benzenesulfonic acid, ethenyl-, polymer with vinylbenzyltrimethylammonium hydroxide, polymer with water propyl alcohol, n-propanol
===================== Product Identification =====================
MSDS NAME:ION EXCHANGE RESINS
NIIN:00F051659
MSDS Number: CCFMN
=== Responsible Party ===
Company:O I CORP DBA O I ANALYTICAL
Address:CORNER OF GRAHAM AND WELLBORN RD
Box:9010
City:COLLEGE STATION
State:TX
ZIP:77842-5000
Country:US
Info Phone Num:409-690-1711
Emergency Phone Num:409-690-1711
CAGE:53810
=== Contractor Identification ===
Company:O I CORP DBA O I ANALYTICAL
Address:CORNER OF GRAHAM AND WELLBORN RD
Box:2980
City:COLLEGE STATION
State:TX
ZIP:77841
Country:US
CAGE:53810
============= Composition/Information on Ingredients =============
Name:BENZENESULFONIC ACID, ETHENYL-, POLYMER WITH
DIETHENYLBENZENE
CAS:39389-20-3
Fraction by Wt: 30-50%
Name:VINYLBENZYLTRIMETHYLAMMONIUM HYDROXIDE, POLYMER WITH
DIVINYLBENZENE
CAS:9017-79-2
Fraction by Wt: 30-50%
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 40-52%
Name:PROPYL ALCOHOL, N-PROPANOL
CAS:71-23-8
RTECS #:UH8225000
Fraction by Wt: 10-13%
Other REC Limits:200 PPM
OSHA PEL:500 MG/CUM
ACGIH TLV:492 MG/CUM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION.
======================= First Aid Measures =======================
First Aid:EYES/SKIN: FLUSH W/WATER FOR 15 MINS. INHALATION: REMOVE TO
FRESH AIR. GIVE CPR/OXYGEN IF NEEDED. OBTAIN MEDICAL ATTENTION IN
ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:CO2, DRY CHEMICAL, WATERSPRAY
Fire Fighting Procedures:WEAR SCBA & FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:AUTOIGNITION TEMP: 932F.
================== Accidental Release Measures ==================
Spill Release Procedures:FLOORS MAY BE SLIPPERY, EVEN WHEN DRY, DUE TO
BEADS. USE CARE TO AVOID FALLS. SWEEP UP & TRANSFER TO CONTAINES
FOR RECOVERY/DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T PACK COLUMN W/DRY ION EXCHANGE
RESIN. THE BEADS EXPAND WHEN WETTED, THE EXPANSION CAN CAUSE A
GLASS COLUMN TO SHATTER.
Other Precautions:NITRIC ACID & OTHER STRONG OXIDIZING AGENTS CAN CAUSE
EXPLOSIVE TYPE REACTIONS WHEN MIXED W/ION EXCHANGE RESINS. USE
PROPER EQUIPMENT TO PREVENT PRESSURE BUILDUP. BEFORE USE, CONSULT
KNOWLEDGEABLE SOU RCES IN HANDLING OF THESE MATERIALS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NEEDED FOR NORMAL OPERATIONS.
Ventilation:USE NORMAL ROOM VENTILATION.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:EYEWASH FACILITY
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:207F
Vapor Pres:17
Vapor Density:<1
Spec Gravity:1-1.3
Solubility in Water:MODERATE
Appearance and Odor:MOIST BEADS W/MILD AMMONIA & ALCOHOLIC ODOR.
Percent Volatiles by Volume:50-65
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CONCENTRATED NITRIC ACID & OXIDIZING AGENTS.
Stability Condition to Avoid:TEMP >392F
Hazardous Decomposition Products:STYRENE MONOMER, DIVINYLBENZENE,
ALKYLAMINE, OXIDES OF SULFUR, NITROGEN, CO2.
==================== Disposal Considerations ====================
Waste Disposal Methods:UNUSED RESIN MAY BE INCINERATED/LANDFILLED IN
FACILITIES IAW/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***