===================== Product Identification =====================
MSDS NAME:BI-CHEM ACCEL II-50
NIIN:00F051622
MSDS Number: CCFKZ
=== Responsible Party ===
Company:SYBRON CHEMICALS INC BIOCHEMICAL DIV
Address:111 KESLER MILL RD
Box:808
City:SALEM
State:VA
ZIP:24153-4452
Country:US
Info Phone Num:703-389-9361
Emergency Phone Num:703-389-9361
CAGE:76465
=== Contractor Identification ===
Company:SYBRON BIOCHEMICAL
Address:111 KESSLER HILL RD
Box:City:SALEM
State:VA
ZIP:24153-4452
Country:US
Phone:703-389-9361
CAGE:32511
Company:SYBRON CHEMICALS INC,SUB OF SYBRON CORP
Address:BIRMINGHAM RD
Box:66
City:BIRMINGHAM
State:NJ
ZIP:08011
Country:US
Phone:609-893-1100
CAGE:76465
============= Composition/Information on Ingredients =============
Name:AMMONIUM CHLORIDE * 96-3 *
CAS:12125-02-9
RTECS #:BP4550000
Fraction by Wt: 75-85%
OSHA PEL:10 MG/CUM
ACGIH TLV:10 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:AMMONIUM HYDROGEN PHOSPHATE, AMMONIUM PHOSPHATE (DIBASIC),
DIAMMONIUM PHOSPHATE *96-3*
CAS:7783-28-0
Fraction by Wt: 15-25%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: AMMONIUM SALTS: MAY CAUSE
GASTRIC IRRITATION. LARGE DOSES (>6 GMS) MAY CAUSE SYSTEMIC AMMONIA
TOXICITY. EYES: IRRITATION & CORNEAL INJURY, CONJUNCTIVITIS. SKIN:
IRRITATION/DERMATITIS. INHAL ATION: CAN CAUSE IRRITATION OF THE
MOUTH, NOSE & THROAT. SEVERE EXPOSURE MAY CAUSE DELAYED PULMONARY
EDEMA, IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:AMMONIUM SALTS: NAUSEA, VOMITING, IRRITATION,
HEAVY BREATHING, BLUE SKIN, DULLNESS, RESTLESSNESS, CONVULSIONS,
COMA, REDNESS, WHEEZING, CHEST PAINS
======================= First Aid Measures =======================
First Aid:SKIN: WASH MATERIAL OFF W/PLENTY OF SOAP & WATER. EYES:
IMMEDIATELY FLUSH W/PLENTY OF WATER FOR 15 MINS. INGESTION: TREAT
SYMPTOMATICALLY & SUPPORTIVELY. GIVE CPR IF NEEDED. INHALATION:
REMOVE TO FRES H AIR. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Extinguishing Media:DRY CHEMICAL, WATER SPRAY, CO2
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS W/FULL
FACEPIECE OPERATED IN PRESSURE-DEMAND/OTHER POSITIVE PRESSSURE
MODE. KEEP UPWIND.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR EYE/SKIN/RESPIRATORY PROTECTION. SWEEP UP
& RECOVER/MIX MATERIAL W/MOIST ABSORBENT & SHOVEL INTO WASTE
CONTAINER. DIG A PIT/POND/LAGOON/HOLDING AREA, CONTAIN LIQUID/SOLID
MATERIALS. WATER SPILL: NEUTRALIZE TO PH7. (SEE SUPP)
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID HANDLING WHICH WOULD CREATE
LARGE AMOUNTS OF DUST. TO MAINTAIN SHELF-LIFE, AVOID PROLONGED
EXPOSURE TO HIGH/LOW TEMPS & HUMIDITY.
Other Precautions:PREVENT SKIN & EYE CONTACT. AVOID BREATHING HAZARDOUS
VAPORS. USE APPROVED RESPIRATOR FOR NUISANCE DUST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:JOINTLY APPROVED NIOSH/MSHA DUST & MIST
RESPIRATOR, ANY AIR-PURIFYING RESPIRATOR W/A HIGH-EFFICIENCY
PARTICULATE FILTER, ANY POWERED AIR-PURIFYING RESPIRATOR W/A DUST &
MIST FILTER/W/A HIGH EFFICIENCY PARTICULATE. ANY SCBA.
Ventilation:GENERAL MECHANICAL
Protective Gloves:IMPERVIOUS
Eye Protection:FACE SHIELD
Other Protective Equipment:SPLASH-PROOF/DUST-RESISTANT SAFETY GOGGLES,
IMPERVIOUS CLOTHING & EQUIPMENT, EYE WASH STATION IN WORK AREA.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING &
FOOTWEAR. MINIMIZE EXPOSURE IAW/GOOD HYGIENE PRACTICE.
Supplemental Safety and Health
PH: 6.7-7.7. SPILL PROC CONT'D: ADD ACTIVATED CARBON TO ABSORB
SUBSTANCE. USE DREDGES/LIFTS TO EXTRACT IMMOBILIZED MASSES OF
POLLUTION & PRECIPITATES.
================== Physical/Chemical Properties ==================
pH:(SUPP)
Solubility in Water:COMPLETE
Appearance and Odor:WHITE POWDER TO GRANULAR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BROMINTRIFLUORIDE/IODINE HEPTAFLUORIDE/POTASSIUM CHLORATE/METALS/STRONG
OXIDIZERS/SOIDUM HYPOCHLORITE
Hazardous Decomposition Products:BY THERMAL DECOMPOSITION: TOXIC FUMES
OF AMMONIA. OXIDES OF PHOSPHORUS
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF THIS PRODUCT/ITS RESIDUES IN
ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|