FOR PROPER DISPOSAL. FLUSH CONTAMINATED AREAS
WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:MAY CAUSE IRRITATION. AVOID CONTACT
WITH EYES OR PROLONGED CONTACT WITH SKIN. IN CASE OF SKIN CONTACT,
FLUSH WITH PLENTY OF WATER. WASH WITH SOAP.
Other Precautions:CLOTHING-WASH BEFORE RE-USE. STORE CONTAINERS BETWEEN
50 AND 95F.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
RECOMMENDED.
Ventilation:LOCAL EXHAUST:IF INDOORS. MECHANICAL:IF INDOORS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCIN. 1994:KNOWN TO BE CARCINOGENIC.
================== Physical/Chemical Properties ==================
Spec Gravity:1.21 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE PASTE.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS; ACIDS & BASES.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:CARBON MONOXIDE AND/OR CARBON DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:INCINERATION UNDER APPROVED CONDITIONS. DISPOSAL
MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|