===================== Product Identification =====================
MSDS NAME:TRA-BOND 2129 HARDENER
NIIN:00N092050
Status Code:A
Kit Part:Y
MSDS Number: CJMBL
=== Responsible Party ===
Company:CIRCUIT REPAIR CORPORATION
Address:45 RESEARCH DRIVE
City:HAVERHILL
State:MA
ZIP:01832-1293
Country:US
Info Phone Num:978-374-5000
Emergency Phone Num:978-374-5000
Resp. Party Other MSDS Num.:SERIAL # C4275
CAGE:TO238
=== Contractor Identification ===
Company:CIRCUIT REPAIR CORPORATION
Address:45 RESEARCH DRIVE
Box:City:HAVERHILL
State:MA
ZIP:01832-1293
Country:US
Phone:978-374-5000
CAGE:TO238
============= Composition/Information on Ingredients =============
Name:DIETHYLENETRIAMINE; (REACTED MIXTURE BASED ON
DIETHYLENETRIMINE AND/OR SIMILAR ISOMERS AND HOMOLOGS)
CAS:111-40-0
RTECS #:IE1225000
Minumum % Wt:80.
Maxumum % Wt:100.
Other REC Limits:N/K
OSHA PEL:N/K
OSHA STEL:N/K
ACGIH TLV:4.2 MG/M3;1 PPM
ACGIH STEL:N/K
Name:OTHER INGREDIENTS (IF ANY) PER OSHA 1910.1200
(G)(2)(I)(C)(1) WHICH MAY COMPOSE LESS THAN 1% OF THE COMPOSITION,
&/OR WHICH ARE NON-HAZARDOUS/NOT LISTED ON THE MASSACHUSETTS
HAZARDOUS SUBSTANCE LIST
Minumum % Wt:0.
Maxumum % Wt:20.
Other REC Limits:N/K
OSHA PEL:N/K
OSHA STEL:N/K
ACGIH TLV:N/K
ACGIH STEL:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 (ORAL, RAT): > 500 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE, MOUTH OR SKIN CONTACT MAY
CAUSE SERIOUS BURNS. MATERIAL IS ALSO A STRONG SENSITIZER AND
SEVERE RESPIRATORY TRACT IRRITANT. EFFECTS COULD BE IRREVERSIBLE.
NO DELAYED, SUBCHRONIC OR CHRONIC TEST DATA ARE KNOWN.
Effects of Overexposure:SEE HEALTH HAZARDS.
======================= First Aid Measures =======================
Eyes: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MEDICAL
ATTENTION. SKIN: WASH WITH SOAP AND WATER. REMOVE CONTAMINATED
CLOTHING. DESTROY CONTAMINATED LEATHER. INHALATION: REMOVE TO FRESH
AIR. INGE STION: NO KNOWN ANTIDOTE. GIVE MILK OR WATER. DO NOT
INDUCE VOMITING IF SWALLOWED. GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>93.3C, 200.F
Extinguishing Media:DRY CHEMICALS, CHEMICAL FOAM, CARBON DIOXIDE,
WATER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . AVOID BREATHING SMOKE. ADDITION OF WATER MAY REDUCE
FLAME INTENSITY.
Unusual Fire/Explosion Hazard:TOXIC GASES MAY BE LIBERATED; HANDLE AS
COMBUSTIBLE. STORE IN COOL PLACE.
================== Accidental Release Measures ==================
Spill Release Procedures:PREVENT SKIN AND EYE CONTACT. SOAK UP
ABSORBENT MATERIAL, OR SCRAPE UP, AND TRANSFER TO DISPOSAL
CONTAINER. WIPE UP REMAINING RESIDUE WITH SOLVENTS, OBSERVING
SOLVENT FLAMMABILITY CAUTIONS, OR USE DET ERGENTS.
====================== Handling and Storage ======================
Handling and Storage Precautions:FOR INDUSTRIAL USE ONLY: MAY CAUSE
SENSITIZATION, IRRITATION, OR OTHER ALLERGIC RESPONSES. AVOID EYE
AND/OR SKIN CONTACT AND PROLONGED INHALATION OF VAPORS.
Other Precautions:STORE IN A COOL PLACE IN CLOSED CONTAINERS. FLAMMABLE
LIQUID, CLASS IC.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPROVED AIR-SUPPLIED, OR ORGANIC
CANISTER, MASK IN CONFINED AREAS.
Ventilation:LOCAL EXHAUST: RECOMMENDED. MECHANICAL (GENERAL):
RECOMMENDED. SPECIAL/OTHER: NOT APPLICABLE.
Protective Gloves:RUBBER OR PLASTIC DISPOSABLE GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AS REQUIRED TO PREVENT ALL BODY CONTACT.
ANSI APPROVED EMERGENCY EYEWASH AND DELUGE SHOWER .
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:>148.9C, 300.F
Vapor Pres:<1 MM HG
Vapor Density:>2 (AIR=1)
Spec Gravity:1.1 (H*2O=1)
Evaporation Rate & Reference:LOW (BUTYL ACETATE=1)
Solubility in Water:PARTIAL
Appearance and Odor:CLEAR, LIGHT AMBER, LOW VISCOSITY LIQUID;
AMMONIACAL ODOR.
Percent Volatiles by Volume:<1
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR OXIDIZING AGENTS, CHLORINATED COMPOUNDS.
Stability Condition to Avoid:AVOID HIGH TEMPERATURES.
Hazardous Decomposition Products:THERMAL PRODUCTS, NITROGEN OXIDES,
ALDEHYDES, AMMONIA, CARBON MONOXIDE, AND/OR CARBON DIOXIDE.
Conditions to Avoid Polymerization:CHLORINATED COMPOUNDS; EXOTHERMS
WHEN USED TO CURE EPOXY RESINS.
=================== Toxicological Information ===================
Toxicological Information:LD50 (DERMAL): > 1400 MG/KG. TLV-TWA 1 PPM.
CARCINOGEN: NONE. MUTAGEN: NONE. NEUROTOXIN: NONE. TERATOGEN: NONE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF AS HAZARDOUS WASTE ACCORDING TO
D.O.T. HAZARD CLASS. IF NOT REGULATED BY D.O.T. DISPOSE OF AS
ORM-E. DISPOSAL METHOD CAN BE LAND BURIAL OR CHEMICAL INCINERATION,
AS REGULATED BY ALL GOVERNM ENTAL AGENCIES. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS .
=================== MSDS Transport Information ===================
Transport Information:ORM-D CONSUMER COMMODITY.
===================== Regulatory Information =====================
Federal Regulatory Information:MSDS MAY BE USED TO COMPLY WITH OSHA'S
HAZARD COMMUNICATION STANDARD 29 CFR 1910.1200. TSCA STATUS: OK.
State Regulatory Information:
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.